Cisco Systems 3560-C manual Enter an enable secret password, and press Return, Plain text

Page 90

Appendix C Configuring the Switch with the CLI Setup Program

Entering the Initial Configuration Information

 

 

 

Step 3

Enter an enable secret password, and press Return.

 

 

 

 

The password can be from 1 to 25 alphanumeric characters, can start with a number, is case sensitive,

 

 

 

 

allows spaces, but ignores leading spaces. The secret password is encrypted, and the enable password is

 

 

 

 

in plain text.

 

 

 

 

Enter enable secret: secret_password

 

 

 

Step 4

Enter an enable password, and press Return.

 

 

 

 

Enter enable password: enable_password

 

 

 

Step 5

Enter a virtual terminal (Telnet) password, and press Return.

 

 

 

 

The password can be from 1 to 25 alphanumeric characters, is case sensitive, allows spaces, but ignores

 

 

 

 

leading spaces.

 

 

 

 

Enter virtual terminal password: terminal-password

 

 

 

Step 6

(Optional) Configure Simple Network Management Protocol (SNMP) by responding to the prompts.

 

 

 

 

You can also configure SNMP later through the CLI. To configure SNMP later, enter no.

 

 

 

 

Configure SNMP Network Management? [no]: no

 

 

 

Step 7

Enter the interface name (physical interface or VLAN name) of the interface that connects to the

 

 

 

 

management network, and press Return. For this release, always use vlan1 as that interface.

 

 

 

 

Enter interface name used to connect to the

 

 

 

 

management network from the above interface summary: vlan1

 

 

 

Step 8

Configure the interface by entering the switch IP address and subnet mask and pressing Return. The IP

 

 

 

 

address and subnet masks shown below are examples.

 

 

 

 

Configuring interface vlan1:

 

 

 

 

Configure IP on this interface? [yes]: yes

 

 

 

 

IP address for this interface: 10.4.120.106

 

 

 

 

Subnet mask for this interface [255.0.0.0]: 255.0.0.0

 

 

 

Step 9

Enter Y to configure the switch as the cluster command switch. Enter N to configure it as a member

 

 

 

 

switch or as a standalone switch.

 

 

 

 

If you enter N, you can configure the switch as a command switch later through the CLI. To configure

 

 

 

 

it later, enter no.

 

 

 

 

Would you like to enable as a cluster command switch? [yes/no]: no

 

 

 

 

You have completed the initial configuration of the switch, and the switch displays its configuration.

 

 

 

 

This is an example of the configuration output:

 

 

 

 

The following configuration command script was created:

 

 

 

 

hostname switch1

 

 

 

 

enable secret 5 $1$Ulq8$DlA/OiaEbl90WcBPd9cOn1

 

 

 

 

enable password enable_password

 

 

 

 

line vty 0 15

 

 

 

 

password terminal-password

 

 

 

 

no snmp-server

 

 

 

 

!

 

 

 

 

 

no ip routing

 

 

 

 

!

 

 

 

 

 

interface Vlan1

 

 

 

 

no shutdown

 

 

 

 

ip address 10.4.120.106 255.0.0.0

 

 

 

 

!

 

 

 

 

 

interface FastEthernet1/0/1

 

 

 

Catalyst 3560-C and 2960-C Switch Hardware Installation Guide

 

 

 

 

 

 

 

 

 

 

C-8

 

 

OL-23803-02

 

 

 

 

 

