Cisco Systems N3KC3524P10G manual OL-25338-04

Page 53

Chapter 2 Installing the Cisco Nexus 3000 Series Switches

Grounding the Switch

Se n d d o c u m e n t c o m m e n t s t o n ex u s 3 k - d o c f e e d b a ck @ c i sc o . c o m

For preventing ESD damage, follow these guidelines:

Always use an ESD wrist strap and ensure that it makes maximum contact with bare skin.

ESD grounding straps are available with banana plugs, metal spring clips, or alligator clips. All chassis from the Cisco Nexus 3000 Series switches are equipped with a banana plug connector (identified by the ground symbol next to the connector) somewhere on the front panel. We recommend that you use a personal ESD grounding strap equipped with a banana plug.

If you choose to use the disposable ESD wrist strap supplied with most FRUs or an ESD wrist strap equipped with an alligator clip, you must attach the system ground lug to the chassis in order to provide a proper grounding point for the ESD wrist strap.

Note This system ground is also referred to as the network equipment building system (NEBS) ground.

If your chassis is not grounded by its connection to a grounded rack, you must connect the switch to an Earth ground. See the “Establishing the System Ground” section on page 2-12for installation instructions and the location of the chassis system ground pads.

Note You do not need to attach a supplemental system ground wire to the system ground lug; the lug provides a direct path to the bare metal of the chassis

After you install the system ground lug, follow.these steps to correctly attach the ESD wrist strap:

Step 1 Attach the ESD wrist strap to bare skin as follows:

a.If you are using the ESD wrist strap supplied with the field-replaceable units (FRUs), open the wrist strap package and unwrap the ESD wrist strap. Place the black conductive loop over your wrist and tighten the strap so that it makes good contact with your bare skin.

b.If you are using an ESD wrist strap equipped with an alligator clip, open the package and remove the ESD wrist strap. Locate the end of the wrist strap that attaches to your body and secure it to your bare skin.

Step 2 Grasp the spring or alligator clip on the ESD wrist strap and momentarily touch the clip to a bare metal spot (unpainted surface) on a grounded rack. We recommend that you touch the clip to an unpainted rack rail so that any built-up static charge is then safely dissipated to the entire rack.

Step 3 Attach either the spring clip or the alligator clip to an earth ground (grounded rack or the screw holding a grounding lug to the chassis):

a.If you are using the ESD wrist strap that is supplied with the FRUs, squeeze the spring clip jaws open, position the spring clip to one side of the system ground lug screw head, and slide the spring clip over the lug screw head so that the spring clip jaws close behind the lug screw head.

Note The spring clip jaws do not open wide enough to fit directly over the head of the lug screw or the lug barrel.

b.If you are using an ESD wrist strap that is equipped with an alligator clip, attach the alligator clip directly over the head of the system ground lug screw or to the system ground lug barrel.

 

 

Cisco Nexus 3000 Series Hardware Installation Guide

 

 

 

 

 

 

OL-25338-04

 

 

2-15

 

 

 

 

 

