Cisco Systems SFS 7012 manual Active, Alternate, BootSelect, Index, Version version

Page 125

Options:

-slot

Slot number.

-active

Displays the version of the active firmware image.

-alternate

Displays the version of the alternate firmware image.

-all

Displays the versions for the primary and alternate firmware images.

Sample Output:

-> bootQuery 105 -all

Primary firmware version: 4.1.1.1.11

Alternate firmware version: 3.4.0.11.3

Active firmware version: 4.1.1.1.11

bootSelect

Select the next boot image to be used.

Syntax:

bootSelect slot [-i index] [-alternate] [-version version] [-noprompt]

Options:

slot

The slot number using the next boot image.

-i index

The index of the boot image to be used next.

-alternate

Chooses the alternate image to be used next.

-version version

Chooses a specific version to be the image to be used next.

-noprompt

Displays the current configuration only.

Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide

 

OL-8787-05

B-33

 

Image 125
Contents Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Page Preface Logging Snmp Deprecated New and Changed Information Changed Feature Description Release Where Documented Preface Conventions A P T E R InstallationStatement 1019-Main Disconnecting Device Statement 1045-Short-circuit Protection Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Page Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Rack Specifications and Recommendations Planning the InstallationCable Distances Uninterruptible Power SupplyCable Requirements Precautions for Rack-Mountable Products Installation Tasks ChecklistSafety Information Protecting Against Electrostatic Discharge Electrical Safety PrecautionsTools, Equipment and Personnel Required Check the Installation SiteUnpack the Equipment Installation TasksMounting Hardware Kit Contents Install the Rails in the RackMounting Kit Mark the RackRack-Mount the Switch Secure Chassis to Rail Installing the Switch Face Plate Removing a Module or Blank Installing the Spine and Leaf ModulesLeaf Connect Equipment to the Ports and Power On the SystemLeaf Bringing Up the System For the First Time Connecting PowerStart-up Procedures 11 SFS 7012 RS-232 Connector Changing the IP Address and Default GatewayUsing Telnet or SSH Using the RS232 Serial PortUsing the Chassis Viewer GUI Click in the Gateway address field Enter the new switch default gateway IP address Click Apply Information similar to the following NEW IP Address Chassis Status LED SFS 7012 Component LEDsSubnet Manager Agent SMA LED RJ45 LEDsSFS 7012 Leaf and Spine Module LEDs Power Supply LEDsLeaf Module IB Port LEDs Spine and Leaf Module Status LEDHot Swapping Components Shutdown ProceduresHot Swapping Spine and Leaf Modules Spine Module Management LEDsHot Swapping the Fan Unit Hot Swapping Power SuppliesTighten the captive panel screw Operations and Administration Home Chassis Viewer Manages? Help Button Displaying the Leaf and Spine Module ViewsSupport Button Leaf Module ViewLeaf Module Mouseover Spine Module ViewLeaf and Spine Information Area Leaf and Spine Module Component Details AreaLeaf and Spine Details Header Refresh Displaying the Chassis ViewApply Chassis Details Header Rebooting Components from Chassis ViewerChassis View Component Details Area Chassis View Component Information Area Tabs Chassis View Component Information AreaSystem Tab LEDs and Sensors TabChassis FRU Tab Power TabFan Tab Modifying Switch Component InformationBackplane Tab StatusSet Level Chassis View MenuLogging 23 Log System Configurator Device Tab Preset Tab Type /etc/init.d/syslog restart, and press Enter Configure Syslog on a Linux ServerSyslog Tab 27 Reset Levels Button Reset Log LevelsFirmware Update Maintenance32 Ldap Configuration Button Ldap Configuration34 HTTP/CLI Session Configuration Button HTTP/CLI Session ConfigurationSnmp Target ConfigurationSnmp Target Addresses Target Configuration Window Field DescriptionsSnmp Target Parameters Filter Status 40 Filter Status Button Setting Community StringsAdminister Configuration File AdministrationHost Upload/Download 46 Configuration File Administration ScreenDownload saved configuration files from the CMU to a server Trap Control Click Config File AdminIcsChassisTrapSystemSelfTestFailure Chassis TrapsChassis Group IcsChassisTrapSystemSwitchFailover IcsChassisTrapSystemRebootIcsChassisTrapModuleBulkPowerFailure IcsChassisTrapModuleRebootIcsChassisTrapPowerSupplyFailed IcsChassisTrapPowerSupplyRemovedIcsChassisTrapPowerSupplyEEPROMReadFailure IcsChassisTrapPowerSupplyFanFailedSFS 7012 Port Statistics Interswitch Link ISL PortsUnderstanding Port Naming Conventions Leaf modules/portsPort Statistics Field Descriptions