Dummy drive carrier modules.

Two AC, 450W Power Supply/Cooling plug-in modules (see Figure 1–4)

One or two Serial ATA Control (SCM) Input/Output modules, dependent on configuration required: 1.5Gb internal operating speed with 1 Gb or 2Gb external operating speed. (See Figure 1–6).

1.1.1Enclosure Chassis

The chassis consists of a sheet metal enclosure assembly containing a Backplane PCB and module runner system This chassis assembly also includes an integral Operators (Ops) Panel, mounted at the rear.

The chassis assembly contains 16 drive bays at the front, each of which accommodates a plug-in drive carrier module. The 16 drive bays are arranged in 4 rows of 4 drives. At the rear, the chassis assembly contains the integral ops panel and four module bays to house two Power Supply/Cooling modules, one SCM I/O module, and one blank SCM module filler.

The Backplane PCB provides logic level signal and low voltage power distribution paths. Figure 1–2and Figure 1– 3 show front and rear views of an RS-1602 chassis respectively.

Note The DCS9550 1S1 Storage Expansion Unit is shipped in a preconfigured 42U rack configuration, except for the top three in the rack with the controllers or top two in an expansion rack. Refer to the IBM System Storage DCS9550 Installation, Service, and User Guide.

.

Figure 1–2Enclosure Chassis (Front)

Figure 1–3Enclosure Chassis (Rear)

.

2

IBM System Storage DCS9550 1S1 Storage Expansion Unit Installation, Service, and User Guide

Image 17
Contents IBM System Storage Page Preface International Standards Safety Guidelines Figure P-3PSU/Cooling Module Caution Label Figure P-5 PSU Safety Label Electric Shock Hazard Inside Class 1 Laser Product Avis de conformité à la réglementation d’Industrie Canada ESD Precautions Data Security Taiwan Contact Information How to Send Your Comments Page Page Contents Xiii IBM System Storage DCS9550 1S1 Storage Expansion Unit Introduction2Enclosure Chassis Front Enclosure ChassisMultiple Power Supply/Cooling Modules Power Supply/Cooling ModuleOperators Panel Ops Panel Indicators and SwitchesSCM Input/Output Module DCS9550 Controller Settings6SCM I/O Module 7SCM Front Panel as viewed from rear of Enclosure Sata Dual Path Transition Card Drive Status IndicatorsDrive Carrier Module Blank Modules Anti-tamper LocksDummy Carrier Modules Weight DimensionsAC Power 450W PSU PSU Safety and EMC ComplianceAirflow EnvironmentInterfaces SCM I/O Module SpecificationDrive Carrier Module Specification Software Enclosure Services SES Support This page is intentionally blank Planning Your Installation Installation1Module locations Enclosure Bay Numbering ConventionChassis Installation Parts Check List Enclosure Installation ProceduresPre-Requisites Rack Mounting Rail KitPower Supply/Cooling Module Procedure ProcedurePower Supply/Cooling Module Installation 2AC Power Supply/Cooling Module Handle in Open Position FC-AL Interface SCM I/O Module ConfigurationsInternal Loop Structures Unit 1-S Unit 2- S 7IBM System Storage DCS9550 Couplet Cabling SCM I/O Module InstallationDrive Enclosure Device Addressing Switch Function Recommended Definition Number SettingSwitch Function Recommended Row Column Drive ConfigurationDrive Carrier Installation Parts Check List 10Installing a Sata Drive Carrier Module Activating the Locks Engaging the Anti-tamper Locks13Activating the Anti-tamper Lock Power Cord Connection Parts Check ListGrounding Checks This page is intentionally blank Operation Power OnAC PSU Power Supply/Cooling Module LEDsLED Ops Panel LEDsDisk Drives LEDs Power DownStarting the Drives Emulation Limitations Initial Start-up Problems Faulty CordsLEDs Alarm Sounds On Power UpGreen Signal Good LED on SCM Not Lit Ops Panel LED SCM I/O Module LEDs Audible AlarmAudible Alarm Mute Power Supply/Cooling Faults TroubleshootingSystem Faults Thermal Control Power supplies FittedThermal Shutdown Thermal AlarmDrive Carrier Module Faults Replacing a Module Dealing with Hardware FaultsContinuous Operation During Replacement Inserting the Module 2Removing/Inserting an AC Power Supply/Cooling Module Removing the Module SCM I/O Module5Removing an SCM I/O Module 7SCM I/O Module Latch Operation Removal and ReplacementSpare Parts and Ancillary Items IBM MTM 1269-1S1 Sata Disk Chassis FRUsThis page is intentionally blank Glossary Page Index System LED For additional information, visit the web at Trademarks Page Page Readers’ Comments We’d Like to Hear from You Business Reply Mail Page SC30-9738-00