Cisco Systems 2600 manual Procedure for the tftpdnld Command

Page 91

Appendix B Using the ROM Monitor

Recovering Cisco IOS Software Images

Procedure for the tftpdnld Command

Step 1 Specify the required variables, for example:

rommon 1> IP_ADDRESS=172.15.19.11 rommon 2> IP_SUBNET_MASK=255.255.255.0 rommon 3> DEFAULT_GATEWAY=172.16.19.1 rommon 4> TFTP_SERVER=172.15.20.10 rommon 5> TFTP_FILE=/tftpboot/c2600-i-mz

The syntax for specifying the variables is:

VARIABLE_NAME=value

The variables that you must specify include the following:

IP_ADDRESS—IP address for the router you are using.

IP_SUBNET_MASK—Subnet mask for the router you are using.

DEFAULT_GATEWAY—Default gateway for the router you are using (not required if the TFTP server is in the same subnet as the router).

TFTP_SERVER—IP address of the server from which you want to download the image file.

TFTP_FILE—Name of the file that you want to download.

The following tftpdnld command variables are optional:

TFTP_VERBOSE—Print setting. The default is 1.

0=quiet—After you enter the tftpdnld command, the prompt

Do you wish to continue? y/n:

is the only information that appears until the command completes successfully or fails.

1=progress—Displays the state of the required tftpdnld command variables. Also displays progress characters to indicate successful and lost packet transmissions.

2=verbose—Displays all progress print setting messages, along with error information. The information provided by this print setting may be useful when debugging interface link and configuration problems that may prevent connecting to the TFTP server.

TFTP_RETRY_COUNT—Number of times from 1 to 65535 that the ROM monitor will retry address resolution protocol (ARP) and acknowledge (ACK). The default is 7 retries.

TFTP_TIMEOUT—Overall timeout of the download operation in seconds. The range is from

1to 65535 seconds. The default is 7200 seconds.

TFTP_CHECKSUM—Performs a checksum test on the image. 0=checksum off, 1=checksum on. The default is 1.

FE_SPEED_MODE—Sets the Fast Ethernet speed and duplex mode. 0=10 Mbps half-duplex mode, 1=10 Mbps full-duplex mode, 2=100 Mbps half-duplex mode, 3=100 Mbps full-duplex mode, and 4=auto-negotiation. The default is 4.

Note Specify the FE_SPEED_MODE variable only for routers with a Fast Ethernet network interface.

TR_SPEED_MODE—Sets the Token Ring speed and duplex mode. 0=4 Mbps half-duplex mode, 1=4 Mbps full-duplex mode, 2=16 Mbps half-duplex mode, and 3=16 Mbps full-duplex mode. The default is 2.

Cisco 2600 Series Routers Hardware Installation Guide

 

OL-2171-06

B-11

 

