Cisco Systems 2600 manual Changing Configuration Register Settings

Page 94

Appendix C Configuration Register

Changing Configuration Register Settings

Table C-1 Configuration Bit Meanings (continued)

Bit

 

 

Number

Hexadecimal

Meaning

 

 

 

10

0x0400

IP broadcast with all zeros.

 

 

 

5, 11, 12

0x0020,

Console line speed.

 

0x0800, 0x1000

 

 

 

 

13

0x2000

Boots default ROM software if the network boot fails.

 

 

 

14

0x4000

IP broadcasts do not have net numbers.

 

 

 

15

0x8000

Enables diagnostic messages and ignores the contents

 

 

of NVRAM.

 

 

 

Changing Configuration Register Settings

You might want to modify the value in the configuration register to perform the following tasks:

Recover a lost password

Change the console data rate

Enable or disable the Break function

Manually boot the operating system using the b command at the ROM monitor prompt

Force the router to automatically boot its system image in flash memory, or boot in accordance with any boot system commands stored in the router’s configuration file in NVRAM

You can change the configuration register from either the ROM monitor or the operating system software. To change the configuration register from the ROM monitor, see the “Configuration Register Commands” section on page B-7. To change the configuration register from the system software, do the following:

Step 1 Connect a console terminal to the console port of the router as described in the “Connecting to the

Console Port” section on page 3-20, using the blue RJ-45 to DB-9 console adapter cable.

Note If you have a terminal with a DB-25 port, use an RJ-45 rollover cable and DB-25 adapter. The RJ-45-to-DB-25 adapter (Cisco part number 29-0810-01) can be purchased from Cisco.

For information about cable pinouts, refer to the online document Cisco Modular Access Router Cable Specifications. This document is available online and on the Cisco Documentation CD-ROM.

Step 2 Configure your terminal or terminal emulation software for 9600 baud (default), 8 data bits, no parity, and 1 stop bit.

Step 3 Power on the router.

Step 4 When asked if you would like to enter the initial dialog, answer no:

Would you like to enter the initial dialog? [yes]: no

Your router is now in the normal operating mode.

Step 5 After a few seconds, you see the user EXEC prompt (Router>). Enter the enable command and your password to enter privileged EXEC mode:

Cisco 2600 Series Routers Hardware Installation Guide

 

C-2

OL-2171-06

 

 

 

