Cisco Systems SFS 7012 manual NEW IP Address

Page 37

CPU0 flushing caches L2 flush complete Start type = 0xBFC006A0 Jumping to romStart Initializing HyperTransport bus HyperTransport initialization completed

rintf MBOX connect interrupt_source=28 vector=62 status=0 Printf MBOX intEnable status=0

Found Intel Strata Flash 128 MBit (0x8918).

Mounted raw file system on device /image1. (size=6291456 bytes) Mounted raw file system on device /image2. (size=6291456 bytes) Mounted raw file system on device /dump0. (size=1048576 bytes)

Mounted flash file system on device /rfa1. (size=2097152 bytes)

Unified Boot Manager

[1]image1

[2]image2

CPU: Broadcom BCM1125

VxWorks Version: 5.4

boot device

:

icspkg0

processor number

:

0

host name

: home

file name

: /image1

inet on ethernet (e)

: <NEW IP ADDRESS>

inet on backplane (b):

 

host inet (h)

: 192.168.100.1

gateway inet (g)

:

 

user (u)

: ftp

ftp password (pw) (blank = use rsh): ftp

flags (f)

: 0x0

target name (tn)

:

 

startup script (s)

:

 

other (o)

: sbe

Loading package from

flash device /image1 ...

Boot System

 

= 7012

Boot Image Information:

 

Product

 

= SFS7012

BSP

 

= t3

Version

 

= 4.1.1.1.11

Compressed Image Size = 3616523 bytes

md5

 

= 46086777be1b5bae45140a440425b915

vxWorks Image Type

 

= loadable

Computed md5

 

= 46086777be1b5bae45140a440425b915

md5 values match! 11088736

Starting at 0x80010000...

sysI

REGS

BOOT

Initializing HyperTransport bus HyperTransport initialization completed Found Intel Strata Flash 128 MBit (0x8918).

Mounted raw file system on device /image1. (size=6291456 bytes) Mounted raw file system on device /image2. (size=6291456 bytes) Mounted raw file system on device /dump0. (size=1048576 bytes)

Mounted flash file system on device /rfa1. (size=2097152 bytes) Network configuration requested.

cliEnabled=1

sbe0 speed=100 fullDuplex=0 flowControl=0

Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide

 

OL-8787-05

1-27

 

 

 

