4-14. Selecting A Location And Connecting Input Power

18 in (457 mm) of space for airflow

YDo Not cut off power cord connector and rewire. The power cord connector and plugs will work with standard NEMA receptacles. Modifying power cord, connector, and plugs will void product warranty.

9

34

1

5

6

78

2

Ref. 803 862-C

YDo not move or operate unit where it could tip.

YSpecial installation may be required where gasoline or volatile liquids are present − see NEC Article 511 or CEC Section 20.

For 115 volts ac input power, a 15 or 20 ampere individual branch circuit protected by time-delay fuses or circuit breaker is required. For 230 volts ac input power, see Section 4-11.

1 Rating Label

Supply correct input power.

2Power Cord Connector

3Plug − NEMA Type 5-15P

4Receptacle − NEMA Type 5-15R (Customer Supplied)

5Plug − NEMA Type 5-20P (Optional)

6Receptacle NEMA Type 5-20R (Customer Supplied)

7Plug − NEMA Type 6-50P

8Receptacle − NEMA Type 6-50R (Customer Supplied)

Select plug for power supply receptacle available at site. Install plug onto power cord adapter. As threaded collar is tightened, push plug onto adapter until collar is completely tight.

Connect plug to receptacle.

9 Cylinder Support Bracket

Holes in the bracket provide a location to store the unused power cord plugs.

OM-1330 Page 18