Making Frame Relay Connections
Step 10 Determine which Frame Relay class number to use when you add connections to a port. To see the parameters that a class specifies, use the dspfrcls command. To modify parameters in a class, use the cnffrcls.
Step 11 Add connections to the port by using the addcon command. Enter the slot number and specify a DLCI for each end of the connection.
Step 12 For an individual connection, you can configure bandwidth parameters or enable
ForeSight (if purchased) by using the cnffrcon.
Step 13 Optionally, you can set the channel priority by using the Configure Channel Priority cnfchpri command. Normally, the
Commands for T1/E1 Frame Relay
To specify logical ports on a T1 or E1 interface, use addfrport. The addfrport command assigns a logical port number to a group of one or more DS0s/timeslots. The slot number and the lowest number in the
Deleting a Frame Relay Port
Executing delfrport dissolves any groups of DS0s/timeslots and unassigns all DS0s/timeslots on the logical port. To delete a logical port:
Step 1 Delete any connections on the port with delcon.
Step 2 Delete the logical port with delfrport.
Step 3 You can deactivate the logical port with dnfrport.
Step 4 You can deactivate the physical line with dnln.
Making Alarm Relay Output Connections
To install an alarm relay module (ARM) card set:
Step 1 At the back of the IGX node, identify the slot where the ARI card is to reside.
Step 2 Install the ARM in the front slot and use the card extractors to help secure card.
Step 3 Install the ARI in the corresponding back slot. Use the extractor handles to help secure the card then tighten the captive screws by hand.
Step 4 Note that the FAIL LED on the ARM is off. The ACTIVE LED is also off.
Step 5 Attach a 22- or
See the section “Initial Startup of the IGX” on page 46, when the system is ready for power.
The steps that follow show how to set up an ARM card set after the physical installation is complete. This is done from the IGX control terminal or the Cisco WAN Manager workstation. For details on each command used, refer to the Cisco WAN Switching Command Reference.
Step 1 Verify that the node is equipped with the proper ARM front card and ARI back card by using the dspcds command. This will show in which slot they are located.
Card Installation and Node Startup