Image 37
Contents Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Page Preface Logging Snmp Deprecated New and Changed Information Changed Feature Description Release Where Documented Preface Conventions A P T E R InstallationStatement 1019-Main Disconnecting Device Statement 1045-Short-circuit Protection Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Page Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Rack Specifications and Recommendations Planning the InstallationCable Requirements Uninterruptible Power SupplyCable Distances Safety Information Installation Tasks ChecklistPrecautions for Rack-Mountable Products Protecting Against Electrostatic Discharge Electrical Safety PrecautionsTools, Equipment and Personnel Required Check the Installation SiteUnpack the Equipment Installation TasksMounting Hardware Kit Contents Install the Rails in the RackMounting Kit Mark the RackRack-Mount the Switch Secure Chassis to Rail Installing the Switch Face Plate Removing a Module or Blank Installing the Spine and Leaf ModulesLeaf Connect Equipment to the Ports and Power On the SystemLeaf Start-up Procedures Connecting PowerBringing Up the System For the First Time 11 SFS 7012 RS-232 Connector Changing the IP Address and Default GatewayUsing Telnet or SSH Using the RS232 Serial PortUsing the Chassis Viewer GUI Click in the Gateway address field Enter the new switch default gateway IP address Click Apply Information similar to the following NEW IP Address Chassis Status LED SFS 7012 Component LEDsSubnet Manager Agent SMA LED RJ45 LEDsSFS 7012 Leaf and Spine Module LEDs Power Supply LEDsLeaf Module IB Port LEDs Spine and Leaf Module Status LEDHot Swapping Components Shutdown ProceduresHot Swapping Spine and Leaf Modules Spine Module Management LEDsHot Swapping the Fan Unit Hot Swapping Power SuppliesTighten the captive panel screw Operations and Administration Home Chassis Viewer Manages? Help Button Displaying the Leaf and Spine Module ViewsSupport Button Leaf Module ViewLeaf Module Mouseover Spine Module ViewLeaf and Spine Details Header Leaf and Spine Module Component Details AreaLeaf and Spine Information Area Apply Displaying the Chassis ViewRefresh Chassis View Component Details Area Rebooting Components from Chassis ViewerChassis Details Header Chassis View Component Information Area Tabs Chassis View Component Information AreaSystem Tab LEDs and Sensors TabChassis FRU Tab Power TabFan Tab Modifying Switch Component InformationBackplane Tab StatusLogging Chassis View MenuSet Level 23 Log System Configurator Device Tab Preset Tab Syslog Tab Configure Syslog on a Linux ServerType /etc/init.d/syslog restart, and press Enter 27 Reset Levels Button Reset Log LevelsFirmware Update Maintenance32 Ldap Configuration Button Ldap Configuration34 HTTP/CLI Session Configuration Button HTTP/CLI Session ConfigurationSnmp Target ConfigurationSnmp Target Addresses Target Configuration Window Field DescriptionsSnmp Target Parameters Filter Status 40 Filter Status Button Setting Community StringsAdminister Configuration File AdministrationHost Upload/Download 46 Configuration File Administration ScreenDownload saved configuration files from the CMU to a server Trap Control Click Config File AdminChassis Group Chassis TrapsIcsChassisTrapSystemSelfTestFailure IcsChassisTrapSystemSwitchFailover IcsChassisTrapSystemRebootIcsChassisTrapModuleBulkPowerFailure IcsChassisTrapModuleRebootIcsChassisTrapPowerSupplyFailed IcsChassisTrapPowerSupplyRemovedIcsChassisTrapPowerSupplyEEPROMReadFailure IcsChassisTrapPowerSupplyFanFailedSFS 7012 Port Statistics Interswitch Link ISL PortsUnderstanding Port Naming Conventions Leaf modules/portsPort Statistics Field Descriptions InfiniBand Statistics Leaf Modules Leaf and Spine Module IB Port StatisticsSpine Modules 59 Spine Port Stats Menu Set Field ThresholdsPortRecvDataThresh PortXmitDataThreshPortXmitPktsThresh PortRecvPktsThreshTime Service Click the Use Network Time Protocol? checkbox 63 Switch Time ServiceDaylight Saving Time Tips Time Zone TipsConfiguring the Switch Default Gateway IP Address Configuring the Switch OOB IP AddressFrom the OOB LAN IP submenu, click Set Default Gateway IP Type in the correct switch default gateway