IBM DCS9550 1S1 manual Engaging the Anti-tamper Locks, Activating the Locks

Page 44

Installation

Figure 2–12Installing an SATA Drive Carrier Module (3)

Note Removal is the reverse of this procedure (press on the latch to release the handle).

2.10.3Dummy Carrier Modules

Any unused drive bays must be fitted with a dummy carrier module.

2.10.4Engaging the Anti-tamper Locks

The anti-tamper locks are fitted in the drive carrier handles and are accessed through the small cutout in the latch section of the handle.

Drives are supplied with the locks set in the locked position.

2.10.4.1Activating the Locks

1Carefully insert the lock key provided into the cutout in the handle.

2Locate the key into its socket.

3Rotate the key in a clockwise direction until the indicator is visible in the aperture beside the key.

IBM System Storage DCS9550 1S1 Storage Expansion Unit Installation, Service, and User Guide

29

Image 44
Contents IBM System Storage Page Preface International Standards Safety Guidelines Figure P-3PSU/Cooling Module Caution Label Figure P-5 PSU Safety Label Electric Shock Hazard Inside Class 1 Laser Product Avis de conformité à la réglementation d’Industrie Canada ESD Precautions Data Security Taiwan Contact Information How to Send Your Comments Page Page Contents Xiii Introduction IBM System Storage DCS9550 1S1 Storage Expansion UnitEnclosure Chassis 2Enclosure Chassis FrontPower Supply/Cooling Module Multiple Power Supply/Cooling ModulesOps Panel Indicators and Switches Operators PanelDCS9550 Controller Settings SCM Input/Output Module6SCM I/O Module 7SCM Front Panel as viewed from rear of Enclosure Sata Dual Path Transition Card Drive Status IndicatorsDrive Carrier Module Blank Modules Anti-tamper LocksDummy Carrier Modules Dimensions WeightAC Power 450W PSU PSU Safety and EMC ComplianceEnvironment AirflowInterfaces SCM I/O Module SpecificationDrive Carrier Module Specification Software Enclosure Services SES Support This page is intentionally blank Installation Planning Your InstallationEnclosure Bay Numbering Convention 1Module locationsEnclosure Installation Procedures Chassis Installation Parts Check ListPre-Requisites Rack Mounting Rail KitPower Supply/Cooling Module Procedure ProcedurePower Supply/Cooling Module Installation 2AC Power Supply/Cooling Module Handle in Open Position FC-AL Interface SCM I/O Module ConfigurationsInternal Loop Structures Unit 1-S Unit 2- S SCM I/O Module Installation 7IBM System Storage DCS9550 Couplet CablingSwitch Function Recommended Definition Number Setting Drive Enclosure Device AddressingSwitch Function Recommended Drive Configuration Row ColumnDrive Carrier Installation Parts Check List 10Installing a Sata Drive Carrier Module Engaging the Anti-tamper Locks Activating the LocksPower Cord Connection Parts Check List 13Activating the Anti-tamper LockGrounding Checks This page is intentionally blank Power On OperationPower Supply/Cooling Module LEDs AC PSUOps Panel LEDs LEDDisk Drives LEDs Power DownStarting the Drives Initial Start-up Problems Faulty Cords Emulation LimitationsLEDs Alarm Sounds On Power UpGreen Signal Good LED on SCM Not Lit Ops Panel LED SCM I/O Module LEDs Audible AlarmAudible Alarm Mute Power Supply/Cooling Faults TroubleshootingSystem Faults Power supplies Fitted Thermal ControlThermal Shutdown Thermal AlarmDrive Carrier Module Faults Replacing a Module Dealing with Hardware FaultsContinuous Operation During Replacement Inserting the Module 2Removing/Inserting an AC Power Supply/Cooling Module SCM I/O Module Removing the Module5Removing an SCM I/O Module Removal and Replacement 7SCM I/O Module Latch OperationIBM MTM 1269-1S1 Sata Disk Chassis FRUs Spare Parts and Ancillary ItemsThis page is intentionally blank Glossary Page Index System LED For additional information, visit the web at Trademarks Page Page Readers’ Comments We’d Like to Hear from You Business Reply Mail Page SC30-9738-00