Cisco Systems SFS 7012 manual SmSetVLStall, SmShowSMParms

Page 136

Options:

hoq-lifetime

Sample Output:

-> smSetHoqLife 11

The SM Head of Queue Lifetime has been set to 11

NOTES: Use this command to set the head of queue lifetime in the subnet manager.

smSetVLStall

Set the VL stall value in the subnet manager.

Syntax:

smSetVLStall [vl-stall]

Options:

vl-stall

Sample Output:

-> smSetVLStall 7

The SM VL Stall value has been set to 7

NOTES: Use this command to set the VL stall value in the subnet manager.

smShowSMParms

Display subnet manager parameters switch lifetime, HOQ lifetime, VLStall val, pkt lifetime, and dynamic PLT.

Syntax:

smShowSMParms

Options:

None.

Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide

 

B-44

OL-8787-05

 

 

 

Image 136
Contents Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Page Preface Logging Snmp Deprecated New and Changed Information Changed Feature Description Release Where Documented Preface Conventions Installation A P T E RStatement 1019-Main Disconnecting Device Statement 1045-Short-circuit Protection Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Page Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Planning the Installation Rack Specifications and RecommendationsCable Requirements Uninterruptible Power SupplyCable Distances Safety Information Installation Tasks ChecklistPrecautions for Rack-Mountable Products Electrical Safety Precautions Protecting Against Electrostatic DischargeCheck the Installation Site Tools, Equipment and Personnel RequiredInstallation Tasks Unpack the EquipmentInstall the Rails in the Rack Mounting Hardware Kit ContentsMounting Kit Mark the RackRack-Mount the Switch Secure Chassis to Rail Installing the Switch Face Plate Installing the Spine and Leaf Modules Removing a Module or BlankConnect Equipment to the Ports and Power On the System LeafLeaf Start-up Procedures Connecting PowerBringing Up the System For the First Time Changing the IP Address and Default Gateway 11 SFS 7012 RS-232 ConnectorUsing the RS232 Serial Port Using Telnet or SSHUsing the Chassis Viewer GUI Click in the Gateway address field Enter the new switch default gateway IP address Click Apply Information similar to the following NEW IP Address SFS 7012 Component LEDs Chassis Status LEDSubnet Manager Agent SMA LED RJ45 LEDsPower Supply LEDs SFS 7012 Leaf and Spine Module LEDsLeaf Module IB Port LEDs Spine and Leaf Module Status LEDShutdown Procedures Hot Swapping ComponentsHot Swapping Spine and Leaf Modules Spine Module Management LEDsHot Swapping Power Supplies Hot Swapping the Fan UnitTighten the captive panel screw Operations and Administration Chassis Viewer Manages HomeDisplaying the Leaf and Spine Module Views ? Help ButtonSupport Button Leaf Module ViewSpine Module View Leaf Module MouseoverLeaf and Spine Details Header Leaf and Spine Module Component Details AreaLeaf and Spine Information Area Apply Displaying the Chassis ViewRefresh Chassis View Component Details Area Rebooting Components from Chassis ViewerChassis Details Header Chassis View Component Information Area Chassis View Component Information Area TabsLEDs and Sensors Tab System TabPower Tab Chassis FRU TabModifying Switch Component Information Fan TabBackplane Tab StatusLogging Chassis View MenuSet Level 23 Log System Configurator Device Tab Preset Tab Syslog Tab Configure Syslog on a Linux ServerType /etc/init.d/syslog restart, and press Enter Reset Log Levels 27 Reset Levels ButtonMaintenance Firmware UpdateLdap Configuration 32 Ldap Configuration ButtonHTTP/CLI Session Configuration 34 HTTP/CLI Session Configuration ButtonTarget Configuration SnmpTarget Configuration Window Field Descriptions Snmp Target AddressesSnmp Target Parameters Filter Status Setting Community Strings 40 Filter Status ButtonConfiguration File Administration Administer46 Configuration File Administration Screen Host Upload/DownloadDownload saved configuration files from the CMU to a server Click Config File Admin Trap ControlChassis Group Chassis TrapsIcsChassisTrapSystemSelfTestFailure IcsChassisTrapSystemReboot IcsChassisTrapSystemSwitchFailoverIcsChassisTrapModuleBulkPowerFailure IcsChassisTrapModuleRebootIcsChassisTrapPowerSupplyRemoved IcsChassisTrapPowerSupplyFailedIcsChassisTrapPowerSupplyEEPROMReadFailure IcsChassisTrapPowerSupplyFanFailedInterswitch Link ISL Ports SFS 7012 Port StatisticsUnderstanding Port Naming Conventions Leaf modules/portsPort Statistics Field Descriptions InfiniBand Statistics Leaf Modules Leaf and Spine Module IB Port StatisticsSpine Modules Set Field Thresholds 59 Spine Port