Cabletron Systems 6A000 manual No Lane server address is specified see note below

Page 38

%•F"›amV˜"m˜'h¤d"›F=˜/"2

˜˜,6˜3¦F•˜":1˜"m=˜/"2'

1.Enter the start LECS command to activate LANE server services on this switch.

SmartCell ZX # start lecs

NOTICE - 'LECS' ***** LECS started *****

SmartCell ZX #

2.Create an ELAN on your SmartCell 6A000 switch by executing the add elan command. The following is an example.

SmartCell ZX # add elan

 

ELANNumber(0) : 1

<1 is used instead of the default, (0)

ELANName(ELAN001): Marketing <ELAN is named Marketing instead of the default, (ELAN000)

ConnectMethod(SVC):

 

ELANType(802.3)

<The default (Ethernet) is used

Multipoint(YES) :

 

MTU(1516) :

 

Distribute(PROXY) :

 

SmartCell ZX #

 

3.Create a client for the switch on the ELAN. For example, enter

SmartCell ZX # add laneclient

ClientNumber(0) :1<One is used instead of the default, (0)

LanName(ELAN001) : Marketing < ELAN name is Marketing, not the default, (ELAN001)

ServerType(LECS) :

 

ServerAddress()

<No LANE server address is specified; see note below

IPAddress() : 90.1.1.1

< IP address and subnet mask are included only as examples

NetMask(255.0.0.0): 255.255.255.0

MTU(1516) :

SmartCell ZX #

Note The command add laneclient always prompts you with a subnet mask that is appropriate for the IP address. However, if necessary, you can change the subnet mask to correspond to the strategy employed within your networks.

Note When you create a client, it automatically finds the LECS address using ILMI.

As the local client joins the ELAN, the following messages are sent to the Event log:

NOTICE - 'ZLESSRV' LES Join 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4:

14:41:82:00

NOTICE - 'ZLESSRV' BUS Connect 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4:

14:41:82:00

Caution Never create an ELAN (or ELAN client) with the same subnet as the SmartCell 6A000 Ethernet port.

3-4 SmartCell 6A000 User Guide

Image 38
Contents SmartCell 6A000 User Guide Ii SmartCell 6A000 User Guide FCC Class a Notice Declaration of Conformity Addendum Safety Information Class 1 Laser Transceivers Fiber Optic Protective Caps Regulatory Compliance Summary Safety Revision History Table of Contents Specifications Acronyms Index Xii SmartCell 6A000 User Guide List of Figures List of Figures Xiv SmartCell 6A000 User Guide List of Tables List of Tables Xvi SmartCell 6A000 User Guide Introduction Introduction SmartCell 6A000 User Guide Inspecting the Switch Switch Installation and SetupUnpacking the Switch Check Accessory Carton Contents6A-IOM-29-4 Face Plate Number Physical Specification 6A-IOM-21-46A-IOM-22-4 6A-IOM-29-4-IRInstalling the Switch 1 DS3 and E3 I/O Module ConfigurationInstalling the Switch Configuring the Switch Switch Installation and SetupConfiguring the Switch 6A000 console and network connections Using the Console Console CommandsSmartCell ZX # show portconfig a1 Console Time-out Creating an AliasAmbiguous Commands Console HelpExterior Smartswitch ATM AdministratorSmartCell ZX # ? add laneclient Installation Steps MB RAMStarting SmartSwitch ATM Administrator the First Time User Name Access Level Default PasswordAccessing Online Help SmartSwitch ATM Administrator IP Over ATM and Lane Creating AN IP Over ATM VlanServer Is local Server Connection Established Creating AN Emulated LAN ATM Addressing for IP over ATMNo Lane server address is specified see note below Ilmi ATM Addressing for LAN Emulation ELANs Across Multiple SwitchesSwitch Clients Elan1 ›amV˜m˜h¤d›F=˜/2 ˜˜,6˜3F˜1˜m=˜/2 SmartCell 6A000 User Guide Path /backdir/config-1 Switch AdministrationBacking UP and Restoring Switch Configuration SmartCell ZX # show netprefix b2 ATM RoutingCreating an Iisp Route Iisp Routing Considerations AtmAddressIisp route across Pnni domain UNI Routes 200 Route MetricsCbr 750IP Routing # show PnnimetricsZX # show route Route NETEvents and Alarms Event CategoriesViewing Events and Alarms SmartCell ZX # set eventdisplayPVC Connections Deleting Events and AlarmsSmartCell ZX # set alarmdisplay SmartCell ZX # show trafficdescriptor Point-to-Point PVCsPoint-to-Multipoint PVCs 100Md1 #add trafficdescriptor Local Connecting to Local Switch Client Through a PVCNon-zero VPIs 10.1.1.0VCC Mask Index VPI Bits VPI Values VCI Bits VCI Values ZX # set vccmaskUse show portconfig to see the change to port A1 SmartCell ZX # set portconfig a1Traffic Management Traffic DescriptorsType Number Descriptor Characteristics SmartCell ZX# show trafficdescriptor5000 Call Admission Control Policy8000 ZX# add pvcUbr Min for CBR queue EFCI, EPD, and RM Thresholds QoS Queue Recommended SettingsSmartCell ZX # show switchtrafficcongestion Accessing the Boot Load Prompt Upgrading and Changing SoftwareBoot Load Commands Command Action ParametersFlash RAM Upgrading Boot Load SoftwareBoot Prom =df b =df p Upgrading Post Diagnostic Software=chpi Upgrading Switch Operating Software =df sUsing the Update Firmware Command 214.95.77.240Saving Core Dumps 204.95.77.240 Tftpboot/bobr/coreSet CoreDump command BobrError IP e0103288 PFP e04be080 R0pfp e04be040 R1sp e04be0c0 Troubleshooting Troubleshooting IP Over ATMTroubleshooting LAN Emulation Troubleshooting Pnni Links Troubleshooting CongestionDiagnosing Congestion Global CongestionPort Congestion Troubleshooting Congestion Appendix a Specifications FunctionSpecification Value EjectorTable A-3 Physical Specifications Protocol Standard UNIManagement Protocol Supported MIBs RJ-45 Pin RJ-45 Color DB-9 Pin DB-9 DescriptionTechnical Specifications Appendix B Agent Support MIB, SMI, MIB Files and Internet MIB HierarchyZeitNet Cabletron Proprietary MIBs MIB, SMI, MIB Files and Internet MIB HierarchyRelation Between Object Identifier and the Represented Value Zeitnet Cabletron Proprietary MIB Groups Supported protocolsSupported SMI Formats Name Object Identifier FunctionSmartCell 6A000 MIB Support MIB Exceptions Non-ConformanceManaging the Smartcell 6A000 Console Commands that Affect the AgentUpdate firmware Backup Restore Reboot Managing the SmartCell 6A000 Appendix C Technical Support FAX ServiceElectronic Services Telephone AssistanceRepair Services Hardware WarrantySoftware Warranty Appendix D Acronyms IsdnBootp DTE FCS Ilmi LES Netbeui PDU RMA SVC VBR/RT Acronyms Appendix D-12 SmartCell 6A000 User Guide Index NumericsElan Lane Snmp Lane VPI