Image 90
Contents Americas Headquarters Text Part Number OL-23803-02Page N T E N T S Switch Installation Switch LEDs OL-23803-02 Preface Obtaining Documentation and Submitting a Service Request Related PublicationsSwitch Models Switch Model DescriptionFront Panel 3 4 Catalyst 3560CPD-8PT-S Front Panel View PoE Ports Switches with PoE Ports 10/100 and 10/100/1000 Fast Ethernet Downlink PortsPoE Pass-Through PoE Pass-Through PoE Budgeting for the Catalyst 2960CPD-8PT-L SFP Modules USB Type a PortDual-Purpose Ports GLC-FE-100FX= GLC-FE-100LX= GLC-FE-100BX-D=Management Ports USB Mini-Type B PortSwitch Panel LEDs LEDsColor System Status System LEDConsole LEDs Color DescriptionModes for Port LEDs Port Mode DescriptionPort status Port status. This is the default mode Port LEDsPoE LED Dual-Purpose Port LEDsColor Meaning Security slot Power adapter connector Reset button Rear PanelInternal Power Supply Auxiliary Power AdapterAuxiliary power adapter Reset Button Management OptionsSecurity Slots Network Configurations Cisco IOS CLISwitch Installation Preparing for InstallationStatement Installation Guidelines Powering the Switch Box ContentsEquipment That You Supply Verifying Switch Operation Mounting the SwitchOn a Desk or Shelf without Mounting Screws Desk, Shelf, or Wall with Mounting ScrewsDesk- or Shelf-Mounting Installing the Mounting Screws on Top of a Desk or a Shelf Mounting the Switch on Top of a Desk or Shelf Under the Desk- or Shelf-MountingInstalling the Mounting Screws Under a Desk or Shelf Desk or shelf Screws Screw template AdhesiveWall-Mounting Desk or shelf Slides on this way77 in .49 cm 72 in .44 cm 46. 62 in .19 cm Switch Location of the Mounting Holes on the SwitchInstalling the Mounting Screws on the Wall With a Mounting Tray Mounting Tray with ScrewsSwitch Mounting tray Sliding direction Desk Installing the Switch on the Mounting TraySwitch Number-10 Phillips pan-head screws Mounting Tray with a MagnetPlace the switch on the mounting tray. See Figure 11 Placing the Switch on the Mounting Tray13 Wall-Mounting with a Magnet Attaching Brackets to the Switch A RackPhillips flat-head screw Mounting the Switch in a Rack 15 Attaching the 23-inch Brackets for Rack-MountingSwitch DIN rail mount Attaching the DIN-Mount Tray to the SwitchPlace the switch on the DIN rail mount. See Figure On a DIN RailMounting the Switch on a DIN Rail 18 Securing the DIN-Mount Tray to the Switch19 Mounting the Switch on a DIN Rail Removing the Switch from a DIN Rail Installing a Cover for the Reset Button Optional Switch Reset button coverInstalling the Power Cord Retainer Optional 23 Inserting the Retainer through the Lanced LoopAC power cord Latches Sleeve for thin power cords Slide the retainer through the first latch. See Figure26 Sleeve Around the Power Cord Installing the Cable Guard Optional Washer29 Attaching the Cable Guard to the Switch 31 Attaching the Cables to the Switch After Installing the Switch Installing SFP ModulesNumber-8 Phillips wood screws Desk or shelf Insert a dust plug into the optical ports of the SFP module Removing SFP ModulesTX and which is receive RX Grasp the SFP module, and carefully remove it from the slotConnecting Devices to the Ethernet Ports Connecting to the 10/100 and 10/100/1000 PortsBale clasp Connecting to the PoE Ports Device Crossover CableWhere to Go Next OL-23803-02 Diagnosing Problems Switch Post ResultsBad or Damaged Cable Switch LEDsSwitch Connections Ethernet and Fiber-Optic Cables10/100 PoE or PoE+ Port Connections Interface Settings10/100 and 10/100/1000 Port Connections SFP ModuleSpeed, Duplex, and Autonegotiation Switch PerformanceSpanning Tree Loops Autonegotiation and Network Interface CardsResetting the Switch Finding the Switch Serial NumberSerial Number Location for the Catalyst 3560CPD-8PT-S Switch 330039 OL-23803-02 Technical Specifications Environmental RangesEnvironmental Ranges Physical Specifications Power Requirements Table A-2 Catalyst 3560-C and 2960-C Switch Specifications Switch Available PoEOL-23803-02 Connector Specifications 10/100 and 10/100/1000 PortsSFP Module Connectors Figure B-2 10/100/1000 Port PinoutsCables and Adapters SFP Module CablesCore Modal Wavelength Cable Pinouts TP3Switch Console RJ-45-to-DB-9 Port DTE Console Port Adapter PinoutsDevice Switch Console RJ-45-to-DB-25 Port DTE Adapter Device TxD RxDRxD TxD Accessing the CLI Through the Console Port RJ-45 Console PortFigure C-1 Connecting the Console Cable Figure C-2 Connecting the USB-Mini Console Cable USB Mini-Type B Console PortInstalling the Cisco Microsoft Windows USB Device Drivers Installing the Cisco Microsoft Windows XP USB DriverInstalling the Cisco Microsoft Windows 2000 USB Driver Uninstalling the Cisco Microsoft Windows USB Drivers Using the Add or Remove Programs UtilityEntering the Initial Configuration Information IP SettingsCompleting the Setup Program Enter a virtual terminal Telnet password, and press Return Enter an enable secret password, and press ReturnEnter an enable password, and press Return Switch or as a standalone switchThese choices appear OL-23803-02