Cisco Systems SFS 7012 manual ShowChassisIpAddr, SetChassisIpAddr, NetMask

Page 118

Sample Output:

PING 172.26.0.254: 56 data bytes

64bytes from 172.26.0.254: icmp_seq=0. time=0. ms

64bytes from 172.26.0.254: icmp_seq=1. time=0. ms

64bytes from 172.26.0.254: icmp_seq=2. time=0. ms

64bytes from 172.26.0.254: icmp_seq=3. time=0. ms

64bytes from 172.26.0.254: icmp_seq=4. time=0. ms

----172.26.0.254 PING Statistics----

5packets transmitted, 5 packets received, 0% packet loss round-trip (ms) min/avg/max = 0/0/0

NOTES: This routine spawns a process to send ping packets to the specified IP address. If packetCount is given, the process exits after that number of packets are sent. If packetCount is ommitted, a default the number of packets defaults to 5. If packetCount is 0, the ping task will continue until the CLI is restarted (ctrl+c).

showChassisIpAddr

Displays the chassis IP address.

Syntax:

showChassisIpAddr

Options:

None.

Sample Output:

-> showChassisIpAddr

Chassis IP Address: 172.26.0.221 Net mask: 255.255.240.0

setChassisIpAddr

Change the module IP address.

Syntax:

setChassisIpAddr -h ipaddress -m netMask

Options:

-h ipaddress

The new IP address in dotted notation format 'xxx.xxx.xxx.xxx'.

-m netMask

The network mask. (may be in dotted notation or hexidecimal format)

Sample Output:

-> setChassisIpAddr -h 172.26.0.221 -m 255.255.240.0

Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide

 

B-26

OL-8787-05

 

 

 

