Cisco Systems SFS 7012 manual IsmPortSetSpeed port speed, IsmIslSet12x enable12xBit

Page 156

Note The option port is case sensitive. If it contains spaces, it must be bounded by quotes (e.g., ismPortEnable "Cable 1"). A reboot is required to activate changes made with this command. This reboot will be disruptive and will cause the affected switch chips to be reset and have a part of their EEPROM to be reloaded.

ismPortSetSpeed

Allows the user to view and set port speeds.

Syntax:

ismPortSetSpeed port [speed]

Options:

-port

Port name.

-speed

The port speed (1=SDR, 2=DDR, 3=AutoNegotiate).

Sample Output:

-> ismPortSetSpeed S3BL08b

S3BL08b link speed is AUTO NEGOTIATE.

Note The option port is case sensitive. If it contains spaces, it must be bounded by quotes (e.g., ismPortSetSpeed "Cable 1"). Using this command with only the port option displays its current values. A reboot is required to activate changes made with this command. This reboot will be disruptive and will cause the affected switch chips to be reset and have a part of their EEPROM to be reloaded.

ismIslSet12x

Allows the user to view, set and unset the chassis link width to 12X (except external ports).

Syntax:

ismIslSet12x [enable12xBit]

Options:

-enable12xBit

1=enable, 0=disable.

Sample Output:

-> ismIslSet12x.

Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide

 

B-64

OL-8787-05

 

 

 

