Cisco Systems IGX 8400 Series manual Making Alarm Relay Output Connections

Page 35

Making Frame Relay Connections

Step 10 Determine which Frame Relay class number to use when you add connections to a port. To see the parameters that a class specifies, use the dspfrcls command. To modify parameters in a class, use the cnffrcls.

Step 11 Add connections to the port by using the addcon command. Enter the slot number and specify a DLCI for each end of the connection.

Step 12 For an individual connection, you can configure bandwidth parameters or enable

ForeSight (if purchased) by using the cnffrcon.

Step 13 Optionally, you can set the channel priority by using the Configure Channel Priority cnfchpri command. Normally, the system-default priority is adequate.

Commands for T1/E1 Frame Relay

To specify logical ports on a T1 or E1 interface, use addfrport. The addfrport command assigns a logical port number to a group of one or more DS0s/timeslots. The slot number and the lowest number in the user-specified DS0/timeslot group form the logical port number. Use the logical port number to activate a port (upfrport), add connections (addcon), or display statistics (dspportstats). For example, after you add logical port 14.1-6 (6 DS0s/timeslots) with addfrport, you activate (or up) this logical port by entering “ upfrport 14.1.” Use dspfrport to display logical ports.

Deleting a Frame Relay Port

Executing delfrport dissolves any groups of DS0s/timeslots and unassigns all DS0s/timeslots on the logical port. To delete a logical port:

Step 1 Delete any connections on the port with delcon.

Step 2 Delete the logical port with delfrport.

Step 3 You can deactivate the logical port with dnfrport.

Step 4 You can deactivate the physical line with dnln.

Making Alarm Relay Output Connections

To install an alarm relay module (ARM) card set:

Step 1 At the back of the IGX node, identify the slot where the ARI card is to reside.

Step 2 Install the ARM in the front slot and use the card extractors to help secure card.

Step 3 Install the ARI in the corresponding back slot. Use the extractor handles to help secure the card then tighten the captive screws by hand.

Step 4 Note that the FAIL LED on the ARM is off. The ACTIVE LED is also off.

Step 5 Attach a 22- or 24-gauge cable with the appropriate number of pairs to a male DB-37 connector at one end. Typically, a 12-pair cable is adequate. Connect this cable to the DB-37 connector on the ARI and tighten the captive screws.

See the section “Initial Startup of the IGX” on page 46, when the system is ready for power.

The steps that follow show how to set up an ARM card set after the physical installation is complete. This is done from the IGX control terminal or the Cisco WAN Manager workstation. For details on each command used, refer to the Cisco WAN Switching Command Reference.

Step 1 Verify that the node is equipped with the proper ARM front card and ARI back card by using the dspcds command. This will show in which slot they are located.

Card Installation and Node Startup 3-35

Image 35
Contents Preparing the Cards Card Installation and Node StartupPreparing the Cards IGX 8410 Cards, Front View IGX 8410 Cards, Back View IGX 8420 Card Shelf, Front View IGX 8430 Back View Inserting Modules Inserting the CardsHssi Making Signal ConnectionsBringing Up a UXM-E Trunk Connecting TrunksSetting Up a UXM-E Cable Management Dspcds Inverse Multiplexing over ATM on TrunksAdding Links to an IMA Feeder Group Adding an IMA Feeder TrunkRemoving Links from an IMA Feeder Group UXM-E Inverse Multiplexing ATM IMA LinesConnecting an NTM E1 or Subrate Trunk Connecting an NTM T1 or Y1 TrunkBringing Up a UXM-E in UNI or NNI Port Mode Connecting a CVM to a T1 or J1 Line Installing Voice CardsTDM Transport on the CVM Connecting a CVM to an E1 Line or a Subrate TrunkConnecting a UVM to T1 Lines Pass-Through and Standard External UVM T1 Cabling Connecting a UVM to E1 Lines Pass-Through and Standard External UVM E1 Cabling Connecting a UVM to J1 Lines 10 Pass-Through and Standard External UVM J1 Cabling 11 SDI and LDI Faceplates Making Serial Data ConnectionsConfiguring the Port Modes of the HDM Back Cards HDM and LDM Redundancy Configuring the Mode of an LDI Port13 Connecting a DTE or DCE Adapter Cable to an LDI Cable Redundancy on the UFMs Maximum Connections Per Port with Signalling ProtocolsSetting Up Frame Relay on a UFM Making Frame Relay Connections14 Y-Cable Redundancy with Single and Dual-Port Cabling Setting Up Frame Relay Ports and Connections UFM Connecting UFM CablingDeleting a Frame Relay Port Setting Up Frame Relay on an FRMCommands for T1/E1 Frame Relay Port Mode Selection for V.35 Frame Relay Card Redundancy 15 Setting the Port Mode DTE/DCE on an FRISetting Up Frame Relay Ports and Connections FRM Making Alarm Relay Output Connections 36Cisco IGX 8400 Series Installation and Configuration Attaching Peripherals Connecting a Single Network Management StationMaking External Clock Connections 16 Connecting the Control Terminal 17 LAN Connection to SCM LAN Connection for the Network Management StationConfiguring the LAN Port D2.cb1 LAN superuser IGX 42Cisco IGX 8400 Series Installation and Configuration Connecting a Network Management Station to Multiple Networks 20 Connecting a Network Printer Connecting the Printer21 Connecting Modems to an IGX Node Connecting a ModemInitial Startup of the IGX Connecting the Power Supply MonitorFail screen looks like this NPM Startup Diagnostic TestInspecting Status Lights Card Self TestIGX Configuration Summary Checking the Power Supplies AC Systems50Cisco IGX 8400 Series Installation and Configuration Interworking Connections in a Tiered Network Configuring an IGX Switch to Be an Interface ShelfConverting a Routing Node to an Interface Shelf Adding Connections in a Tiered Network through the CLI