,6˜3¦F•˜":1˜"m=˜/"2' | %•F"›amV˜"m˜'h¤d"›F=˜/"2˜˜ |
4.Enter the show client command to make certain that the client is operational.
SmartCell ZX # show client 1
LANE Client 1
============================================================================
Client State | : Operational |
Client Address | : 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4:14:41:81:00 |
LAN Name | : Marketing |
LECS Addr Source | : ILMI |
LECS Address | : 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4:14:41:80:01 |
LES Address | : 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4:14:41:82:02 |
LAN Type | : 802.3 |
MTU | : 1516 |
IP Address | : 90.1.1.1 |
IP NetMask | : 255.255.255.0 |
SmartCell ZX #
Note While creating an ELAN client for the switch is not absolutely necessary, it does provide management connectivity with the switch over its ATM ports (instead of the Ethernet port). See Chapter 4, “Switch Administration” for information about how to reach switches not directly connected to the Ethernet network.
5.Physically connect your end nodes and edge devices to the SmartCell 6A000 ports.
6.Configure the ATM interface or adapter for all end nodes and edge devices. Typically, configuration consists of specifying LAN Emulation as the protocol, assigning the device an IP address that corresponds to the subnet of the switch’s client, and indicating that you want the device to either acquire the LECS address through ILMI or use the Well Known Address as the address for the LECS. For details on the SmartCell 6A000 automatic addressing scheme for LANE, see Section 3.2.1.
7.As each end device registers with the LES and BUS, messages are sent to the event log of the SmartCell 6A000 containing the LECS. You can check connectivity by pinging between end nodes.
Note If configured devices fail to join the ELAN, see Chapter 4, Section 4.2.2, “UNI
Routes.” Also, see Chapter 5, Section 5.2, “Troubleshooting LAN Emulation.”
Your ELAN is now operational. Additional ELANs can be created in the same way. See Chapter 4, “Switch Administration,” for information about SmartCell 6A000 switch operations and maintenance.
Note While it is possible for a single ELAN on the SmartCell 6A000 switch to support multiple subnets, in general, switch performance is best (and management easiest) when the
SmartCell 6A000 User Guide