Introduction
• EMC | EN55022 (CISPR - A), FCC A |
1.4.7Interfaces
Drive support See drive carrier specification
Attachment 1 FCAL loop of 16 drives
Passive Backplane with 1 or 2 Loop Resiliency Circuit (SCM) I/O Modules.
Host Port: | Maximum external cable length: see |
SFP - SFP cables | manufacturer’s specification |
Expansion Port: SFP to SFP cables |
|
1.4.8SCM I/O Module Specification
Speed | 1.5Gb/s internal to each drive, 1Gb/s or 2Gb/s external |
| • Creates connections to a single loop of 16 drives |
| • 1 External FC loop with two SFP connections |
Mounting | Rear, single bays 3 and/or 4 (see Figure |
Connectors | • 2 x Expansion Ports: SFP connector |
| • 2 x Host Ports: SFP connector (2 per port) |
LED Functions |
|
FC Host Port 0 Signal | – Green: On: Incoming FC signal is GOOD |
Good | – Off: no connection or incorrect connection |
| – Flashing: Invalid SFP connection |
FC Host Port 1 Signal | – Green: On: Incoming FC signal is GOOD |
Good | – Off: no connection or incorrect connection |
| – Flashing: Invalid SFP connection |
Router Status | – Green: On: Storage Router Device Ready |
| – Off: Storage Router Device not ready or defective |
ESI/SCM Module Fault | – Amber: On: Fault present (also On when booting) |
| – Off: successful controller initialization |
Power Dissipation | 20W max. |
1.4.9Drive Carrier Module Specification
Please contact your supplier for details of approved drives.
Important Operating the DCS9550 1S1 Storage Expansion Unit with
warranty. |
|
Module Dimensions | Height 29.1mm Width 106.55mm Depth 44 mm |
Weight | 0.98kg (1.0” 36Gb drive) |
Transition card | mounting locations for ATA - SATA drives with transition card attached |
Operating Temperature | 5° C to 40° C (when installed in an |
| Supply/Cooling Modules) |
Power Dissipation | 17 Watts maximum |
12 | IBM System Storage DCS9550 1S1 Storage Expansion Unit Installation, Service, and User Guide |