Image 94 Contents
Cisco 2600 Series Routers Hardware Installation Guide Corporate HeadquartersCisco 2600 Series Routers Hardware Installation Guide N T E N T S IiiSerial DTE or DCE Devices Initial Configuration Using the Setup Command Facility Procedure for the tftpdnld Command Configuration Register Objectives ViiConventions AudienceOrganization Chapter Title DescriptionSafety Warnings Bewaar Deze InstructiesWarnung Wichtige Sicherheitshinweise Avvertenza Importanti Istruzioni Sulla SicurezzaAviso Instruções Importantes DE Segurança Guarde Estas InstruçõesGEM Disse Anvisninger XiiXiii Related Documentation XivCisco Product Document Title Replacement, Repair, or Refund Policy for Hardware Cisco 90-Day Limited Hardware Warranty TermsDuration of Hardware Warranty XviCisco.com Obtaining DocumentationDocumentation Feedback Ordering DocumentationCisco Technical Support Website Submitting a Service RequestObtaining Technical Assistance XviiiObtaining Additional Publications and Information Definitions of Service Request SeverityXix Preface Obtaining Additional Publications and Information Hardware Features Overview of Cisco 2600 Series RoutersAdvanced CiscoPower Reading the Front-Panel LEDsPWR RPSActivity SYS/RPSReading the Rear-Panel LEDs ACTCisco 2613-Rear-Panel LEDs ACT LinkFDX Modules, Interface Cards, and Memory CF1Interface Numbering WAN and LAN Interface Numbering11 Interface Numbering in Chassis with 1-RU Height Description Specification System SpecificationsVoice Interface Numbering Regulatory Compliance Safety Recommendations Safety with ElectricityPreventing Electrostatic Discharge Damage General Site Requirements Power Supply ConsiderationsPower Source Input Power Tolerance Limits Site EnvironmentSite Configuration Installation ChecklistEquipment Racks Creating a Site Log Task Verified by DateTools and Equipment for Installation and Maintenance Inspecting the RouterConsole and Auxiliary Port Considerations Console Port ConnectionsPreparing to Connect to a Network Auxiliary Port ConnectionsEthernet Connections Token Ring ConnectionsSerial Connections Configuring Serial ConnectionsSerial DTE or DCE Devices Distance Limitations Signaling Standards SupportedDevice Type Gender Typical Devices EIA/TIA-232 Isdn BRI ConnectionsAsynchronous/Synchronous Serial Module Baud Rates Distance EIA-530 Distance Rate bps Feet Meters56-K/Switched-56-kbps DSU/CSU Connections Low-Capacitance CableOL-2171-06 Installing the Router For WICs and VICs Installing Modules, Interface Cards, and Power SuppliesFor network modules For AIMsFor internal power supplies Setting Up the ChassisSetting the Chassis on a Desktop For external power suppliesMounting the Chassis in a Rack Right To the other side of the chassis. Brackets for 19-inch rack Brackets for 19-inch rack To the other side of the chassis Attaching the Brackets to a Router of 2-RU Height Use two screws on each side For 19-inch rack Right bracketInstalling the Router in a Rack V0 ENAttaching Rubber Feet to the Router Mounting the Chassis on the WallAttaching Wall-Mount Brackets to the Router Mounting the Router on the Wall 16 Attaching the Wall-Mount BracketsInstalling the Chassis Ground Connection 17 Mounting the Chassis on the WallRing terminal Power Connections Connecting Routers to AC PowerRouter DC Input DC Input Wire Size1 Connecting Routers to a DC-Input Power SupplyDC Wiring Requirements 15A, 120VAC 10A, 240VAC. StatementWiring Procedure for DC Input Ports and Cabling Connecting WAN, LAN, and Voice CablesConnecting Routers to the Cisco Redundant Power System Port or Connection Port Type, Color Connected To CableLAN, WAN, and Voice Connection Procedures Connecting to a Console Terminal or Modem Connecting to the Console PortConnecting to the Auxiliary Port 23 Connecting to a Console Terminal24 Connecting a Modem to the Auxiliary Port Identifying a Rollover CableFront Panel Indicators Powering Up the RouterChecklist for Power Up Routers with 1-RU Chassis HeightPower-Up Procedure Routers with 2-RU Chassis HeightConfiguring the Router Initial Configuration Using SDM Initial Configuration Using the Setup Command FacilityEnter a hostname for the router this example uses Initial Configuration Using the CLI Manual Configuration Configuration is displayedTo proceed with manual configuration using the CLI, enter no OL-2171-06 Troubleshooting Isolating ProblemsTroubleshooting the Power and Cooling Systems Environmental Reporting FeaturesTroubleshooting Modules, Cables, and Connections System Messages Recovering a Lost PasswordCisco Technical Assistance Center Using the ROM Monitor Entering ROM Monitor ModeROM Monitor Commands Enter ROM Monitor Mode by Using the reload CommandROM Monitor Command Syntax Conventions Command abcRouter Management Commands ROM Monitor Command DescriptionsBoot Commands in the ROM Monitor Informational Commands in the ROM Monitor Debugging Commands Other Useful ROM Monitor CommandsConfiguration Register Commands Modifying the Configuration Register in Menu ModeRecovering Cisco IOS Software Images Modifying the Configuration Register by Hexidecimal EntryProcedure for the xmodem Command Copying an Image from the Console Using the xmodem CommandDescription and Options of the xmodem Command Console RequirementsRestrictions on the tftpdnld Command Procedure for the tftpdnld Command Specify the required variables, for exampleDEFAULTGATEWAY=172.16.19.1 Bit Number Hexadecimal Meaning Configuration Register SettingsNvram Changing Configuration Register Settings Configuring the Boot Field Boot Field MeaningBit Address net host Enabling Booting from Flash Memory Baud BitOL-2171-06 Numerics IN-1Dram IN-2Link LED Isdn BRILAN IN-3Sdram IN-4IN-5 IN-6
Related manuals
Manual 104 pages 30.17 Kb Manual 14 pages 1.11 Kb Manual 52 pages 58.61 Kb Manual 18 pages 19.61 Kb Manual 38 pages 43.83 Kb