Cabletron Systems TRXI-44, TRXI-22, TRXI-42, TRXI-24 manual Requirements/Specifications

Page 15

REQUIREMENTS/SPECIFICATIONS

2.1.2STP Cable Specifications For The TRXI-42/44 Lobe Ports and TPIM-T1/T4

The TRXI-42 and TRXI-44 lobe ports support IBM Type 1, 2, 6, and 9 STP cabling as described below:

IBM Type 1 - Two STP lengths of 22 AWG solid wire for data. Used for the longest cable runs within the walls of buildings.

IBM Type 2 - Similar to Type 1 data cable, but having four additional UTP lengths of 22 AWG solid wire carried outside of the shield casing. Typically used for voice communication and often used to wire cable runs within the walls of buildings.

IBM Type 6 - Two STP lengths of 26 AWG stranded wire for data. This type is used in patch panels or to connect devices to/from wall jacks. Attenuation for Type 6 cable is 3/2 x Type 1 cable (66 m of Type 6 =100 meters of Type 1).

IBM Type 9 - Similar to Type 1, but uses 26 AWG solid wire. Attenuation for Type 9 cable is 3/2 x Type 1 cable

(66 m of Type 9 = 100 meters of Type 1).

Attenuation and Impedance

The attenuation values shown in Table 2-3 include the attenuation of the cables, connectors, patch panels, and reflection losses due to impedance mismatches in the segment.

Table 2-3. STP Cable Specifications

Frequency

Impedance

Attenuation

 

 

 

 

 

 

Types 1 & 2

150Ω + 15%

 

4 MHz

<22 dB/km (6.7 db/1000 ft.)

16 MHz

150Ω + 15%

<45 dB/km (13.7 db/1000 ft.)

 

 

 

Types 6 & 9

150Ω + 15%

 

4 MHz

<33 dB/km (10 db/1000 ft.)

16 MHz

150Ω + 15%

<66 dB/km (20 db/1000 ft.)

 

 

 

Page 2-4

Image 15
Contents Token Ring Intelligent HUB USER’S Guide Printed On Recycled Paper FCC Notice Exclusion of Warranty and Disclaimer of Liability Contents Table of Contents Introduction REQUIREMENTS/SPECIFICATIONSInstallation Contents Testing and TroubleshootingLocal Management Chapter Introduction Using this ManualTrxi Overview Introduction Getting HelpTrxi Features Token Ring Port Interface Modules TPIMs Media Type ConnectorRmon MIB Support Group Subgroup SectionRecommended Reading Flash EEPROMsCabletron’s Distributed LAN Monitor Remote Network Management CapabilitiesCable Specifications Chapter REQUIREMENTS/SPECIFICATIONSFrequency Impedance Attenuation Attenuation and ImpedanceMaximum Number of Stations Maximum Lobe LengthsUTP Cable Type Maximum Lobe Length Mbps Type 3 Media FiltersREQUIREMENTS/SPECIFICATIONS Maximum Trunk Lengths STP Cable Type Ring Speed MbpsMixed Cable Types Multimode Fiber Optic Cable Specifications for the TPIM-F2 Cable Type Attenuation Maximum Drive DistanceFiber Optic Budget Single Mode Fiber Optic Cable Specifications for the TPIM-F3 Temperature CrosstalkNoise REQUIREMENTS/SPECIFICATIONS UPS REQUIREMENTS/SPECIFICATIONS COM 1/COM 2 Port SpecificationsConsole ModemTPIM-T1 REQUIREMENTS/SPECIFICATIONS Tpim SpecificationsTPIM-T4 REQUIREMENTS/SPECIFICATIONS TPIM-T2REQUIREMENTS/SPECIFICATIONS TPIM-F2 Parameter Typical Worst Worst Case TypicalValue Case Budget TPIM-F3 REQUIREMENTS/SPECIFICATIONS TPIM-F3Parameter Typical Minimum Maximum Environmental Requirements REQUIREMENTS/SPECIFICATIONS General SpecificationsPower Supply Requirements Output Min. Load Max. Load Max PowerREQUIREMENTS/SPECIFICATIONS Safety ServicePhysical Attaching the Strain Relief Bracket Unpacking the TrxiAttaching the Strain Relief Installing the TrxiRack Mounting the Trxi Installing the Trxi in the RackWall Mounting the Trxi Free-Standing Installation Ring Speed Switch Settings Installation Setting the Ring Speed SwitchInstallation Setting the Nvram Switch Connecting the Network Lobe Port Cabling Installation Connecting the Trxi to the Power SourceConfiguration Examples for TRXI-24 and TRXI-44 LNK TPIM-T4 Installation Installing the Tpim RI/RO Modules Top View Setting the TPIM’s Phantom Switch and RI/RO Switch12. Installing a Tpim Installing a Tpim to the TrxiConnecting a Twisted Pair Segment to the TPIM-T1 Connecting a Twisted Pair Segment to the TPIM-T2 or TPIM-T4 Installation LNK Finishing the Installation Checking the Installation Chapter Testing and TroubleshootingTRXI-24TOKEN Ring HUB with Lanview Testing and Troubleshooting Using LanviewLCD Testing and Troubleshooting LCD DisplayDisplayed Message Comments Static System MessagesDisplayed Messages Comments Alarm MessagesFailure or Error Messages Unsaved Initialization MessagesNormal Unsaved Initialization Messages Displayed Message Saved System MessagesChapter Local Management Attaching the Management Terminal Local Management Management Terminal RequirementsSetup Setting the Management Terminal Setup ParametersDisplay Setup General SetupRJ45 COM 2 Port Modem Cable Configuration and SetupTrxi Local Management Local Management Accessing Local ManagementMain Menu Local Management Using Local ManagementSelecting a Menu Option Exiting a Local Management ScreenExiting Your Local Management Session IP Address System Level ScreenSystem Date System TimeClear All Nvram Setting the System DateCOM 1 Application COM 2 ApplicationSetting the IP Address Setting the System TimeSetting the Subnet Mask Setting the Enable Beacon Recovery Field Setting the Clear All Nvram FieldSnmp Community Names Screen Editing the Community Name Field AccessComponent Name Community NameTrap Community Name Enable TrapsSnmp Traps Screen Trap DestinationSetting Snmp Traps Ring Security Screen Security Mode Station AddressStn Edit Return SAVE/EXECUTENextscreen PreviousscreenAdding Stations to the Station Address Allowed List Building the Allowed ListDeleting Stations from the Station Address Allowed List Changing the Ring Security ModeDevice Statistics Screen Device StatisticsInterface Isolating Errors Ring Information Ring Number Ports EnabledNON-ISOLATING Errors Lost Frame ErrorsFrequency Errors Frame Copied ErrorsRcvr Congestion Errors Token ErrorsSetting the Refresh Field Selecting the Device Statistics Counter ModeTemp Enable All PortsChassis Status View Screen Port StatusReturn Setting the Enable All Ports OptionSetting the Operational/Administrative Mode Option Operational11. Component Status View Screen Component Status View ScreenSnmp Tools Screen Walk GETSET GetnextSecurity Access Level Getting and Setting OIDsCommunity Name Local Management Scrolling Through MIB OIDs Local Management Local Management French Power Supply CordGerman Spanish