3.4.1 For Different Transfer Sizes

The primary performance change due to a change of transfer size is the Data Transfer to/from Disk param- eter. See 3.3.1, “Basic Component Descriptions” onpage 40 for an explanation of the calculation of this parameter.

The Command Execution Overhead may also change if the transfer size is reduced to the point where certain internal control functions can no longer be overlapped with either the SSA Link or Disk data transfer.

For example, a short read may incur up to .65ms extra overhead if the Data Ready/Reply exchange does not overlap the disk transfer.

3.4.2 When Read Caching is Enabled

For read commands with Read Caching Enabled Command Execution time can be approximated by deleting Seek, Latency, and Data Transfer to/from Disk components if all of the requested data is available in a cache segment (cache hit). Command Execution Overhead increases by approximately .1ms in this case as there is no overlap with seek/latency.

When some, but not all, of the requested data is available in a cache segment (partial cache hit) Data Transfer to/from Disk will be reduced but not eliminated. Seek and Latency may or may not be reduced depending upon the location of requested data not in the cache and location of the read/write heads at the time the command was received.

The contribution of the Data Transfer to/from SSA link to the Command Execution time may increase since a larger, or entire, portion of the transfer may no longer be overlapped with the components that were reduced.

3.4.3 When Write Caching is Enabled

For write commands with the Write Caching Enabled (WCE) Mode parameter bit set, Command Execution time can be approximated by deleting Seek, Latency, and Data Transfer to/from Disk components. The contribution of the Data Transfer to/from SSA link to the Command Execution time may increase since a larger, or entire, portion of the transfer may no longer be overlapped with the components that were reduced. The reduced times effectively are added to the Post Command Processing Time.

Command completion status is returned when data is completely stored in the buffer. The time to transfer this group of data to the disk will be added to the performance of any next command that was in the queue.

3.4.4 When Adaptive Caching is Enabled

The Adaptive Caching feature attempts to increase Read Cache hit ratios by monitoring workload and adjusting cache control parameters, normally determined by the using system via the Mode Parameters, with algorithms using the collected workload information.

3.4.5 When Read-ahead is Enabled

If read-ahead is active, the service time is affected in several ways:

If the data requested by a read command is all in the data buffer already, the command can be serviced very quickly.

If the beginning of the requested data is in the buffer, and the read-ahead is still in progress, data transfer

Page 44 of 87

I B M Corporation

Source filename=PERFORM

Image 44
Contents Form Factor Disk Drive Version BM Corporation Preface Source filename=STSSHEXT When Reliability Operating LimitsContaminants Acoustic Levels Source filename=STSSHEXT Features General FeaturesInterface Controller Features DescriptionReliability Features ModelsSpecifications GeneralUser bytes/sector ub/sct Sectors/logical block sct/lbaUser bytes/logical block ub/lba Sectors/track sct/trkCapacity Equations For Each NotchFor Entire Drive Power Requirements by Model 1 C1x ModelsInput Voltage + 5 Volts Supply + 1 2 Volts SupplyExample 1. Calculate the mean 12 volt average current Power Calculation ExamplesExample 3. Power Calculation Things to check when measuring 12 V supply current Example 4. Calculate the 12 volt peak currentVolt current during read/write operations C1x Models Typical 12 volt current C1x Models Typical 12 volt spin-up current C1x Models 2 C2x Models Power Calculation Examples Example 4. Calculate the 12 volt peak current Volt current during read/write operations C2x Models Typical 12 volt current C2x Models Typical 12 volt spin-up current C2x Models 3 C4x Models Power Calculation Examples Example 4. Calculate the 12 volt peak current Volt current during read/write operations C4x Models Typical 12 volt current C4x Models Typical 12 volt spin-up current C4x Models 4.2 DC/DC Converter Power supply methodsCxB Models Grounding Requirements of the Disk Enclosure Hot plug/unplug supportM Corporation Bring-up Sequence and Stop Times Event Nominal MaximumBring-up Sequence Times and Stop Time for C2x Models Source filename=PERFORM Performance Environment DefinitionWorkload Definition # of segments Ub/lba +Command Execution Time SequentialRandom Basic Component DescriptionsData Transfer to/from Disk Comments Data Transfer to/from SSA LinkApproximating Performance for Different Environments Theoretical Data Sector Transfer RateWhen Read Caching is Enabled When Write Caching is EnabledWhen Adaptive Caching is Enabled When Read-ahead is EnabledWhen No Seek is Required For Queued CommandsReordered Commands Back-To-Back CommandsTrack to Track Skew SkewCylinder to Cylinder Skew Idle Time Functions Servo Run Out Measurements Servo Bias MeasurementsPredictive Failure Analysis Channel CalibrationDisk Sweep Command Timeout LimitsSave Logs and Pointers M Corporation Weight and Dimensions MechanicalSmall Form Factor Models CxC ClearancesDimensions are in millimeters Location of Side Mounting Holes of C4C Models Source filename=MECHANIC Unitized Connector Locations Source filename=MECHANIC Carrier Models CxB Dimensions CxB Models M Corporation Handle Docking and Ejection System Auto-docking Assembly Side Rails Side Rail Positioning Electrical Connector and Indicator Locations E D Locations front view CxB Models M CorporationSSA Unitized Connector Electrical InterfaceCarrier Connector PinRow SSA Link Cable SSA Link Electrical CharacteristicsOption Pins and Indicators Device Activity Pin/Indicator Option Port Pin Device Fault Pin/Indicator Option Port PinWrite Protect Option Port Pin Ground long Option Port PinFront Jumper Connector Early Power Off Warning or Power Fail Power Port Pin12 12V Charge and 5V Charge Power Port pin 1 Programmable pin 1 Option Port PinSpindle Synchronization Over Sync Hard-wire M Corporation Source filename=RELIABLE Error Detection Seek Error RatePower On Hours Examples ReliabilityPower on/off cycles Useful LifeMaximum on/off cycles Product LifeInstall Defect Free Mean Time Between Failure *MTBFSpql Shipped product quality level Sample Failure Rate ProjectionsPeriodic Maintenance Connector Insertion CyclesInstall Defect Free percentage Percent ESD ProtectionTemperature Measurement Points Operating LimitsMaximum Reliability P F E TTemperature Measurement Points for all Models bottom view Vibration and ShockOperating Vibration Drive Mounting GuidelinesOutput Vibration Limits Nonoperating Vibration V4SNonoperating Shock ContaminantsOperating Shock Upper Limit Sound Power Requirements Bels for C4x Models Acoustic LevelsSource filename=STANDARD Electromagnetic Compatibility EMC SafetyStandards M Corporation Bibliography Serial Storage Architecture S S a P H Transport