Cabletron Systems TRXI-44, TRXI-22, TRXI-42, TRXI-24 manual Snmp Community Names Screen

Page 67

LOCAL MANAGEMENT

5.3.2The SNMP Community Names Screen

The SNMP Community Names screen lets you set community names. Community names serve two purposes; they act as passwords to Local Management and they are agents of security control to your TRXI. You control TRXI access by establishing up to three levels of security authorization (Read Only, Read-Write, and Super-User). Only a user with Super-User access can change the device IP address and the community names.

Caution: Community Names are passwords to Local Management. Remember your Community Name.

Local Management passwords accorded Read-Only and Read-Write access privileges are not allowed editing capabilities to some fields. In this case, the message “AUTHORIZATION PROHIBITS ACCESS” appears. Figure 5-6 shows the SNMP Community Names screen.

 

 

 

 

 

 

TRXI LOCAL MANAGEMENT

 

Flash Image Version: X.XX.XX

 

 

 

SNMP COMMUNITY NAMES

 

 

Component Name

Community Name

Access Policy

 

 

TRXI Chassis MGR

public

READ-ONLY

 

 

TRXI Chassis MGR

ring1

READ-WRITE

 

 

TRXI Chassis MGR

<CR>

SUPER-USER

 

 

SAVE

 

RETURN

 

 

 

 

 

 

 

 

 

 

 

Figure 5-6. SNMP Community Names Screen

Page 5-13

Image 67
Contents Token Ring Intelligent HUB USER’S Guide Printed On Recycled Paper FCC Notice Exclusion of Warranty and Disclaimer of Liability REQUIREMENTS/SPECIFICATIONS Contents Table of Contents IntroductionInstallation Testing and Troubleshooting ContentsLocal Management Chapter Introduction Using this ManualTrxi Overview Introduction Getting HelpTrxi Features Token Ring Port Interface Modules TPIMs Media Type ConnectorRmon MIB Support Group Subgroup SectionRecommended Reading Flash EEPROMsCabletron’s Distributed LAN Monitor Remote Network Management CapabilitiesCable Specifications Chapter REQUIREMENTS/SPECIFICATIONSFrequency Impedance Attenuation Attenuation and ImpedanceMaximum Number of Stations Maximum Lobe LengthsUTP Cable Type Maximum Lobe Length Mbps Type 3 Media FiltersREQUIREMENTS/SPECIFICATIONS Maximum Trunk Lengths STP Cable Type Ring Speed MbpsMixed Cable Types Cable Type Attenuation Maximum Drive Distance Multimode Fiber Optic Cable Specifications for the TPIM-F2Fiber Optic Budget Single Mode Fiber Optic Cable Specifications for the TPIM-F3 Crosstalk TemperatureNoise REQUIREMENTS/SPECIFICATIONS UPS REQUIREMENTS/SPECIFICATIONS COM 1/COM 2 Port SpecificationsConsole ModemTPIM-T1 REQUIREMENTS/SPECIFICATIONS Tpim SpecificationsTPIM-T4 REQUIREMENTS/SPECIFICATIONS TPIM-T2Parameter Typical Worst Worst Case Typical REQUIREMENTS/SPECIFICATIONS TPIM-F2Value Case Budget TPIM-F3 REQUIREMENTS/SPECIFICATIONS TPIM-F3Parameter Typical Minimum Maximum Environmental Requirements REQUIREMENTS/SPECIFICATIONS General SpecificationsPower Supply Requirements Output Min. Load Max. Load Max PowerService REQUIREMENTS/SPECIFICATIONS SafetyPhysical Attaching the Strain Relief Bracket Unpacking the TrxiAttaching the Strain Relief Installing the TrxiRack Mounting the Trxi Installing the Trxi in the RackWall Mounting the Trxi Free-Standing Installation Ring Speed Switch Settings Installation Setting the Ring Speed SwitchInstallation Setting the Nvram Switch Connecting the Network Lobe Port Cabling Installation Connecting the Trxi to the Power SourceConfiguration Examples for TRXI-24 and TRXI-44 LNK TPIM-T4 Installation Installing the Tpim RI/RO Modules Top View Setting the TPIM’s Phantom Switch and RI/RO Switch12. Installing a Tpim Installing a Tpim to the TrxiConnecting a Twisted Pair Segment to the TPIM-T1 Connecting a Twisted Pair Segment to the TPIM-T2 or TPIM-T4 Installation LNK Finishing the Installation Checking the Installation Chapter Testing and TroubleshootingTRXI-24TOKEN Ring HUB with Lanview Testing and Troubleshooting Using LanviewLCD Testing and Troubleshooting LCD DisplayDisplayed Message Comments Static System MessagesDisplayed Messages Comments Alarm MessagesUnsaved Initialization Messages Failure or Error MessagesNormal Unsaved Initialization Messages Displayed Message Saved System MessagesChapter Local Management Attaching the Management Terminal Local Management Management Terminal RequirementsSetup Setting the Management Terminal Setup ParametersDisplay Setup General SetupRJ45 COM 2 Port Modem Cable Configuration and SetupTrxi Local Management Local Management Accessing Local ManagementMain Menu Local Management Using Local ManagementExiting a Local Management Screen Selecting a Menu OptionExiting Your Local Management Session IP Address System Level ScreenSystem Date System TimeClear All Nvram Setting the System DateCOM 1 Application COM 2 ApplicationSetting the IP Address Setting the System TimeSetting the Subnet Mask Setting the Enable Beacon Recovery Field Setting the Clear All Nvram FieldSnmp Community Names Screen Editing the Community Name Field AccessComponent Name Community NameTrap Community Name Enable TrapsSnmp Traps Screen Trap DestinationSetting Snmp Traps Ring Security Screen Station Address Security ModeStn Edit Return SAVE/EXECUTENextscreen PreviousscreenAdding Stations to the Station Address Allowed List Building the Allowed ListDeleting Stations from the Station Address Allowed List Changing the Ring Security ModeDevice Statistics Device Statistics ScreenInterface Isolating Errors Ring Information Ring Number Ports EnabledNON-ISOLATING Errors Lost Frame ErrorsFrequency Errors Frame Copied ErrorsRcvr Congestion Errors Token ErrorsSetting the Refresh Field Selecting the Device Statistics Counter ModeTemp Enable All PortsChassis Status View Screen Port StatusReturn Setting the Enable All Ports OptionSetting the Operational/Administrative Mode Option Operational11. Component Status View Screen Component Status View ScreenSnmp Tools Screen Walk GETSET GetnextGetting and Setting OIDs Security Access LevelCommunity Name Local Management Scrolling Through MIB OIDs Local Management Local Management French Power Supply CordGerman Spanish