U S E R RESPONSIBLE F O R V E R I F Y I N G VERSION A N D COMPLETENESS
O E M F U N C T I O N A L S P E C I F I C A T I O N U L T R A S T A R X P ( D F H C ) SSA M O D E L S 1.12/2.25 G B - 1.0" H I G H
Pin |
| SSA PORT | SSA PORT |
| OPTION PORT | POWER PORT | |
|
|
|
|
|
|
|
|
1 |
| + Line Out | + Line Out |
| - M T M | + | 12V Charge |
|
|
|
|
|
| (long) | |
|
|
|
|
|
|
|
|
2 |
| - Line Out | - Line Out |
| - Auto Start | + | 5V Charge (long) |
|
|
|
|
|
|
| |
3 |
| Gnd (long) | Gnd (long) |
| - Sync | Gnd (long) | |
|
|
|
|
|
|
|
|
4 |
| Gnd (long) | Gnd (long) |
| - Write Protect | + | 12V |
|
|
|
|
|
|
|
|
5 |
| - Line In | - Line In |
| Gnd (long) | + | 12V |
|
|
|
|
|
|
|
|
6 |
| + Line In | + Line In |
| - Device Activity | + | 12V |
|
|
|
|
|
|
| |
7 |
| N / A | N / A |
| + 5V | Gnd (long) | |
|
|
|
|
|
|
| |
8 |
| N / A | N / A |
| - Device Fault | Gnd (long) | |
|
|
|
|
|
|
|
|
9 |
| N / A | N / A |
| Programmable 1 | + | 5V |
|
|
|
|
|
|
|
|
10 |
| N / A | N / A |
| Programmable 2 | + | 5V |
|
|
|
|
|
|
| |
11 |
| N / A | N / A |
| N / A | - Power Fail | |
|
|
|
|
|
|
| |
12 |
| N / A | N / A |
| N / A | G N D (long) | |
|
|
|
|
|
|
|
|
13 |
| N / A | N / A |
| N / A | + | 3.3V |
|
|
|
|
|
|
|
|
14 |
| N / A | N / A |
| N / A | + | 3.3V |
|
|
|
|
|
|
| |
15 |
| N / A | N / A |
| N / A | Gnd (long) | |
|
|
|
|
|
|
| |
16 |
| N / A | N / A |
| N / A | Gnd (long) | |
|
|
|
|
|
|
|
|
Table | 11. Electrical Connector Contact Assignments — CxC | Models |
|
|
5.2 Carrier Connector
Electrical connections for CxB models are provided by a single 128 pin connector mounted on the rear of the drive (see Figure 15 on page 58 for location). Connections are provided for two SSA ports, fault sensors and indicators, and power. The receptacle used is a 4× 32, female contact, B E R G H P C connector, IBM part number 99F9429. Refer to Figure 20 and Table 12 on page 65 for contact assignments.
Figure 20. Carrier Interface Receptacle
Page 64 of 87 | I B M Corporation |