Image 91
Contents Corporate Headquarters Cisco 2600 Series Routers Hardware Installation GuideCisco 2600 Series Routers Hardware Installation Guide Iii N T E N T SSerial DTE or DCE Devices Initial Configuration Using the Setup Command Facility Procedure for the tftpdnld Command Configuration Register Vii ObjectivesChapter Title Description AudienceOrganization ConventionsBewaar Deze Instructies Safety WarningsAvvertenza Importanti Istruzioni Sulla Sicurezza Warnung Wichtige SicherheitshinweiseGuarde Estas Instruções Aviso Instruções Importantes DE SegurançaXii GEM Disse AnvisningerXiii Xiv Related DocumentationCisco Product Document Title Xvi Cisco 90-Day Limited Hardware Warranty TermsDuration of Hardware Warranty Replacement, Repair, or Refund Policy for HardwareOrdering Documentation Obtaining DocumentationDocumentation Feedback Cisco.comXviii Submitting a Service RequestObtaining Technical Assistance Cisco Technical Support WebsiteObtaining Additional Publications and Information Definitions of Service Request SeverityXix Preface Obtaining Additional Publications and Information Overview of Cisco 2600 Series Routers Hardware FeaturesCisco AdvancedReading the Front-Panel LEDs PowerSYS/RPS RPSActivity PWRACT Reading the Rear-Panel LEDsCisco 2613-Rear-Panel LEDs ACT LinkFDX CF1 Modules, Interface Cards, and MemoryWAN and LAN Interface Numbering Interface Numbering11 Interface Numbering in Chassis with 1-RU Height Description Specification System SpecificationsVoice Interface Numbering Regulatory Compliance Safety with Electricity Safety RecommendationsPreventing Electrostatic Discharge Damage Site Environment Power Supply ConsiderationsPower Source Input Power Tolerance Limits General Site RequirementsSite Configuration Installation ChecklistEquipment Racks Task Verified by Date Creating a Site LogInspecting the Router Tools and Equipment for Installation and MaintenanceConsole Port Connections Console and Auxiliary Port ConsiderationsAuxiliary Port Connections Preparing to Connect to a NetworkToken Ring Connections Ethernet ConnectionsSerial Connections Configuring Serial ConnectionsSerial DTE or DCE Devices Distance Limitations Signaling Standards SupportedDevice Type Gender Typical Devices Distance EIA-530 Distance Rate bps Feet Meters Isdn BRI ConnectionsAsynchronous/Synchronous Serial Module Baud Rates EIA/TIA-232Low-Capacitance Cable 56-K/Switched-56-kbps DSU/CSU ConnectionsOL-2171-06 Installing the Router For AIMs Installing Modules, Interface Cards, and Power SuppliesFor network modules For WICs and VICsFor external power supplies Setting Up the ChassisSetting the Chassis on a Desktop For internal power suppliesMounting the Chassis in a Rack Right To the other side of the chassis. Brackets for 19-inch rack Brackets for 19-inch rack To the other side of the chassis Use two screws on each side For 19-inch rack Right bracket Attaching the Brackets to a Router of 2-RU HeightV0 EN Installing the Router in a RackAttaching Rubber Feet to the Router Mounting the Chassis on the WallAttaching Wall-Mount Brackets to the Router 16 Attaching the Wall-Mount Brackets Mounting the Router on the Wall17 Mounting the Chassis on the Wall Installing the Chassis Ground ConnectionRing terminal Connecting Routers to AC Power Power Connections15A, 120VAC 10A, 240VAC. Statement Connecting Routers to a DC-Input Power SupplyDC Wiring Requirements Router DC Input DC Input Wire Size1Wiring Procedure for DC Input Port or Connection Port Type, Color Connected To Cable Connecting WAN, LAN, and Voice CablesConnecting Routers to the Cisco Redundant Power System Ports and CablingLAN, WAN, and Voice Connection Procedures Connecting to the Console Port Connecting to a Console Terminal or Modem23 Connecting to a Console Terminal Connecting to the Auxiliary PortIdentifying a Rollover Cable 24 Connecting a Modem to the Auxiliary PortRouters with 1-RU Chassis Height Powering Up the RouterChecklist for Power Up Front Panel IndicatorsRouters with 2-RU Chassis Height Power-Up ProcedureConfiguring the Router Initial Configuration Using the Setup Command Facility Initial Configuration Using SDMEnter a hostname for the router this example uses Configuration is displayed Initial Configuration Using the CLI Manual ConfigurationTo proceed with manual configuration using the CLI, enter no OL-2171-06 Isolating Problems TroubleshootingEnvironmental Reporting Features Troubleshooting the Power and Cooling SystemsTroubleshooting Modules, Cables, and Connections System Messages Recovering a Lost PasswordCisco Technical Assistance Center Entering ROM Monitor Mode Using the ROM MonitorEnter ROM Monitor Mode by Using the reload Command ROM Monitor CommandsCommand abc ROM Monitor Command Syntax ConventionsRouter Management Commands ROM Monitor Command DescriptionsBoot Commands in the ROM Monitor Informational Commands in the ROM Monitor Other Useful ROM Monitor Commands Debugging CommandsModifying the Configuration Register in Menu Mode Configuration Register CommandsModifying the Configuration Register by Hexidecimal Entry Recovering Cisco IOS Software ImagesConsole Requirements Copying an Image from the Console Using the xmodem CommandDescription and Options of the xmodem Command Procedure for the xmodem CommandRestrictions on the tftpdnld Command Specify the required variables, for example Procedure for the tftpdnld CommandDEFAULTGATEWAY=172.16.19.1 Bit Number Hexadecimal Meaning Configuration Register SettingsNvram Changing Configuration Register Settings Boot Field Meaning Configuring the Boot FieldBit Address net host Baud Bit Enabling Booting from Flash MemoryOL-2171-06 IN-1 NumericsIN-2 DramIN-3 Isdn BRILAN Link LEDIN-4 SdramIN-5 IN-6
Related manuals
Manual 14 pages 1.11 Kb Manual 52 pages 58.61 Kb Manual 18 pages 19.61 Kb Manual 38 pages 43.83 Kb