Cabletron Systems TRXI-42, TRXI-22 Attenuation and Impedance, Frequency Impedance Attenuation

Page 13

REQUIREMENTS/SPECIFICATIONS

2.1.1UTP Cable Specifications for the TRXI-22/24 Lobe Ports and TPIM-T2

The TRXI-22 and TRXI-24 lobe ports and the TPIM-T2 support voice grade Unshielded Twisted Pair (UTP) cable, as described in EIA/TIA TSB 568, and IBM Type 3 cable.

UTP consists of four pairs of 24 AWG solid wire for data or voice communication and is typically used to wire cable runs within the walls of buildings. In some installations, existing UTP building wiring can be used for token ring cabling. UTP cable must conform to the limits shown in Table 2-1.

Warning: DO NOT connect UTP cabling to any non-token ring network conductors (telephone, etc.) or ground. If in doubt, test wiring before using. Telephone Battery and Ringing voltages, used in UTP telephone circuits, could present a shock hazard and can damage token ring equipment when connected to token ring cabling.

The increased popularity and cost advantages of UTP cable have driven refinements to UTP cable design. As a result, better grades of UTP cable, known as supergrade or level 4, are available that exhibit improved transmission characteristics. These improved grades of UTP can often be used to permit operation at 16 Mbps on longer lobe cables.

Attenuation and Impedance

The values listed in Table 2-1 include the maximum attenuation of the cables, connectors, patch panels, and reflection losses due to impedance mismatches in the segment.

Table 2-1. UTP Voice Grade and Category 3 Specifications

Frequency

Impedance

Attenuation

 

 

 

 

 

 

 

 

1

MHz

100Ω ±15%

<26 dB/km (8 dB/1000 ft)

 

 

 

 

4

MHz

100Ω ±15%

<56 dB/km (16 dB/1000 ft)

 

 

 

 

10

MHz

100Ω ±15%

<98 dB/km (30 dB/1000 ft)

 

 

 

 

16

MHz

100Ω ±15%

<131 dB/km (40 dB/1000 ft)

 

 

 

 

 

Page 2-2

Image 13
Contents Token Ring Intelligent HUB USER’S Guide Printed On Recycled Paper FCC Notice Exclusion of Warranty and Disclaimer of Liability REQUIREMENTS/SPECIFICATIONS Contents Table of Contents IntroductionInstallation Testing and Troubleshooting ContentsLocal Management Chapter Introduction Using this ManualTrxi Overview Introduction Getting HelpTrxi Features Rmon MIB Support Media Type ConnectorGroup Subgroup Section Token Ring Port Interface Modules TPIMsCabletron’s Distributed LAN Monitor Flash EEPROMsRemote Network Management Capabilities Recommended ReadingCable Specifications Chapter REQUIREMENTS/SPECIFICATIONSFrequency Impedance Attenuation Attenuation and ImpedanceUTP Cable Type Maximum Lobe Length Mbps Maximum Lobe LengthsType 3 Media Filters Maximum Number of StationsREQUIREMENTS/SPECIFICATIONS Maximum Trunk Lengths STP Cable Type Ring Speed MbpsMixed Cable Types Cable Type Attenuation Maximum Drive Distance Multimode Fiber Optic Cable Specifications for the TPIM-F2Fiber Optic Budget Single Mode Fiber Optic Cable Specifications for the TPIM-F3 Crosstalk TemperatureNoise REQUIREMENTS/SPECIFICATIONS Console REQUIREMENTS/SPECIFICATIONS COM 1/COM 2 Port SpecificationsModem UPSTPIM-T1 REQUIREMENTS/SPECIFICATIONS Tpim SpecificationsTPIM-T4 REQUIREMENTS/SPECIFICATIONS TPIM-T2Parameter Typical Worst Worst Case Typical REQUIREMENTS/SPECIFICATIONS TPIM-F2Value Case Budget TPIM-F3 REQUIREMENTS/SPECIFICATIONS TPIM-F3Parameter Typical Minimum Maximum Power Supply Requirements REQUIREMENTS/SPECIFICATIONS General SpecificationsOutput Min. Load Max. Load Max Power Environmental RequirementsService REQUIREMENTS/SPECIFICATIONS SafetyPhysical Attaching the Strain Relief Bracket Unpacking the TrxiAttaching the Strain Relief Installing the TrxiRack Mounting the Trxi Installing the Trxi in the RackWall Mounting the Trxi Free-Standing Installation Ring Speed Switch Settings Installation Setting the Ring Speed SwitchInstallation Setting the Nvram Switch Connecting the Network Lobe Port Cabling Installation Connecting the Trxi to the Power SourceConfiguration Examples for TRXI-24 and TRXI-44 LNK TPIM-T4 Installation Installing the Tpim RI/RO Modules Top View Setting the TPIM’s Phantom Switch and RI/RO Switch12. Installing a Tpim Installing a Tpim to the TrxiConnecting a Twisted Pair Segment to the TPIM-T1 Connecting a Twisted Pair Segment to the TPIM-T2 or TPIM-T4 Installation LNK Finishing the Installation Checking the Installation Chapter Testing and TroubleshootingTRXI-24TOKEN Ring HUB with Lanview Testing and Troubleshooting Using LanviewLCD Testing and Troubleshooting LCD DisplayDisplayed Message Comments Static System MessagesDisplayed Messages Comments Alarm MessagesUnsaved Initialization Messages Failure or Error MessagesNormal Unsaved Initialization Messages Displayed Message Saved System MessagesChapter Local Management Attaching the Management Terminal Local Management Management Terminal RequirementsDisplay Setup Setting the Management Terminal Setup ParametersGeneral Setup SetupRJ45 COM 2 Port Modem Cable Configuration and SetupTrxi Local Management Local Management Accessing Local ManagementMain Menu Local Management Using Local ManagementExiting a Local Management Screen Selecting a Menu OptionExiting Your Local Management Session System Date System Level ScreenSystem Time IP AddressCOM 1 Application Setting the System DateCOM 2 Application Clear All NvramSetting the IP Address Setting the System TimeSetting the Subnet Mask Setting the Enable Beacon Recovery Field Setting the Clear All Nvram FieldSnmp Community Names Screen Component Name AccessCommunity Name Editing the Community Name FieldSnmp Traps Screen Enable TrapsTrap Destination Trap Community NameSetting Snmp Traps Ring Security Screen Station Address Security ModeStn Edit Nextscreen SAVE/EXECUTEPreviousscreen ReturnAdding Stations to the Station Address Allowed List Building the Allowed ListDeleting Stations from the Station Address Allowed List Changing the Ring Security ModeDevice Statistics Device Statistics ScreenInterface Isolating Errors Ring Information NON-ISOLATING Errors Ports EnabledLost Frame Errors Ring NumberRcvr Congestion Errors Frame Copied ErrorsToken Errors Frequency ErrorsSetting the Refresh Field Selecting the Device Statistics Counter ModeChassis Status View Screen Enable All PortsPort Status TempSetting the Operational/Administrative Mode Option Setting the Enable All Ports OptionOperational Return11. Component Status View Screen Component Status View ScreenSnmp Tools Screen SET GETGetnext WalkGetting and Setting OIDs Security Access LevelCommunity Name Local Management Scrolling Through MIB OIDs Local Management Local Management German Power Supply CordSpanish French