IBM DCS9550 1S1 manual SCM I/O Module LEDs, Audible Alarm Mute

Page 56

Troubleshooting and Problem Solving

4.3.3SCM I/O Module LEDs

The SCM I/O module LEDs are shown in Table 4–3.

Table 4–3SCM I/O Module LEDs

LED

Definition

Color

Normal

Fault

 

 

 

Status

Status

 

 

 

 

 

FC Host Port 0

Incoming FC signal is GOOD

Green

On

 

Signal Good

No connection or incorrect connection

 

 

Off

 

Invalid SFP connection

 

 

Flashin

 

 

 

 

g

 

 

 

 

 

FC Host Port 1

Incoming FC signal is GOOD

Green

On

 

Signal Good

No connection or incorrect connection

 

 

Off

 

Invalid SFP connection

 

 

Flashin

 

 

 

 

g

 

 

 

 

 

Router Status

Storage Router Device Ready

Green

On

 

 

Storage Router Device not ready or

 

 

Off

 

defective

 

 

 

 

 

 

 

 

ESI/SCM

Fault present (also On when booting)

Amber

On

 

Module Fault

Successful controller initialization

 

 

Off

 

 

 

 

 

4.4Audible Alarm

The Ops Panel also includes an Audible Alarm which indicates when a fault state is present. The following conditions will activate the Audible Alarm:

Drive Fault

Fan Fault

Voltage out of range

Thermal overrun

System fault

4.4.1Audible Alarm Mute

When the Audible Alarm sounds, it may be muted by pressing the Alarm Mute push-button. Automatic muting will take place after two minutes if the mute switch is not manually operated. The Alarm Mute push-button is located above the indicators on the Ops Panel (see Figure 4–1). When the alarm is muted, it will continue to sound with short intermittent bleeps to indicate that a problem still exists. It will be silenced when all problems are cleared. (See also Thermal Shutdown states, Section 4.5.5).

LED Test Mode

The Alarm Mute push-button can also be used to test the LEDs on the Ops Panel. When the Mute push-button is held, all LEDs will be illuminated if there are no faults present.

IBM System Storage DCS9550 1S1 Storage Expansion Unit Installation, Service, and User Guide

41

Image 56
Contents IBM System Storage Page Preface International Standards Safety Guidelines Figure P-3PSU/Cooling Module Caution Label Figure P-5 PSU Safety Label Electric Shock Hazard Inside Class 1 Laser Product Avis de conformité à la réglementation d’Industrie Canada ESD Precautions Data Security Taiwan Contact Information How to Send Your Comments Page Page Contents Xiii Introduction IBM System Storage DCS9550 1S1 Storage Expansion UnitEnclosure Chassis 2Enclosure Chassis FrontPower Supply/Cooling Module Multiple Power Supply/Cooling ModulesOps Panel Indicators and Switches Operators PanelDCS9550 Controller Settings SCM Input/Output Module6SCM I/O Module 7SCM Front Panel as viewed from rear of Enclosure Sata Dual Path Transition Card Drive Status IndicatorsDrive Carrier Module Blank Modules Anti-tamper LocksDummy Carrier Modules Dimensions WeightAC Power 450W PSU PSU Safety and EMC ComplianceEnvironment AirflowInterfaces SCM I/O Module SpecificationDrive Carrier Module Specification Software Enclosure Services SES Support This page is intentionally blank Installation Planning Your InstallationEnclosure Bay Numbering Convention 1Module locationsEnclosure Installation Procedures Chassis Installation Parts Check ListPre-Requisites Rack Mounting Rail KitPower Supply/Cooling Module Procedure ProcedurePower Supply/Cooling Module Installation 2AC Power Supply/Cooling Module Handle in Open Position FC-AL Interface SCM I/O Module ConfigurationsInternal Loop Structures Unit 1-S Unit 2- S SCM I/O Module Installation 7IBM System Storage DCS9550 Couplet CablingSwitch Function Recommended Definition Number Setting Drive Enclosure Device AddressingSwitch Function Recommended Drive Configuration Row ColumnDrive Carrier Installation Parts Check List 10Installing a Sata Drive Carrier Module Engaging the Anti-tamper Locks Activating the LocksPower Cord Connection Parts Check List 13Activating the Anti-tamper LockGrounding Checks This page is intentionally blank Power On OperationPower Supply/Cooling Module LEDs AC PSUOps Panel LEDs LEDDisk Drives LEDs Power DownStarting the Drives Initial Start-up Problems Faulty Cords Emulation LimitationsLEDs Alarm Sounds On Power UpGreen Signal Good LED on SCM Not Lit Ops Panel LED SCM I/O Module LEDs Audible AlarmAudible Alarm Mute Power Supply/Cooling Faults TroubleshootingSystem Faults Power supplies Fitted Thermal ControlThermal Shutdown Thermal AlarmDrive Carrier Module Faults Replacing a Module Dealing with Hardware FaultsContinuous Operation During Replacement Inserting the Module 2Removing/Inserting an AC Power Supply/Cooling Module SCM I/O Module Removing the Module5Removing an SCM I/O Module Removal and Replacement 7SCM I/O Module Latch OperationIBM MTM 1269-1S1 Sata Disk Chassis FRUs Spare Parts and Ancillary ItemsThis page is intentionally blank Glossary Page Index System LED For additional information, visit the web at Trademarks Page Page Readers’ Comments We’d Like to Hear from You Business Reply Mail Page SC30-9738-00