InfiniBand Statistics Spine Modules Leaf and Spine Module IB Port StatisticsLeaf Modules 59 Spine Port Stats Menu Set Field ThresholdsPortRecvDataThresh PortXmitDataThreshPortXmitPktsThresh PortRecvPktsThreshTime Service Click the Use Network Time Protocol? checkbox 63 Switch Time ServiceDaylight Saving Time Tips Time Zone TipsFrom the OOB LAN IP submenu, click Set Default Gateway IP Configuring the Switch OOB IP AddressConfiguring the Switch Default Gateway IP Address Type in the correct switch default gateway IP address Viewing the Log Spine View MenuSelect Edit, Paste or Ctrl + Purging the LogSelect Edit, Copy or Ctrl + C 78 Purge Log Confirmation Window Select Boot ImageDeleting a License Key License Keys Key AdministrationAdding a New License Key Click OK to delete Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Technical Specifications Table A-1 SFS 7012 Technical Specifications Operator AdministratorCommands and Functional Groups Online Help Accessing the CLIKeyboard Shortcuts CaptureHelp command Groups and CommandsCommand GeneralList group -noprompt -verbose ListGroup NopromptHistory RebootWho KillCliSessionBroadcast msg BroadcastMsg SwapBsDelPrompt SetTermWidthGetTermWidth Rcmd RloginShowLastRetCode User ResetCardLogout UserAdd PasswdUserRem username UserRemUserListShow UserListShowSetldapSvrIpAddr LoginModeSetldapSvrPort IdleTimeoutGetIdleTimeoutSet LoginMsgGet SessionTimeoutDisableSessionTimeoutEnable LoginNameSet LoginMsgSetLoginNameGet SerialAuthSet SerialAuthGetExit DeprecatedExit ShowIBNodeDesc ChassisHwMonitor SetIBNodeDesc New Node String SetIBNodeDescFruInfo FruInfo slot-allShowType ChassisQueryType cardtype IgnoreInvalidTypeShowInventory ShowInventoryIfShow NetworkOptions Sample OutputRouteShow RouteShowPing Ping ipAddress packetCountShowChassisIpAddr ShowChassisIpAddrSetChassisIpAddr SetChassisIpAddr -h ipaddress -m netMaskArpShow ShowDefaultRouteSetDefaultRoute HostShow HostShowFirmware FwUpdateSlotFwUpdateChassis FwListFiles FwShowUpdateParamsShowLastScpRetCode FwSetUpdateParamsShowCapability BootQuery slot -active -alternate -all BootQueryFwVersion FwVersion slotActive BootSelectAlternate IndexSmControl SmConfigSubnetManagement SmShowLids SmConfigSmShowLids Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide SmSetSweepRate SmShowPrioritySmSetPriority BmForceSweep BmSetSweepRateSmForceSweep SmShowServices SmShowServicesSmShowGroups SmShowGroups -hSmShowSubscriptions SmShowSubscriptionsSmShowMasterLMC SmShowMasterLMCSmShowLidMap SmSetMasterLMCSmShowMasterLid SmSetHoqLife SmSetSwitchLifetimeSmShowMaxLid SmShowSMParms SmSetVLStallSmShowPKeys SmSetPKeySmSetMKey SmSetKeySmShowKey SmShowMKey SmOptionConfigSmShowDefBcGroup SmSetDefBcGroupSmSetSubnetSize SmSetGidPrefixSmShowGidPrefix SmShowSubnetSize LogSmShowSubnetSize LogShowLogConfigure LogConfigureLogClear LogClearLogResetToDefaults LogResetToDefaultsLogSyslogConfig -h xxx.xxx.xxx.xxx -p xxxx -f LogSyslogConfigLogShowConfig LogShowConfigShowKeys KeyManagementShowKeys RemoveKey IbSwitchInfoAddKey Cols IsmPortStatsLeaf SpineIsmPortCounters Errors IsmPortCounters -clear -active -errors -potential -nopromptPotential IsmLinearFwdbSwitch IsmLinearFwdb switchIsmMultiFwdb switch IsmMultiFwdbIsmPortSet12x IsmChassisSet12x IsmChassisSet12x enable12xBitIsmPortEnable port IsmPortEnableIsmChassisSetSpeed IsmChassisSetSpeed speedIsmChassisSetEnable enable IsmChassisSetEnableIsmPortDisable IsmPortDisable portIsmPortSetSpeed IsmIslSet12x enable12xBitIsmPortSetSpeed port speed IsmIslSet12xIsmChassisSetMtu mtu IsmChassisSetMtuIsmIslSetSpeed IsmIslSetSpeed speedFlagIsmShowPStatThresh IsmShowPStatThreshIsmSetPStatThresh field threshold IsmSetPStatThreshField ThresholdCisco SFS 7012 InfiniBand Server Switch Hardware Users Guide TimeZoneConf TimeManagementTime TimeNtpTimeout numSeconds TimeNtpTimeoutTimeDSTConf TimeDSTConf sw sd sm ew ed emTimeNtpRefreshTime numSeconds NumSecondsTimeNtpRefreshTime SnmpTargetAddr SnmpCommunityConfSnmpCommunityConf -r readonlycommstr -w readwritecommstr Add ShowEdit DeleteDisplays the snmpTargetParamsTable entries SnmpTargetParamsSnmpNotifyProfile Displays the snmpNotifyFilterProfileTable entriesDisplays the snmpNotifyFilterTable entries SnmpNotifyFilterSnmpNotifyFilter show SnmpNotifySnmpUsrSec add show edit delete name -a algo key SnmpSystemSnmpUsrSec Capture CaptureCapture CaptureLog CaptureFwCaptureSm CaptureIsmCaptureMisc CaptureChassisCaptureNetwork CaptureSnmp CaptureSnmpCaptureShell CaptureShellProblem Fix SwitchPower Supply OOB Ethernet RJ45 Port SFS 7012 Leaf Module IB Ports Problem FixResolution / Workaround SymptomsInfiniBand Invalid IP Address entered via Console PortCisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
Related manuals