Cabletron Systems DELHE-UA manual Connecting a Twisted Pair Segment to the DELTX-UI

Page 34

Chapter 2: Installation

Do not touch the ends of the fiber optic strands, and do not let

!the ends come in contact with dust, dirt, or other contaminants. Contamination of the ends causes problems in data

transmissions. If the ends become contaminated, blow the surfaces clean with a canned duster. A fiber port cleaning swab saturated with optical-grade isopropyl alcohol may also be used to clean the ends.

2.Insert one end of the SC connector into the FEPIM.

3.At the other end of the fiber optic cable, attach the SC connector to the other device.

4.Verify that a link exists by checking that the port receive LED is ON (flashing amber, blinking green, or solid green). If the receive LED is OFF and the transmit LED is not blinking amber, perform the following steps until it is ON:

a.Check that the power is turned on for the device at the other end of the link.

b.Verify proper crossover of fiber strands between the port on the DELHE-UA and the fiber optic device at the other end of the fiber optic link segment.

c.Verify that the fiber connection meets the dB loss specifications outlined in Appendix B.

If a link has not been established, refer to Chapter 3, LANVIEW LEDs, before contacting a DIGITAL representative.

2.4.2Connecting a Twisted Pair Segment to the DELTX-UI

A DELTX-UI has an internal crossover switch. When connecting a workstation, use a straight-through cable and set the FEPIM crossover switch shown in Figure 2-5 to the crossed over position marked with X. When connecting networking devices, such as another bridge, repeater, or router, use a straight-through cable and set the FEPIM crossover switch shown in Figure 2-5 to the straight-through position, marked with =.

2-10

DELHE-UA User’s Guide

Image 34
Contents DELHE-UA Page Digital Fast Ethernet Interface Module United States Government Restricted Rights Achtung Cabletron SYSTEMS, INC. Program License Agreement Page Declaration of Conformity Contents Contents Figures Tables Preface Using this GuideStructure of this Guide Document Conventions Related DocumentationWorld Wide Web CorrespondenceDocumentation Comments Getting HelpPage Safety OverviewSafety Requirements Safety Requirements Xviii DELHE-UA User’s Guide DELHE-UA User’s Guide Xix Das Ende an beiden Seiten des Chapter Introduction ConnectivityLocal Management Full Duplex Switched EthernetLanview Diagnostic LEDs Fepim OptionsChapter Installation Unpacking the DELHE-UAInstalling Fast Ethernet Port Interface Modules Installing Fast Ethernet Port Interface Modules Installing the Fepim Installing the DELHE-UA Installing the DELHE-UA in an Interface ModuleRemoving the Hsim Coverplate Installing the DELHE-UA Connecting to the Network Connecting a Fiber Optic Segment to the Fepim Connecting a Twisted Pair Segment to the DELTX-UI DELTX-UI Crossover Switch Straight-Through Cable Connecting to the Network Page Chapter DELHE-UA LEDsDELTX-UI LED ChapterDELHE-UA Local Management DELHE-UA Local ManagementPage Physical Properties Appendix a DELHE-UA SpecificationsEnvironmental Requirements Regulatory Compliance Appendix B Fepim Specifications DELTX-UIDELFX-UI DELF3-UI Page Page 9032765