Image 156
Contents Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Page Preface Logging Snmp Deprecated New and Changed Information Changed Feature Description Release Where Documented Preface Conventions Installation A P T E RStatement 1019-Main Disconnecting Device Statement 1045-Short-circuit Protection Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Page Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Planning the Installation Rack Specifications and RecommendationsUninterruptible Power Supply Cable RequirementsCable Distances Installation Tasks Checklist Safety InformationPrecautions for Rack-Mountable Products Electrical Safety Precautions Protecting Against Electrostatic DischargeCheck the Installation Site Tools, Equipment and Personnel RequiredInstallation Tasks Unpack the EquipmentInstall the Rails in the Rack Mounting Hardware Kit ContentsMounting Kit Mark the RackRack-Mount the Switch Secure Chassis to Rail Installing the Switch Face Plate Installing the Spine and Leaf Modules Removing a Module or BlankConnect Equipment to the Ports and Power On the System LeafLeaf Connecting Power Start-up ProceduresBringing Up the System For the First Time Changing the IP Address and Default Gateway 11 SFS 7012 RS-232 ConnectorUsing the RS232 Serial Port Using Telnet or SSHUsing the Chassis Viewer GUI Click in the Gateway address field Enter the new switch default gateway IP address Click Apply Information similar to the following NEW IP Address SFS 7012 Component LEDs Chassis Status LEDSubnet Manager Agent SMA LED RJ45 LEDsPower Supply LEDs SFS 7012 Leaf and Spine Module LEDsLeaf Module IB Port LEDs Spine and Leaf Module Status LEDShutdown Procedures Hot Swapping ComponentsHot Swapping Spine and Leaf Modules Spine Module Management LEDsHot Swapping Power Supplies Hot Swapping the Fan UnitTighten the captive panel screw Operations and Administration Chassis Viewer Manages HomeDisplaying the Leaf and Spine Module Views ? Help ButtonSupport Button Leaf Module ViewSpine Module View Leaf Module MouseoverLeaf and Spine Module Component Details Area Leaf and Spine Details HeaderLeaf and Spine Information Area Displaying the Chassis View ApplyRefresh Rebooting Components from Chassis Viewer Chassis View Component Details AreaChassis Details Header Chassis View Component Information Area Chassis View Component Information Area TabsLEDs and Sensors Tab System TabPower Tab Chassis FRU TabModifying Switch Component Information Fan TabBackplane Tab StatusChassis View Menu LoggingSet Level 23 Log System Configurator Device Tab Preset Tab Configure Syslog on a Linux Server Syslog TabType /etc/init.d/syslog restart, and press Enter Reset Log Levels 27 Reset Levels ButtonMaintenance Firmware UpdateLdap Configuration 32 Ldap Configuration ButtonHTTP/CLI Session Configuration 34 HTTP/CLI Session Configuration ButtonTarget Configuration SnmpTarget Configuration Window Field Descriptions Snmp Target AddressesSnmp Target Parameters Filter Status Setting Community Strings 40 Filter Status ButtonConfiguration File Administration Administer46 Configuration File Administration Screen Host Upload/DownloadDownload saved configuration files from the CMU to a server Click Config File Admin Trap ControlChassis Traps Chassis GroupIcsChassisTrapSystemSelfTestFailure IcsChassisTrapSystemReboot IcsChassisTrapSystemSwitchFailoverIcsChassisTrapModuleBulkPowerFailure IcsChassisTrapModuleRebootIcsChassisTrapPowerSupplyRemoved IcsChassisTrapPowerSupplyFailedIcsChassisTrapPowerSupplyEEPROMReadFailure IcsChassisTrapPowerSupplyFanFailedInterswitch Link ISL Ports SFS 7012 Port StatisticsUnderstanding Port Naming Conventions Leaf modules/portsPort Statistics Field Descriptions InfiniBand Statistics Leaf and Spine Module IB Port Statistics Leaf ModulesSpine Modules Set Field Thresholds 59 Spine Port Stats MenuPortXmitDataThresh PortRecvDataThreshPortXmitPktsThresh PortRecvPktsThreshTime Service 63 Switch Time Service Click the Use Network Time Protocol? checkboxTime Zone Tips Daylight Saving Time TipsConfiguring the Switch OOB IP Address Configuring the Switch Default Gateway IP AddressFrom the OOB LAN IP submenu, click Set Default Gateway IP Type in the correct switch default gateway IP address Spine View Menu Viewing the LogPurging the Log Select Edit, Copy or Ctrl + CSelect Edit, Paste or Ctrl + Select Boot Image 78 Purge Log Confirmation WindowLicense Keys Key Administration Adding a New License KeyDeleting a License Key Click OK to delete Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide Technical Specifications Table A-1 SFS 7012 Technical Specifications Administrator OperatorCommands and Functional Groups Accessing the CLI Online HelpKeyboard Shortcuts CaptureGroups and Commands Help commandCommand GeneralList List group -noprompt -verboseGroup NopromptReboot HistoryKillCliSession WhoBroadcast Broadcast msgMsg SwapBsDelSetTermWidth GetTermWidthPrompt Rlogin ShowLastRetCodeRcmd ResetCard LogoutUser Passwd UserAddUserRem UserRem usernameUserListShow UserListShowLoginMode SetldapSvrIpAddrIdleTimeoutGet IdleTimeoutSetSetldapSvrPort SessionTimeoutDisable SessionTimeoutEnableLoginMsgGet LoginMsgSet LoginNameGetLoginNameSet SerialAuthGet SerialAuthSetDeprecated ExitExit Chassis HwMonitorShowIBNodeDesc SetIBNodeDesc SetIBNodeDesc New Node StringFruInfo FruInfo slot-allChassisQuery ShowTypeType cardtype IgnoreInvalidTypeShowInventory ShowInventoryNetwork IfShowOptions Sample OutputRouteShow RouteShowPing Ping ipAddress packetCountShowChassisIpAddr ShowChassisIpAddrSetChassisIpAddr SetChassisIpAddr -h ipaddress -m netMaskShowDefaultRoute SetDefaultRouteArpShow HostShow HostShowFwUpdateSlot FwUpdateChassisFirmware FwShowUpdateParams FwListFilesFwSetUpdateParams ShowCapabilityShowLastScpRetCode BootQuery BootQuery slot -active -alternate -allFwVersion FwVersion slotBootSelect ActiveAlternate IndexSmConfig SubnetManagementSmControl SmConfig SmShowLidsSmShowLids Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide SmShowPriority SmSetPrioritySmSetSweepRate BmSetSweepRate SmForceSweepBmForceSweep SmShowServices SmShowServicesSmShowGroups SmShowGroups -hSmShowSubscriptions SmShowSubscriptionsSmShowMasterLMC SmShowMasterLMCSmSetMasterLMC SmShowMasterLidSmShowLidMap SmSetSwitchLifetime SmShowMaxLidSmSetHoqLife SmSetVLStall SmShowSMParmsSmSetPKey SmShowPKeysSmSetKey SmShowKeySmSetMKey SmOptionConfig SmShowMKeySmSetDefBcGroup SmShowDefBcGroupSmSetGidPrefix SmShowGidPrefixSmSetSubnetSize Log SmShowSubnetSizeSmShowSubnetSize LogShowLogConfigure LogConfigureLogClear LogClearLogResetToDefaults LogResetToDefaultsLogSyslogConfig LogSyslogConfig -h xxx.xxx.xxx.xxx -p xxxx -fLogShowConfig LogShowConfigKeyManagement ShowKeysShowKeys IbSwitchInfo AddKeyRemoveKey IsmPortStats ColsLeaf SpineIsmPortCounters IsmPortCounters -clear -active -errors -potential -noprompt ErrorsPotential IsmLinearFwdbIsmLinearFwdb switch SwitchIsmMultiFwdb switch IsmMultiFwdbIsmPortSet12x IsmChassisSet12x enable12xBit IsmChassisSet12xIsmPortEnable IsmPortEnable portIsmChassisSetSpeed IsmChassisSetSpeed speedIsmChassisSetEnable IsmChassisSetEnable enableIsmPortDisable IsmPortDisable portIsmIslSet12x enable12xBit IsmPortSetSpeedIsmPortSetSpeed port speed IsmIslSet12xIsmChassisSetMtu IsmChassisSetMtu mtuIsmIslSetSpeed IsmIslSetSpeed speedFlagIsmShowPStatThresh IsmShowPStatThreshIsmSetPStatThresh IsmSetPStatThresh field thresholdField ThresholdCisco SFS 7012 InfiniBand Server Switch Hardware Users Guide TimeManagement TimeTimeZoneConf TimeNtpTimeout TimeNtpTimeout numSecondsTimeDSTConf TimeDSTConf sw sd sm ew ed emNumSeconds TimeNtpRefreshTimeTimeNtpRefreshTime numSeconds SnmpCommunityConf SnmpCommunityConf -r readonlycommstr -w readwritecommstrSnmpTargetAddr Show AddEdit DeleteSnmpTargetParams Displays the snmpTargetParamsTable entriesSnmpNotifyProfile Displays the snmpNotifyFilterProfileTable entriesSnmpNotifyFilter Displays the snmpNotifyFilterTable entriesSnmpNotifyFilter show SnmpNotifySnmpSystem SnmpUsrSecSnmpUsrSec add show edit delete name -a algo key Capture CaptureCapture CaptureFw CaptureLogCaptureSm CaptureIsmCaptureChassis CaptureNetworkCaptureMisc CaptureSnmp CaptureSnmpCaptureShell CaptureShellSwitch Power SupplyProblem Fix SFS 7012 Leaf Module IB Ports Problem Fix OOB Ethernet RJ45 PortSymptoms Resolution / WorkaroundInfiniBand Invalid IP Address entered via Console PortCisco SFS 7012 InfiniBand Server Switch Hardware Users Guide