Cabletron Systems 6A000 manual Min for CBR queue

Page 63

Switch Administration

TrafficManagement

For example, enter the show porttrafficcongestion command to view current buffer utilization.

SmartCell ZX # show porttrafficcongestion

 

 

 

PortNumber(ALL)

 

 

 

 

:

 

 

Port ID

Queue 1

Queue 2

Queue 3

Queue 4

 

Min

Max

Min

Max

Min

Max

Min

Max

============================================================================

A1

20

1000

20

2000

20

1000

20

16384

A2

20

1000

20

2000

20

1000

20

16384

A3

20

1000

20

2000

20

1000

20

16384

A4

20

1000

20

2000

20

1000

20

16384

B1

20

1000

20

2000

20

1000

20

16384

B2

20

1000

20

2000

20

1000

20

16384

B3

20

1000

20

2000

20

1000

20

16384

B4(CPU)

20

1000

20

2000

20

1000

20

16384

C1

20

1000

20

2000

20

1000

20

16384

C2

20

1000

20

2000

20

1000

20

16384

C3

20

1000

20

2000

20

1000

20

16384

C4

20

1000

20

2000

20

1000

20

16384

D1

20

1000

20

2000

20

1000

20

16384

D2

20

1000

20

2000

20

1000

20

16384

D3

20

1000

20

2000

20

1000

20

16384

D4

20

1000

20

2000

20

1000

20

16384

SmartCell ZX #

 

 

 

 

 

 

 

 

Min and Max are thresholds set on a per-queue, per-port basis and are measured in cells (53 bytes). The Min threshold is the amount of buffer space guaranteed to a call of a particular QoS on the corresponding port. The Max threshold is the maximum amount of buffer space that a call of a particular QoS is allowed on the corresponding port.

QoS corresponds to the queues as follows:

Queue 1 — Constant Bit Rate (CBR)

Queue 2 — Real Time Variable Bit Rate (rt-VBR)

Queue 3 — Non-real time Variable Bit Rate (Nrt-VBR)

Queue 4 — Unspecified Bit Rate (UBR)

If calls of a particular QoS type are being dropped on a particular port, use the set porttrafficcongestion command to raise the port’s queue Min threshold.

For example, to change both the Min and Max amounts of buffer space used for CBR calls on port a3, enter the following:

SmartCell ZX # set porttrafficcongestion

 

Port(ALL)

: a3

Queue1MinimumCellCounter(20)

: 1000 < Min for CBR queue

Queue2MinimumCellCounter(20)

:

Queue3MinimumCellCounter(20)

:

Queue4MinimumCellCounter(20)

:

Queue1MaximumCellCounter(1000)

: 10000 < Max for CBR queue

Queue2MaximumCellCounter(2000)

:

Queue3MaximumCellCounter(1000)

:

Queue4MaximumCellCounter(16384)

:

SmartCell ZX #

 