IP address Viewing the Log Spine View MenuSelect Edit, Copy or Ctrl + C Purging the LogSelect Edit, Paste or Ctrl + 78 Purge Log Confirmation Window Select Boot ImageAdding a New License Key License Keys Key AdministrationDeleting a License Key Click OK to delete Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Technical Specifications Table A-1 SFS 7012 Technical Specifications Operator AdministratorCommands and Functional Groups Online Help Accessing the CLIKeyboard Shortcuts CaptureHelp command Groups and CommandsCommand GeneralList group -noprompt -verbose ListGroup NopromptHistory RebootWho KillCliSessionBroadcast msg BroadcastMsg SwapBsDelGetTermWidth SetTermWidthPrompt ShowLastRetCode RloginRcmd Logout ResetCardUser UserAdd PasswdUserRem username UserRemUserListShow UserListShowSetldapSvrIpAddr LoginModeIdleTimeoutSet IdleTimeoutGetSetldapSvrPort SessionTimeoutEnable SessionTimeoutDisableLoginMsgGet LoginNameGet LoginMsgSetLoginNameSet SerialAuthSet SerialAuthGetExit DeprecatedExit HwMonitor ChassisShowIBNodeDesc SetIBNodeDesc New Node String SetIBNodeDescFruInfo FruInfo slot-allShowType ChassisQueryType cardtype IgnoreInvalidTypeShowInventory ShowInventoryIfShow NetworkOptions Sample OutputRouteShow RouteShowPing Ping ipAddress packetCountShowChassisIpAddr ShowChassisIpAddrSetChassisIpAddr SetChassisIpAddr -h ipaddress -m netMaskSetDefaultRoute ShowDefaultRouteArpShow HostShow HostShowFwUpdateChassis FwUpdateSlotFirmware FwListFiles FwShowUpdateParamsShowCapability FwSetUpdateParamsShowLastScpRetCode BootQuery slot -active -alternate -all BootQueryFwVersion FwVersion slotActive BootSelectAlternate IndexSubnetManagement SmConfigSmControl SmShowLids SmConfigSmShowLids Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide SmSetPriority SmShowPrioritySmSetSweepRate SmForceSweep BmSetSweepRateBmForceSweep SmShowServices SmShowServicesSmShowGroups SmShowGroups -hSmShowSubscriptions SmShowSubscriptionsSmShowMasterLMC SmShowMasterLMCSmShowMasterLid SmSetMasterLMCSmShowLidMap SmShowMaxLid SmSetSwitchLifetimeSmSetHoqLife SmShowSMParms SmSetVLStallSmShowPKeys SmSetPKeySmShowKey SmSetKeySmSetMKey SmShowMKey SmOptionConfigSmShowDefBcGroup SmSetDefBcGroupSmShowGidPrefix SmSetGidPrefixSmSetSubnetSize SmShowSubnetSize LogSmShowSubnetSize LogShowLogConfigure LogConfigureLogClear LogClearLogResetToDefaults LogResetToDefaultsLogSyslogConfig -h xxx.xxx.xxx.xxx -p xxxx -f LogSyslogConfigLogShowConfig LogShowConfigShowKeys KeyManagementShowKeys AddKey IbSwitchInfoRemoveKey Cols IsmPortStatsLeaf SpineIsmPortCounters Errors IsmPortCounters -clear -active -errors -potential -nopromptPotential IsmLinearFwdbSwitch IsmLinearFwdb switchIsmMultiFwdb switch IsmMultiFwdbIsmPortSet12x IsmChassisSet12x IsmChassisSet12x enable12xBitIsmPortEnable port IsmPortEnableIsmChassisSetSpeed IsmChassisSetSpeed speedIsmChassisSetEnable enable IsmChassisSetEnableIsmPortDisable IsmPortDisable portIsmPortSetSpeed IsmIslSet12x enable12xBitIsmPortSetSpeed port speed IsmIslSet12xIsmChassisSetMtu mtu IsmChassisSetMtuIsmIslSetSpeed IsmIslSetSpeed speedFlagIsmShowPStatThresh IsmShowPStatThreshIsmSetPStatThresh field threshold IsmSetPStatThreshField ThresholdCisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Time TimeManagementTimeZoneConf TimeNtpTimeout numSeconds TimeNtpTimeoutTimeDSTConf TimeDSTConf sw sd sm ew ed emTimeNtpRefreshTime NumSecondsTimeNtpRefreshTime numSeconds SnmpCommunityConf -r readonlycommstr -w readwritecommstr SnmpCommunityConfSnmpTargetAddr Add ShowEdit DeleteDisplays the snmpTargetParamsTable entries SnmpTargetParamsSnmpNotifyProfile Displays the snmpNotifyFilterProfileTable entriesDisplays the snmpNotifyFilterTable entries SnmpNotifyFilterSnmpNotifyFilter show SnmpNotifySnmpUsrSec SnmpSystemSnmpUsrSec add show edit delete name -a algo key Capture CaptureCapture CaptureLog CaptureFwCaptureSm CaptureIsmCaptureNetwork CaptureChassisCaptureMisc CaptureSnmp CaptureSnmpCaptureShell CaptureShellPower Supply SwitchProblem Fix OOB Ethernet RJ45 Port SFS 7012 Leaf Module IB Ports Problem FixResolution / Workaround SymptomsInfiniBand Invalid IP Address entered via Console PortCisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
Related manuals
Manual 116 pages 14.21 Kb