IBM C4C 4.51 3.5-inch Small FF 38-pin Unitized, SSA manual Capacity Equations, For Each Notch

Page 13

U S E R RESPONSIBLE F O R V E R I F Y I N G VERSION A N D COMPLETENESS

O E M F U N C T I O N A L S P E C I F I C A T I O N U L T R A S T A R X P ( D F H C ) SSA M O D E L S 1.12/2.25 G B - 1.0" H I G H

 

 

 

 

 

 

 

 

 

 

 

Notch #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User bytes /

1

 

2

 

3

 

4

 

5

 

 

6

 

7

 

8

 

9

 

10

logical block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

256

 

216

 

216

 

216

 

202

 

195

 

 

180

 

180

 

180

 

180

 

162

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

512

 

135

 

135

 

130

 

126

 

120

 

 

115

 

112

 

108

 

105

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

520

 

128

 

128

 

128

 

123

 

115

 

 

112

 

108

 

105

 

102

 

99

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

522

 

128

 

128

 

128

 

122

 

115

 

 

112

 

108

 

105

 

102

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

524

 

128

 

128

 

128

 

120

 

115

 

 

112

 

108

 

105

 

102

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

528

 

128

 

128

 

126

 

120

 

112

 

 

112

 

108

 

105

 

101

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600

 

115

 

115

 

115

 

110

 

102

 

 

101

 

97

 

90

 

90

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

688

 

102

 

102

 

102

 

98

 

90

 

 

90

 

90

 

90

 

81

 

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

744

 

96

 

96

 

96

 

90

 

90

 

 

90

 

81

 

78

 

77

 

73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table

1. Gross sectors per track for several block lengths

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C4x Models

 

 

C2x Models

 

 

C1x Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User bytes /

 

formatted

 

 

logical

 

formatted

 

logical

 

 

formatted

 

 

logical

logical block

 

capacity

 

 

blocks /

 

capacity

 

blocks /

 

 

capacity

 

 

blocks /

 

 

 

(bytes)

 

 

drive

 

(bytes)

 

drive

 

 

(bytes)

 

 

 

drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

256

 

3,654,540,800

14,275,550

1,826,312,448

 

 

7,134,033

912,135,680

 

 

3,563,030

 

 

 

 

 

 

 

 

 

 

 

 

 

 

512

 

4,512,701,440

8,813,870

2,255,098,368

 

 

4,404,489

1,126,337,536

 

 

2,199,878

 

 

 

 

 

 

 

 

 

 

 

 

 

 

520

 

4,375,536,880

8,414,494

2,186,554,760

 

 

4,204,913

1,092,119,600

 

 

2,100,230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

522

 

4,374,300,492

8,379,886

2,185,931,898

 

 

4,187,609

1,091,803,716

 

 

2,091,578

 

 

 

 

 

 

 

 

 

 

 

 

 

 

524

 

4,385,878,952

8,369,998

2,191,716,460

 

 

4,182,665

1,094,691,544

 

 

2,089,106

 

 

 

 

 

 

 

 

 

 

 

 

 

 

528

 

4,408,629,984

8,349,678

2,203,082,640

 

 

4,172,505

1,100,365,728

 

 

2,084,026

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600

 

4,512,402,000

7,520,670

2,254,925,400

 

 

3,758,209

1,126,282,800

 

 

1,877,138

 

 

 

 

 

 

 

 

 

 

 

 

 

 

688

 

4,604,578,976

6,692,702

2,300,969,904

 

 

3,344,433

1,149,310,880

 

 

1,670,510

 

 

 

 

 

 

 

 

 

 

 

 

 

 

744

 

4,675,830,192

6,284,718

2,336,559,528

 

 

3,140,537

1,167,099,408

 

 

1,568,682

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table

2. User capacity for several block lengths

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.1.1 Capacity Equations

2.1.1.1 For Each Notch

The next group of equations must be calculated separately for each notch.

ub/ lba

user bytes/ sector (ub/ sct) =

sct/ lba

user sectors/cyl (us/cyl) = (sct/trk)(trk/cyl) - spr/cyl

spares/notch (spr/nch) = (spr/cyl)(ucyl)

Note: Add lcspr to the equation above for the notch closest to the inner diameter (#10).

user sectors/notch (us/nch) = (us/cyl)(ucyl)

Note: Subtract lcspr from the equation above for the notch closest to the inner diameter (#10).

