IBM C4C 4.51 3.5-inch Small FF 38-pin Unitized, SSA manual Error Detection, Data Reliability

Page 73

U S E R RESPONSIBLE F O R V E R I F Y I N G VERSION A N D COMPLETENESS

O E M F U N C T I O N A L S P E C I F I C A T I O N U L T R A S T A R X P ( D F H C ) SSA M O D E L S 1.12/2.25 G B - 1.0" H I G H

6.0 Reliability

Note: The reliability projections are based on the conditions stated below. All of the SSA models will meet the projections as long as reliability operating conditions are not exceeded.

6.1

Error Detection

 

Error reporting ³ 99%

All detected errors excluding interface and BATs #1 (Basic Assur-

 

 

ance Test) errors

Error detection ³ 99%

 

FRU isolation = 100%

T o the device when the "Recommended Initiator Error Recovery

 

 

Procedures" in the Ultrastar X P ( D F H C ) S S A Models Interface

 

 

Specification are followed.

 

 

N o isolation to sub-assemblies within the device are specified.

 

 

 

6.2

Data Reliability

 

Probability of not recovering data Recoverable read errors

10 in 1015 bits read

10 in 1013 bits read (measured at nominal D C conditions and room environment with default error recovery — Q P E **)

Probability of miscorrecting unrecoverable data

Note: Eighteen bytes of E C C and two bytes of L R C are provided for each data block.

6.3 Seek Error Rate

The drives are designed to have less than 10 errors in 10,000,000 seeks. In the field, a seek error rate of 40 in 100, 000 seeks will trip P F A (Predictive Failure Analysis) error.

The drives are designed to achieve Soft Seek Error rate of 1 error in 100,000,000 seeks.

6.4 Power On Hours Examples:

Maximum power on hours (with minimum power on/off cycles)

43,800 hours for life based on:

-5 Power on/off cycles per month

-730 power on hours per month

Nominal power on hours (with nominal power on/off cycles)

30,000 hours for life based on:

** Refer to Ultrastar X P ( D F H C ) S S A Models Interface Specification for the definition of Q P E (Qualify Post Error).

Source filename=RELIABLE

I B M Corporation

Page 73 of 87

Image 73
Contents Form Factor Disk Drive Version BM Corporation Preface Source filename=STSSHEXT When Operating Limits ReliabilityContaminants Acoustic Levels Source filename=STSSHEXT General Features FeaturesInterface Controller Features DescriptionModels Reliability FeaturesGeneral SpecificationsSectors/logical block sct/lba User bytes/sector ub/sctUser bytes/logical block ub/lba Sectors/track sct/trkFor Each Notch Capacity EquationsFor Entire Drive 1 C1x Models Power Requirements by ModelInput Voltage + 5 Volts Supply + 1 2 Volts SupplyExample 3. Power Calculation Power Calculation ExamplesExample 1. Calculate the mean 12 volt average current Example 4. Calculate the 12 volt peak current Things to check when measuring 12 V supply currentVolt current during read/write operations C1x Models Typical 12 volt current C1x Models Typical 12 volt spin-up current C1x Models 2 C2x Models Power Calculation Examples Example 4. Calculate the 12 volt peak current Volt current during read/write operations C2x Models Typical 12 volt current C2x Models Typical 12 volt spin-up current C2x Models 3 C4x Models Power Calculation Examples Example 4. Calculate the 12 volt peak current Volt current during read/write operations C4x Models Typical 12 volt current C4x Models Typical 12 volt spin-up current C4x Models CxB Models Power supply methods4.2 DC/DC Converter Hot plug/unplug support Grounding Requirements of the Disk EnclosureM Corporation Event Nominal Maximum Bring-up Sequence and Stop TimesBring-up Sequence Times and Stop Time for C2x Models Source filename=PERFORM Environment Definition PerformanceWorkload Definition # of segments Ub/lba +Sequential Command Execution TimeRandom Basic Component DescriptionsData Transfer to/from Disk Data Transfer to/from SSA Link CommentsTheoretical Data Sector Transfer Rate Approximating Performance for Different EnvironmentsWhen Write Caching is Enabled When Read Caching is EnabledWhen Adaptive Caching is Enabled When Read-ahead is EnabledFor Queued Commands When No Seek is RequiredReordered Commands Back-To-Back CommandsCylinder to Cylinder Skew SkewTrack to Track Skew Idle Time Functions Servo Bias Measurements Servo Run Out MeasurementsPredictive Failure Analysis Channel CalibrationSave Logs and Pointers Command Timeout LimitsDisk Sweep M Corporation Mechanical Weight and DimensionsSmall Form Factor Models CxC ClearancesDimensions are in millimeters Location of Side Mounting Holes of C4C Models Source filename=MECHANIC Unitized Connector Locations Source filename=MECHANIC Carrier Models CxB Dimensions CxB Models M Corporation Handle Docking and Ejection System Auto-docking Assembly Side Rails Side Rail Positioning E D Locations front view CxB Models M Corporation Electrical Connector and Indicator LocationsElectrical Interface SSA Unitized ConnectorPin Carrier ConnectorRow Option Pins and Indicators SSA Link Electrical CharacteristicsSSA Link Cable Device Fault Pin/Indicator Option Port Pin Device Activity Pin/Indicator Option Port PinWrite Protect Option Port Pin Ground long Option Port PinEarly Power Off Warning or Power Fail Power Port Pin Front Jumper Connector12 12V Charge and 5V Charge Power Port pin 1 Programmable pin 1 Option Port PinSpindle Synchronization Over Sync Hard-wire M Corporation Source filename=RELIABLE Seek Error Rate Error DetectionPower On Hours Examples ReliabilityUseful Life Power on/off cyclesMaximum on/off cycles Product LifeMean Time Between Failure *MTBF Install Defect FreeSpql Shipped product quality level Sample Failure Rate ProjectionsConnector Insertion Cycles Periodic MaintenanceInstall Defect Free percentage Percent ESD ProtectionOperating Limits Temperature Measurement PointsP F E T Maximum ReliabilityVibration and Shock Temperature Measurement Points for all Models bottom viewOutput Vibration Limits Drive Mounting GuidelinesOperating Vibration V4S Nonoperating VibrationOperating Shock ContaminantsNonoperating Shock Acoustic Levels Upper Limit Sound Power Requirements Bels for C4x ModelsSource filename=STANDARD Standards SafetyElectromagnetic Compatibility EMC M Corporation Serial Storage Architecture S S a P H Transport Bibliography