Stats MenuPortXmitDataThresh PortRecvDataThreshPortXmitPktsThresh PortRecvPktsThreshTime Service 63 Switch Time Service Click the Use Network Time Protocol? checkboxTime Zone Tips Daylight Saving Time TipsConfiguring the Switch Default Gateway IP Address Configuring the Switch OOB IP AddressFrom the OOB LAN IP submenu, click Set Default Gateway IP Type in the correct switch default gateway IP address Spine View Menu Viewing the LogSelect Edit, Copy or Ctrl + C Purging the LogSelect Edit, Paste or Ctrl + Select Boot Image 78 Purge Log Confirmation WindowAdding a New License Key License Keys Key AdministrationDeleting a License Key Click OK to delete Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Technical Specifications Table A-1 SFS 7012 Technical Specifications Administrator OperatorCommands and Functional Groups Accessing the CLI Online HelpKeyboard Shortcuts CaptureGroups and Commands Help commandCommand GeneralList List group -noprompt -verboseGroup NopromptReboot HistoryKillCliSession WhoBroadcast Broadcast msgMsg SwapBsDelGetTermWidth SetTermWidthPrompt ShowLastRetCode RloginRcmd Logout ResetCardUser Passwd UserAddUserRem UserRem usernameUserListShow UserListShowLoginMode SetldapSvrIpAddrIdleTimeoutSet IdleTimeoutGetSetldapSvrPort SessionTimeoutEnable SessionTimeoutDisableLoginMsgGet LoginNameGet LoginMsgSetLoginNameSet SerialAuthGet SerialAuthSetExit DeprecatedExit HwMonitor ChassisShowIBNodeDesc SetIBNodeDesc SetIBNodeDesc New Node StringFruInfo FruInfo slot-allChassisQuery ShowTypeType cardtype IgnoreInvalidTypeShowInventory ShowInventoryNetwork IfShowOptions Sample OutputRouteShow RouteShowPing Ping ipAddress packetCountShowChassisIpAddr ShowChassisIpAddrSetChassisIpAddr SetChassisIpAddr -h ipaddress -m netMaskSetDefaultRoute ShowDefaultRouteArpShow HostShow HostShowFwUpdateChassis FwUpdateSlotFirmware FwShowUpdateParams FwListFilesShowCapability FwSetUpdateParamsShowLastScpRetCode BootQuery BootQuery slot -active -alternate -allFwVersion FwVersion slotBootSelect ActiveAlternate IndexSubnetManagement SmConfigSmControl SmShowLids SmConfigSmShowLids Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide SmSetPriority SmShowPrioritySmSetSweepRate SmForceSweep BmSetSweepRateBmForceSweep SmShowServices SmShowServicesSmShowGroups SmShowGroups -hSmShowSubscriptions SmShowSubscriptionsSmShowMasterLMC SmShowMasterLMCSmShowMasterLid SmSetMasterLMCSmShowLidMap SmShowMaxLid SmSetSwitchLifetimeSmSetHoqLife SmSetVLStall SmShowSMParmsSmSetPKey SmShowPKeysSmShowKey SmSetKeySmSetMKey SmOptionConfig SmShowMKeySmSetDefBcGroup SmShowDefBcGroupSmShowGidPrefix SmSetGidPrefixSmSetSubnetSize Log SmShowSubnetSizeSmShowSubnetSize LogShowLogConfigure LogConfigureLogClear LogClearLogResetToDefaults LogResetToDefaultsLogSyslogConfig LogSyslogConfig -h xxx.xxx.xxx.xxx -p xxxx -fLogShowConfig LogShowConfigShowKeys KeyManagementShowKeys AddKey IbSwitchInfoRemoveKey IsmPortStats ColsLeaf SpineIsmPortCounters IsmPortCounters -clear -active -errors -potential -noprompt ErrorsPotential IsmLinearFwdbIsmLinearFwdb switch SwitchIsmMultiFwdb switch IsmMultiFwdbIsmPortSet12x IsmChassisSet12x enable12xBit IsmChassisSet12xIsmPortEnable IsmPortEnable portIsmChassisSetSpeed IsmChassisSetSpeed speedIsmChassisSetEnable IsmChassisSetEnable enableIsmPortDisable IsmPortDisable portIsmIslSet12x enable12xBit IsmPortSetSpeedIsmPortSetSpeed port speed IsmIslSet12xIsmChassisSetMtu IsmChassisSetMtu mtuIsmIslSetSpeed IsmIslSetSpeed speedFlagIsmShowPStatThresh IsmShowPStatThreshIsmSetPStatThresh IsmSetPStatThresh field thresholdField ThresholdCisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Time TimeManagementTimeZoneConf TimeNtpTimeout TimeNtpTimeout numSecondsTimeDSTConf TimeDSTConf sw sd sm ew ed emTimeNtpRefreshTime NumSecondsTimeNtpRefreshTime numSeconds SnmpCommunityConf -r readonlycommstr -w readwritecommstr SnmpCommunityConfSnmpTargetAddr Show AddEdit DeleteSnmpTargetParams Displays the snmpTargetParamsTable entriesSnmpNotifyProfile Displays the snmpNotifyFilterProfileTable entriesSnmpNotifyFilter Displays the snmpNotifyFilterTable entriesSnmpNotifyFilter show SnmpNotifySnmpUsrSec SnmpSystemSnmpUsrSec add show edit delete name -a algo key Capture CaptureCapture CaptureFw CaptureLogCaptureSm CaptureIsmCaptureNetwork CaptureChassisCaptureMisc CaptureSnmp CaptureSnmpCaptureShell CaptureShellPower Supply SwitchProblem Fix SFS 7012 Leaf Module IB Ports Problem Fix OOB Ethernet RJ45 PortSymptoms Resolution / WorkaroundInfiniBand Invalid IP Address entered via Console PortCisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
Related manuals
Manual 116 pages 14.21 Kb