Source filename=SPECS

I B M Corporation

Page 13 of 87

Image 13
Contents Form Factor Disk Drive Version BM Corporation Preface Source filename=STSSHEXT When Operating Limits ReliabilityContaminants Acoustic Levels Source filename=STSSHEXT General Features FeaturesInterface Controller Features DescriptionModels Reliability FeaturesGeneral SpecificationsSectors/logical block sct/lba User bytes/sector ub/sctUser bytes/logical block ub/lba Sectors/track sct/trkFor Each Notch Capacity EquationsFor Entire Drive 1 C1x Models Power Requirements by ModelInput Voltage + 5 Volts Supply + 1 2 Volts SupplyExample 3. Power Calculation Power Calculation ExamplesExample 1. Calculate the mean 12 volt average current Example 4. Calculate the 12 volt peak current Things to check when measuring 12 V supply currentVolt current during read/write operations C1x Models Typical 12 volt current C1x Models Typical 12 volt spin-up current C1x Models 2 C2x Models Power Calculation Examples Example 4. Calculate the 12 volt peak current Volt current during read/write operations C2x Models Typical 12 volt current C2x Models Typical 12 volt spin-up current C2x Models 3 C4x Models Power Calculation Examples Example 4. Calculate the 12 volt peak current Volt current during read/write operations C4x Models Typical 12 volt current C4x Models Typical 12 volt spin-up current C4x Models CxB Models Power supply methods4.2 DC/DC Converter Hot plug/unplug support Grounding Requirements of the Disk EnclosureM Corporation Event Nominal Maximum Bring-up Sequence and Stop TimesBring-up Sequence Times and Stop Time for C2x Models Source filename=PERFORM Environment Definition PerformanceWorkload Definition # of segments Ub/lba +Sequential Command Execution TimeRandom Basic Component DescriptionsData Transfer to/from Disk Data Transfer to/from SSA Link CommentsTheoretical Data Sector Transfer Rate Approximating Performance for Different EnvironmentsWhen Write Caching is Enabled When Read Caching is EnabledWhen Adaptive Caching is Enabled When Read-ahead is EnabledFor Queued Commands When No Seek is RequiredReordered Commands Back-To-Back CommandsCylinder to Cylinder Skew SkewTrack to Track Skew Idle Time Functions Servo Bias Measurements Servo Run Out MeasurementsPredictive Failure Analysis Channel CalibrationSave Logs and Pointers Command Timeout LimitsDisk Sweep M Corporation Mechanical Weight and DimensionsSmall Form Factor Models CxC ClearancesDimensions are in millimeters Location of Side Mounting Holes of C4C Models Source filename=MECHANIC Unitized Connector Locations Source filename=MECHANIC Carrier Models CxB Dimensions CxB Models M Corporation Handle Docking and Ejection System Auto-docking Assembly Side Rails Side Rail Positioning E D Locations front view CxB Models M Corporation Electrical Connector and Indicator LocationsElectrical Interface SSA Unitized ConnectorPin Carrier ConnectorRow Option Pins and Indicators SSA Link Electrical CharacteristicsSSA Link Cable Device Fault Pin/Indicator Option Port Pin Device Activity Pin/Indicator Option Port PinWrite Protect Option Port Pin Ground long Option Port PinEarly Power Off Warning or Power Fail Power Port Pin Front Jumper Connector12 12V Charge and 5V Charge Power Port pin 1 Programmable pin 1 Option Port PinSpindle Synchronization Over Sync Hard-wire M Corporation Source filename=RELIABLE Seek Error Rate Error DetectionPower On Hours Examples ReliabilityUseful Life Power on/off cyclesMaximum on/off cycles Product LifeMean Time Between Failure *MTBF Install Defect FreeSpql Shipped product quality level Sample Failure Rate ProjectionsConnector Insertion Cycles Periodic MaintenanceInstall Defect Free percentage Percent ESD ProtectionOperating Limits Temperature Measurement PointsP F E T Maximum ReliabilityVibration and Shock Temperature Measurement Points for all Models bottom viewOutput Vibration Limits Drive Mounting GuidelinesOperating Vibration V4S Nonoperating VibrationOperating Shock ContaminantsNonoperating Shock Acoustic Levels Upper Limit Sound Power Requirements Bels for C4x ModelsSource filename=STANDARD Standards SafetyElectromagnetic Compatibility EMC M Corporation Serial Storage Architecture S S a P H Transport Bibliography