Image 53
Contents Americas Headquarters Cisco Nexus 3000 Series Hardware Installation GuidePage N T E N T S Airflow Direction Chassis Weight Chassis and Module Information E-4 Contents Chapter and Title Description AudienceOrganization Bewaar Deze Instructies ConventionsGuarde Estas Instruções Spara Dessa Anvisningar GEM Disse Anvisninger Xii Related Documentation Installation and Upgrade Guides Configuration GuidesCommand References Error and System MessagesObtaining Documentation and Submitting a Service Request Xvi Airflow Direction Layer 3 License Part Number Cisco Nexus 3016 SwitchFront View of the Cisco Nexus 3016 Switch Chassis for the Cisco Nexus 3016 SwitchID LED Ports for the Cisco Nexus 3016 SwitchAirflow Direction Power Supply Part Number Power Supply for the Cisco Nexus 3016 SwitchPart Number Transceivers and Cables Fan Tray for the Cisco Nexus 3016 SwitchPort Connections for the Cisco Nexus 3016 Switch Power Supply Airflow Direction Layer 3 License Part Number Cisco Nexus 3048 SwitchChassis for the Cisco Nexus 3048 Switch Front View of the Cisco Nexus 3048 Switch Rear View of the Cisco Nexus 3048 Switch Ports for the Cisco Nexus 3048 SwitchPower Supply for the Cisco Nexus 3048 Switch Port Connections for the Cisco Nexus 3048 Switch Fan Tray for the Cisco Nexus 3048 SwitchCisco Nexus 3064 Switch Front View of the Cisco Nexus 3064 Switch Chassis for the Cisco Nexus 3064 SwitchRear View of the Cisco Nexus 3064 Switch Ports for the Cisco Nexus 3064 SwitchFan Tray for the Cisco Nexus 3064 Switch Power Supply for the Cisco Nexus 3064 SwitchPort Connections for the Cisco Nexus 3064 Switch Chassis for the Cisco Nexus 3548 Switch Cisco Nexus 3548 SwitchPower Supplies Fan tray Rear View of the Cisco Nexus 3548 Switch Ports for the Cisco Nexus 3548 SwitchFan Tray for the Cisco Nexus 3548 Switch Power Supply for the Cisco Nexus 3548 SwitchPort Connections for the Cisco Nexus 3548 Switch SFP-10G-ER Cisco Nexus 3000 Series Hardware Installation Guide Statement Airflow Direction Preparing for InstallationInstallation Options with Racks and Cabinets Installation Guidelines Chassis WeightCisco Nexus 3000 Series Hardware Installation Guide Unpacking and Inspecting the Switch Installing the SwitchChassis Quantity Part DescriptionStep Installing the Slider Rails Sliding the Chassis Into the Rack Electrostatic Discharge Damage, page·2-14 Grounding the SwitchEnvironment Severity Level Grounding Recommendations Proper Grounding PracticesEstablishing the System Ground Grounding the Cisco Nexus 3000 Series Chassis Required Tools and EquipmentGrounding a Cisco Nexus 3000 Series Chassis Preventing Electrostatic Discharge DamageOL-25338-04 Attaching the ESD Wrist Strap to the System Ground Lug Screw Starting the Switch 331410 OL-25338-04 Cisco Nexus 3000 Series Hardware Installation Guide Connecting to the Network Preparing for Network Connections Connecting to the Console PortConnecting to a Server Connecting to the Management PortInstalling an SFP or SFP+ Transceiver Installing and Replacing SFP or SFP+ TransceiversReplacing an SFP or SFP+ Transceiver Installing Optical Cables into SFP or SFP+ TransceiversInstalling an Optical Cable into an SFP or SFP+ Transceiver Maintaining SFP and SFP+ Transceivers and Fiber-Optic Cables Cisco Nexus 3000 Series Hardware Installation Guide Removing an AC Power Supply Replacing a Power SupplyInstalling an AC Power Supply Removing a DC Power Supply Replacing a Fan Tray Installing a DC Power SupplyRemoving a Fan Tray Removing a Fan Tray, Installing a Fan Tray,Installing a Fan Tray General Requirements for Cabinets and Racks Cabinet and Rack RequirementsRequirements Specific to Standard Open Racks Requirements Specific to Perforated CabinetsCable Management Guidelines Cisco Nexus 3000 Series Hardware Installation Guide Switch Height Width Depth Weight Switch SpecificationsEnvironmental Specifications Property AC Power Supply N2200-PAC-400 W Power SpecificationsProperty Cisco Nexus 3000 Series Switch Property AC Power Supply N2200-PAC-400 W Appendix B Technical Specifications Power Specifications Console Cable Cable and Connector SpecificationsConsole Port Supported Power Cords and PlugsLength Description Feet Meters IllustrationCAB-N5K6A-NA CAB-9K10A-AU Figure C-6 SFS-250V-10A-ID CAB-9K10A-SW CAB-N5K6A-NA Figure C-15 Jumper Power CordLED Descriptions Status Description Chassis and Module LED DescriptionsComponent Port LEDs Power Supply StatusCondition Fail LED Status AmberRight Off No activity Blinking green Activity Site Preparation Checklist Site Planning and Maintenance RecordsTask No Planning Activity Verified By Time Date Contact and Site Information Chassis and Module Information D E IN-2 IN-3 IN-4 IN-5 IN-6