Making Frame Relay Connections
Making Frame Relay Connections
This section outlines how to establish Frame Relay service by setting up a universal frame module (UFM) or a Frame Relay module (FRM). The information includes details for T1, E1, HSSI, V.35, and X.25 interfaces. Detailed descriptions of the Frame Relay commands appear in the Cisco WAN Switching Command Reference. Specific cabling requirements for the UFI back cards on the
Maximum Connections Per Port with Signalling Protocols
For any Frame Relay card set that has a maximum frame length of 4510 bytes, the type of signaling protocol you can (optionally) specify with cnffrport results in a limit on the number of connections per physical or logical port. The maximum number of connections per port for each protocol is:
•
•
•
For Annex A: 899
For Annex D: 899
For StrataLMI: 562
Neither addcon nor cnffrport prevents you from adding more than the maximum number of connections on a port. (You might, for example, use cnffrport to specify an LMI when too many connections for that particular LMI already exist.) If the number of connections is exceeded for a particular LMI, the LMI does not work on the port, the full status messages that result are discarded, and LMI timeouts occur on the port. A port failure results and also subsequently leads to
Setting Up Frame Relay on a UFM
Channelized and unchannelized versions of the UFM card sets exit. The channelized front cards
The back cards have the following terminations:
•
•
•
•
•
•
The
The
The
The
The
The
If the installation includes
Y-Cable Redundancy on the UFMs
Redundancy for a Frame Relay port is possible with a second card set and the appropriate
Refer to the cabling description in the