Cabletron Systems WPIM-RT1 manual 2 T1 Interface Configuration

Page 35

Full T1 Configuration Using PPP

7.Use the arrow keys to highlight T1 TX Clock Source. Press the SPACE bar to select Local (no clock source provided by telephone company) or Loop (clock source provided by telephone company), then press ENTER.

If you are using a Local clock source, set only one end of the

!circuit for Local, and the other end must be set for Loop.

CAUTION

8.Use the arrow keys to highlight T1 Line Buildout (LBO). Press the SPACE bar to select 0 dB unless the service provider recommends another setting, then press ENTER.

9.Use the arrow keys to highlight T1 Network Loopback. Press the SPACE bar to select None, then press ENTER.

10.Use the arrow keys to highlight the SAVE command, then press ENTER. The message “SAVE DONE!” displays and Local Management saves the changes to memory. “REBOOT IN PROGRESS......” displays and the host platform reboots. Re-entry to management is necessary for any further configuration.

11.Proceed to Section 3.3.2 to continue configuration.

3.3.2T1 Interface Configuration

The WAN Interface Configuration screen is accessed through the WAN Physical Configuration screen. Access the WAN Interface Configuration screen by using the arrow keys to highlight the WAN INT CONFIG command and press ENTER. Refer to Figure 3-4and proceed with the following steps to configure the WAN Interface.

1.Set the WAN connection Interface Number by typing the same number into the Interface Number field that was input into the timeslots in the WAN Physical Configuration screen, then press ENTER (see the Notes on page 3-12).

2.Unless the user sets the Max Xmit Unit, the WPIM-RT1 automatically sets the Max Xmit Unit to 1526 (default for PPP) after the protocol manager type is selected.

3.Make any changes to the available settings as desired.

WPIM-RT1 User’s Guide

3-13

Image 35
Contents WPIM-RT1 Page WPIM-RT1 User’s Guide FCC NoticeVcci Notice Industry Canada NoticeCabletron Software Program License Exclusion of Warranty and Disclaimer of LiabilityCabletron SYSTEMS, INC. Program License Agreement United States Government Restricted Rights PO Box Rochester, NH Declaration of ConformityWPIM-RT1 User’s Guide Contents Viii WPIM-RT1 User’s Guide Structure of this Guide Using this ManualIntroduction Related Manuals Following conventions are used throughout this document Document ConventionsYour email address Getting HelpChapter Overview MIB Support WPIM-RT1 FeaturesWAN Protocols IsdnInstalling the WPIM-RT1 Chapter Setup and InstallationUnpacking the WPIM-RT1 Pre-InstallationInstalling the WPIM-RT1 Installing the WPIM-RT1 Post-InstallationRequired Management Operations Connecting the WAN Cable to the WPIM-RT1Host Platform LEDs Connecting the WAN cable to the WPIM-RT1 WPIM-RT1 User’s Guide Chapter Local Management WAN Physical Configuration Screen Fields WAN Physical Configuration ScreenDisplays the next interface available to be used Wpim Line Configuration Fields Sample Timeslot Configuration Wpim Timeslot Configuration TableSample Configuration WAN Interface Configuration Screen Fields WAN Interface Configuration ScreenFrame Relay as the Protocol Manager WAN Interface Configuration Screen PPP PPP as the Protocol ManagerCommand Fields and Interface Table Fields Configuration Information Required by User Full T1 Configuration Using PPP1 T1 Physical Configuration 2 T1 Interface Configuration Fractional T1 Configuration Fractional T1 Configuration Using PPPFractional T1 Configuration Using PPP Enter Frame Relay Configuration Frame Relay ConfigurationFrame Relay Physical Configuration Frame Relay Configuration Frame Relay Interface Configuration Frame Relay Configuration WPIM-RT1 User’s Guide Regulatory Compliance Appendix a SpecificationsPhysical Properties Environmental RequirementsCable Assemblies and Pinouts T1 Interface CablingREN/SOC FIC Usoc Appendix B FCC Part 68 USER’S InformationAppendix B FCC Part 68 User’s Information Being duly sworn, state My commission expires