SmartCell 6A000 User Guide 4-21

Image 63
Contents SmartCell 6A000 User Guide Ii SmartCell 6A000 User Guide FCC Class a Notice Declaration of Conformity Addendum Safety Information Class 1 Laser Transceivers Fiber Optic Protective Caps Regulatory Compliance Summary Safety Revision History Table of Contents Specifications Acronyms Index Xii SmartCell 6A000 User Guide List of Figures List of Figures Xiv SmartCell 6A000 User Guide List of Tables List of Tables Xvi SmartCell 6A000 User Guide Introduction Introduction SmartCell 6A000 User Guide Check Accessory Carton Contents Switch Installation and SetupUnpacking the Switch Inspecting the Switch6A-IOM-29-4-IR Face Plate Number Physical Specification 6A-IOM-21-46A-IOM-22-4 6A-IOM-29-41 DS3 and E3 I/O Module Configuration Installing the SwitchInstalling the Switch Switch Installation and Setup Configuring the SwitchConfiguring the Switch 6A000 console and network connections Console Commands Using the ConsoleSmartCell ZX # show portconfig a1 Creating an Alias Console Time-outConsole Help Ambiguous CommandsSmartswitch ATM Administrator SmartCell ZX # ? add laneclientExterior MB RAM Installation StepsUser Name Access Level Default Password Starting SmartSwitch ATM Administrator the First TimeAccessing Online Help SmartSwitch ATM Administrator Creating AN IP Over ATM Vlan IP Over ATM and LaneServer Is local Server Connection Established ATM Addressing for IP over ATM Creating AN Emulated LANNo Lane server address is specified see note below Ilmi ELANs Across Multiple Switches Switch ClientsATM Addressing for LAN Emulation Elan1 ›amV˜m˜h¤d›F=˜/2 ˜˜,6˜3F˜1˜m=˜/2 SmartCell 6A000 User Guide Switch Administration Backing UP and Restoring Switch ConfigurationPath /backdir/config-1 ATM Routing Creating an Iisp RouteSmartCell ZX # show netprefix b2 AtmAddress Iisp Routing ConsiderationsIisp route across Pnni domain UNI Routes 750 Route MetricsCbr 200# show Pnnimetrics IP RoutingRoute NET ZX # show routeEvent Categories Events and AlarmsSmartCell ZX # set eventdisplay Viewing Events and AlarmsDeleting Events and Alarms SmartCell ZX # set alarmdisplayPVC Connections 100 Point-to-Point PVCsPoint-to-Multipoint PVCs SmartCell ZX # show trafficdescriptorMd1 #add trafficdescriptor 10.1.1.0 Connecting to Local Switch Client Through a PVCNon-zero VPIs LocalZX # set vccmask VCC Mask Index VPI Bits VPI Values VCI Bits VCI ValuesSmartCell ZX # set portconfig a1 Use show portconfig to see the change to port A1Traffic Descriptors Traffic ManagementSmartCell ZX# show trafficdescriptor Type Number Descriptor CharacteristicsZX# add pvc Call Admission Control Policy8000 5000Ubr Min for CBR queue QoS Queue Recommended Settings SmartCell ZX # show switchtrafficcongestionEFCI, EPD, and RM Thresholds Upgrading and Changing Software Accessing the Boot Load PromptCommand Action Parameters Boot Load CommandsUpgrading Boot Load Software Boot PromFlash RAM =df b Upgrading Post Diagnostic Software =chpi=df p =df s Upgrading Switch Operating Software214.95.77.240 Using the Update Firmware CommandSaving Core Dumps Bobr Tftpboot/bobr/coreSet CoreDump command 204.95.77.240Error IP e0103288 PFP e04be080 R0pfp e04be040 R1sp e04be0c0 Troubleshooting IP Over ATM TroubleshootingTroubleshooting LAN Emulation Troubleshooting Congestion Troubleshooting Pnni LinksGlobal Congestion Diagnosing CongestionPort Congestion Troubleshooting Congestion Function Appendix a SpecificationsEjector Specification ValueTable A-3 Physical Specifications UNI Protocol StandardRJ-45 Pin RJ-45 Color DB-9 Pin DB-9 Description Management Protocol Supported MIBsTechnical Specifications MIB, SMI, MIB Files and Internet MIB Hierarchy Appendix B Agent SupportMIB, SMI, MIB Files and Internet MIB Hierarchy ZeitNet Cabletron Proprietary MIBsRelation Between Object Identifier and the Represented Value Name Object Identifier Function Supported protocolsSupported SMI Formats Zeitnet Cabletron Proprietary MIB GroupsSmartCell 6A000 MIB Support Non-Conformance MIB ExceptionsConsole Commands that Affect the Agent Update firmware Backup Restore RebootManaging the Smartcell 6A000 Managing the SmartCell 6A000 Telephone Assistance FAX ServiceElectronic Services Appendix C Technical SupportHardware Warranty Software WarrantyRepair Services Isdn Appendix D AcronymsBootp DTE FCS Ilmi LES Netbeui PDU RMA SVC VBR/RT Acronyms Appendix D-12 SmartCell 6A000 User Guide Numerics IndexElan Lane Snmp Lane VPI