Image 118
Contents Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Page Preface Logging Snmp Deprecated New and Changed Information Changed Feature Description Release Where Documented Preface Conventions Installation A P T E RStatement 1019-Main Disconnecting Device Statement 1045-Short-circuit Protection Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Page Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Planning the Installation Rack Specifications and RecommendationsCable Requirements Uninterruptible Power SupplyCable Distances Safety Information Installation Tasks ChecklistPrecautions for Rack-Mountable Products Electrical Safety Precautions Protecting Against Electrostatic DischargeCheck the Installation Site Tools, Equipment and Personnel RequiredInstallation Tasks Unpack the EquipmentMounting Kit Install the Rails in the RackMounting Hardware Kit Contents Mark the RackRack-Mount the Switch Secure Chassis to Rail Installing the Switch Face Plate Installing the Spine and Leaf Modules Removing a Module or BlankConnect Equipment to the Ports and Power On the System LeafLeaf Start-up Procedures Connecting PowerBringing Up the System For the First Time Changing the IP Address and Default Gateway 11 SFS 7012 RS-232 ConnectorUsing the RS232 Serial Port Using Telnet or SSHUsing the Chassis Viewer GUI Click in the Gateway address field Enter the new switch default gateway IP address Click Apply Information similar to the following NEW IP Address Subnet Manager Agent SMA LED SFS 7012 Component LEDsChassis Status LED RJ45 LEDsLeaf Module IB Port LEDs Power Supply LEDsSFS 7012 Leaf and Spine Module LEDs Spine and Leaf Module Status LEDHot Swapping Spine and Leaf Modules Shutdown ProceduresHot Swapping Components Spine Module Management LEDsHot Swapping Power Supplies Hot Swapping the Fan UnitTighten the captive panel screw Operations and Administration Chassis Viewer Manages HomeSupport Button Displaying the Leaf and Spine Module Views? Help Button Leaf Module ViewSpine Module View Leaf Module MouseoverLeaf and Spine Details Header Leaf and Spine Module Component Details AreaLeaf and Spine Information Area Apply Displaying the Chassis ViewRefresh Chassis View Component Details Area Rebooting Components from Chassis ViewerChassis Details Header Chassis View Component Information Area Chassis View Component Information Area TabsLEDs and Sensors Tab System TabPower Tab Chassis FRU TabBackplane Tab Modifying Switch Component InformationFan Tab StatusLogging Chassis View MenuSet Level 23 Log System Configurator Device Tab Preset Tab Syslog Tab Configure Syslog on a Linux ServerType /etc/init.d/syslog restart, and press Enter Reset Log Levels 27 Reset Levels ButtonMaintenance Firmware UpdateLdap Configuration 32 Ldap Configuration ButtonHTTP/CLI Session Configuration 34 HTTP/CLI Session Configuration ButtonTarget Configuration SnmpTarget Configuration Window Field Descriptions Snmp Target AddressesSnmp Target Parameters Filter Status Setting Community Strings 40 Filter Status ButtonConfiguration File Administration Administer46 Configuration File Administration Screen Host Upload/DownloadDownload saved configuration files from the CMU to a server Click Config File Admin Trap ControlChassis Group Chassis TrapsIcsChassisTrapSystemSelfTestFailure IcsChassisTrapModuleBulkPowerFailure IcsChassisTrapSystemRebootIcsChassisTrapSystemSwitchFailover IcsChassisTrapModuleRebootIcsChassisTrapPowerSupplyEEPROMReadFailure IcsChassisTrapPowerSupplyRemovedIcsChassisTrapPowerSupplyFailed IcsChassisTrapPowerSupplyFanFailedUnderstanding Port Naming Conventions Interswitch Link ISL PortsSFS 7012 Port Statistics Leaf modules/portsPort Statistics Field Descriptions InfiniBand Statistics Leaf Modules Leaf and Spine Module IB Port StatisticsSpine Modules Set Field Thresholds 59 Spine Port Stats MenuPortXmitPktsThresh PortXmitDataThreshPortRecvDataThresh PortRecvPktsThreshTime Service 63 Switch Time Service Click the Use Network Time Protocol? checkboxTime Zone Tips Daylight Saving Time TipsConfiguring the Switch Default Gateway IP Address Configuring the Switch OOB IP AddressFrom the OOB LAN IP submenu, click Set Default Gateway IP Type in the correct switch default gateway IP address Spine View Menu Viewing the LogSelect Edit, Copy or Ctrl + C Purging the LogSelect Edit, Paste or Ctrl + Select Boot Image 78 Purge Log Confirmation WindowAdding a New License Key License Keys Key AdministrationDeleting a License Key Click OK to delete Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Technical Specifications Table A-1 SFS 7012 Technical Specifications Administrator OperatorCommands and Functional Groups Keyboard Shortcuts Accessing the CLIOnline Help CaptureCommand Groups and CommandsHelp command GeneralGroup ListList group -noprompt -verbose NopromptReboot HistoryKillCliSession WhoMsg BroadcastBroadcast msg SwapBsDelGetTermWidth SetTermWidthPrompt ShowLastRetCode RloginRcmd Logout ResetCardUser Passwd UserAddUserListShow UserRemUserRem username UserListShowLoginMode SetldapSvrIpAddrIdleTimeoutSet IdleTimeoutGetSetldapSvrPort SessionTimeoutEnable SessionTimeoutDisableLoginMsgGet LoginNameGet LoginMsgSetLoginNameSet SerialAuthGet SerialAuthSetExit DeprecatedExit HwMonitor ChassisShowIBNodeDesc FruInfo SetIBNodeDescSetIBNodeDesc New Node String FruInfo slot-allType cardtype ChassisQueryShowType IgnoreInvalidTypeShowInventory ShowInventoryOptions NetworkIfShow Sample OutputPing RouteShowRouteShow Ping ipAddress packetCountSetChassisIpAddr ShowChassisIpAddrShowChassisIpAddr SetChassisIpAddr -h ipaddress -m netMaskSetDefaultRoute ShowDefaultRouteArpShow HostShow HostShowFwUpdateChassis FwUpdateSlotFirmware FwShowUpdateParams FwListFilesShowCapability FwSetUpdateParamsShowLastScpRetCode FwVersion BootQueryBootQuery slot -active -alternate -all FwVersion slotAlternate BootSelectActive IndexSubnetManagement SmConfigSmControl SmShowLids SmConfigSmShowLids Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide SmSetPriority SmShowPrioritySmSetSweepRate SmForceSweep BmSetSweepRateBmForceSweep SmShowGroups SmShowServicesSmShowServices SmShowGroups -hSmShowSubscriptions SmShowSubscriptionsSmShowMasterLMC SmShowMasterLMCSmShowMasterLid SmSetMasterLMCSmShowLidMap SmShowMaxLid SmSetSwitchLifetimeSmSetHoqLife SmSetVLStall SmShowSMParmsSmSetPKey SmShowPKeysSmShowKey SmSetKeySmSetMKey SmOptionConfig SmShowMKeySmSetDefBcGroup SmShowDefBcGroupSmShowGidPrefix SmSetGidPrefixSmSetSubnetSize SmShowSubnetSize LogSmShowSubnetSize LogShowLogClear LogConfigureLogConfigure LogClearLogResetToDefaults LogResetToDefaultsLogShowConfig LogSyslogConfigLogSyslogConfig -h xxx.xxx.xxx.xxx -p xxxx -f LogShowConfigShowKeys KeyManagementShowKeys AddKey IbSwitchInfoRemoveKey Leaf IsmPortStatsCols SpineIsmPortCounters Potential IsmPortCounters -clear -active -errors -potential -nopromptErrors IsmLinearFwdbIsmMultiFwdb switch IsmLinearFwdb switchSwitch IsmMultiFwdbIsmPortSet12x IsmChassisSet12x enable12xBit IsmChassisSet12xIsmChassisSetSpeed IsmPortEnableIsmPortEnable port IsmChassisSetSpeed speedIsmPortDisable IsmChassisSetEnableIsmChassisSetEnable enable IsmPortDisable portIsmPortSetSpeed port speed IsmIslSet12x enable12xBitIsmPortSetSpeed IsmIslSet12xIsmIslSetSpeed IsmChassisSetMtuIsmChassisSetMtu mtu IsmIslSetSpeed speedFlagIsmShowPStatThresh IsmShowPStatThreshField IsmSetPStatThreshIsmSetPStatThresh field threshold ThresholdCisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Time TimeManagementTimeZoneConf TimeDSTConf TimeNtpTimeoutTimeNtpTimeout numSeconds TimeDSTConf sw sd sm ew ed emTimeNtpRefreshTime NumSecondsTimeNtpRefreshTime numSeconds SnmpCommunityConf -r readonlycommstr -w readwritecommstr SnmpCommunityConfSnmpTargetAddr Edit ShowAdd DeleteSnmpNotifyProfile SnmpTargetParamsDisplays the snmpTargetParamsTable entries Displays the snmpNotifyFilterProfileTable entriesSnmpNotifyFilter show SnmpNotifyFilterDisplays the snmpNotifyFilterTable entries SnmpNotifySnmpUsrSec SnmpSystemSnmpUsrSec add show edit delete name -a algo key Capture CaptureCapture CaptureSm CaptureFwCaptureLog CaptureIsmCaptureNetwork CaptureChassisCaptureMisc CaptureShell CaptureSnmpCaptureSnmp CaptureShellPower Supply SwitchProblem Fix SFS 7012 Leaf Module IB Ports Problem Fix OOB Ethernet RJ45 PortInfiniBand SymptomsResolution / Workaround Invalid IP Address entered via Console PortCisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
Related manuals