REQUIREMENTS/SPECIFICATIONS
2.5GENERAL SPECIFICATIONS
The operating specifications for the TRXI are described in this section. Cabletron Systems reserves the right to change these specifications at any time without notice.
Data Buffer Memory (RAM): | 4 MB (Upgradeable) |
Internal Processor: | Intel 80C960CA at 16 MHz |
Controller: | Texas Instruments TMS380 |
Static RAM: | 32 KB with battery |
EPROM: | 128 KB |
FLASH MEMORY: | 2 MB (Upgradeable) |
POWER SUPPLY REQUIREMENTS
Note: The TRXI has a universal power supply. This unit allows you to use an input power from 85 to 264 VAC,
The power supply has two outputs of +5 volts and +12 volts. The maximum output power is 125 watts and the minimum efficiency is 65% under all conditions of line at full load. The minimum and maximum load current from each output is shown below.
Output | Min. Load | Max. Load | Max Power |
+5 Volts | 1.00 Amps | 15 Amps | 75 Watts |
+12 Volts | 0.15 Amps | 4 Amps | 48 Watts |
ENVIRONMENTAL REQUIREMENTS |
| ||
|
|
| |
Operating Temperature: | +5° to +50°C |
| |
| |||
Operating Humidity: | 5 to 95% |