Cabletron Systems SEH-24 EPIM-F1/F2, Parameter Typical Worst Worst Case Typical Value Budget

Page 23

INSTALLATION REQUIREMENTS/SPECIFICATIONS

2.3.2EPIM-F1/F2

The EPIM-F1 and EPIM-F2 shown in Figure 2-4 support Multimode Fiber Optic cabling. Each EPIM has an internal Cabletron Systems FOT-F™ Fiber Optic Transceiver. The EPIM-F1 is equipped with SMA Connectors and the EPIM-F2 is equipped with ST Connectors. Specifications for the EPIMs are listed below.

 

Figure 2-4. EPIM-F1 and EPIM-F2

 

Parameter

Typical

Worst

Worst Case Typical

 

Value

Case

Budget

Budget

Receive

 

 

 

 

Sensitivity:

-30.5 dBm

-28.0 dBm

Peak Input

 

 

 

 

Power:

-7.6 dBm

-8.2 dBm

Transmitter Power

 

 

 

50/125 ∝m

 

 

 

 

fiber:

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

62.5/125 ∝m

 

 

 

 

fiber:

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

100/140 ∝m

 

 

 

 

fiber:

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

Error Rate:

Better than 10-10

 

 

Note: The transmitter power levels and receive sensitivity levels listed are Peak Power Levels after optical overshoot. A Peak Power Meter must be used to correctly compare the values given above to those measured on any particular port. If Power Levels are being measured with an Average Power Meter, then 3 dBm must be added to the measurement to correctly compare those measured values to the values listed (i.e. -30.5 dBm peak=-33.5 dBm average).

Page 2-11

Image 23
Contents 10BASE-T Stackable HUB USER’S Guide Printed On Recycled Paper DOC Notice FCC NoticeCabletron Software Program License Cabletron SYSTEMS, INC Program License AgreementUnited States Government Restricted Rights Exclusion of Warranty Disclaimer of LiabilityTable of Contents Appendix B Twisted Pair Wiring Tables A-1 Contents InstallationConnecting to the Network TroubleshootingChapter Introduction Using this ManualSEH Overview Introduction Getting HelpPolarity Detection and Correction SEH FeaturesRepeater Functionality Epim Optional FeaturesStackable Capabilities Rack Mount or Wall Mount Hardware Daughter Board Upgrade KitHubSTACK Interconnect Cables Part Description Application NumberHubSTACK Interconnect Cable Requirements Cable SpecificationsJitter LengthInsertion Loss ImpedanceNoise DelayTemperature CrosstalkCable Type Attenuation Maximum Cable Length Fiber Optic Budget and Propagation DelayInstallation REQUIREMENTS/SPECIFICATIONS Terminators ConnectorsThin-net Network Requirements for the EPIM-C Module Cable TypeAUI Cable Network Port SpecificationsAUI Cable Requirements for the EPIM-A and EPIM-X Modules SEH-32 and SEH-34 Network Port Specifications SEH-22 and SEH-24 Network Port SpecificationsPin Champ Connector EPIM-T Installation REQUIREMENTS/SPECIFICATIONS Epim SpecificationsParameter Typical Worst Worst Case Typical Value Budget EPIM-F1/F2EPIM-F3 EPIM-F3Parameter Typical Minimum Maximum EPIM-C Connector TypeEPIM-A and EPIM-X EPIM-A and EPIM-X AUI PortGeneral Operating SpecificationsDelay Times Start of Packets Delay Times JAMJAM Output Fault ProtectionPower Supply Requirements Output Min. Load Max. Load Max PowerPhysical SafetyUnpacking the SEH Installing the SEHStacking the SEH SEH-2410BASE-T HUB with Lanview Disconnect SEH and Sehi Interconnect Cables At the OUT Port Attaching the Strain Relief BracketRack Mounting the SEH Installing the SEH in the RackWall Mounting the SEH Shelf or Table-top Installation Free-Standing InstallationInstallation Connecting the SEH to the Power Source Connecting Network Ports SEH-22 and SEH-24 Connecting the SEH to the NetworkEPIM-2 Connecting Network Ports SEH-32 and SEH-34 EPIM-T Cross-over Switch Connecting a UTP Segment to an EPIM-TConnecting to the Network Connecting to the Network Connecting to the Network Connecting a Thin-Net Segment to an EPIM-C EPIM-C EPIM-A Connecting an AUI Cable to an EPIM-AConnecting an AUI Cable to an EPIM-X On Position Toward Back Epim OFF Position Toward Front Finishing the InstallationInstallation CHECK-OUT Chapter TroubleshootingUsing Lanview Mgmt Green Flashing PWR GreenLNK Green CLN RedRCV Yellow Flashing Twisted Pair Wiring Tables Appendix a Twisted Pair Wiring TablesA-2 A-3 A-4 Drop Device From Punch Down To RJ-45 Into Block Wallplate Office10BASE-T A-6 A-7 Champ Down Block If Required Ethernet Device SEH-32/34 Punch Wall PlateFigure A-1. Punch Down Block A-9 French Power Supply CordGerman Spanish