Cabletron Systems 6A000 manual Table of Contents

Page 9

TABLE OF CONTENTS

1

Introduction

1-1

2

Switch Installation and Setup

2-1

2.1

Unpacking the Switch

. 2-1

2.1.1

Check Accessory Carton Contents

. 2-1

2.2

Inspecting the Switch

. 2-1

2.2.1

DS3 and E3 I/O Module Configuration

. 2-3

2.3

Installing the Switch

. 2-3

2.4

Configuring the Switch

. 2-5

2.5

Using the Console

. 2-8

2.5.1

Console Commands

. 2-8

2.5.2

Console Time-out

2-10

2.5.3

Creating an Alias

2-10

2.5.4

Ambiguous Commands

2-11

2.5.5

Console Help

2-11

2.6

SmartSwitch ATM Administrator

2-12

2.6.1

Installation Steps

2-13

2.6.2

Starting SmartSwitch ATM Administrator the First Time

2-14

2.6.3

Accessing Online Help

2-15

3

IP Over ATM and LANE

3-1

3.1

Creating an IP over ATM VLAN

. 3-1

3.1.1

ATM Addressing for IP over ATM

. 3-3

3.2

Creating an Emulated LAN

. 3-3

3.2.1

ATM Addressing for LAN Emulation

. 3-6

3.2.2

ELANs Across Multiple Switches

. 3-6

3.2.3

Switch Clients

. 3-6

4

Switch Administration

4-1

4.1

Backing Up and Restoring Switch Configuration

. 4-1

4.2

ATM Routing

. 4-2

4.2.1

Creating an IISP Route

. 4-2

4.2.2

UNI Routes

. 4-5

4.2.3

Route Metrics

. 4-6

4.3

IP Routing

. 4-7

4.4

Events and Alarms

. 4-9

4.4.1

Event Categories

. 4-9

4.4.2

Viewing Events and Alarms

4-10

4.4.3

Deleting Events and Alarms

4-11

SmartCell 6A000 User Guide ix

Image 9
Contents SmartCell 6A000 User Guide Ii SmartCell 6A000 User Guide FCC Class a Notice Declaration of Conformity Addendum Safety Information Class 1 Laser Transceivers Fiber Optic Protective Caps Regulatory Compliance Summary Safety Revision History Table of Contents Specifications Acronyms Index Xii SmartCell 6A000 User Guide List of Figures List of Figures Xiv SmartCell 6A000 User Guide List of Tables List of Tables Xvi SmartCell 6A000 User Guide Introduction Introduction SmartCell 6A000 User Guide Unpacking the Switch Switch Installation and SetupInspecting the Switch Check Accessory Carton Contents6A-IOM-22-4 Face Plate Number Physical Specification 6A-IOM-21-46A-IOM-29-4 6A-IOM-29-4-IR1 DS3 and E3 I/O Module Configuration Installing the SwitchInstalling the Switch Switch Installation and Setup Configuring the SwitchConfiguring the Switch 6A000 console and network connections Console Commands Using the ConsoleSmartCell ZX # show portconfig a1 Creating an Alias Console Time-outConsole Help Ambiguous CommandsSmartswitch ATM Administrator SmartCell ZX # ? add laneclientExterior MB RAM Installation StepsUser Name Access Level Default Password Starting SmartSwitch ATM Administrator the First TimeAccessing Online Help SmartSwitch ATM Administrator Creating AN IP Over ATM Vlan IP Over ATM and LaneServer Is local Server Connection Established ATM Addressing for IP over ATM Creating AN Emulated LANNo Lane server address is specified see note below Ilmi ELANs Across Multiple Switches Switch ClientsATM Addressing for LAN Emulation Elan1 ›amV˜m˜h¤d›F=˜/2 ˜˜,6˜3F˜1˜m=˜/2 SmartCell 6A000 User Guide Switch Administration Backing UP and Restoring Switch ConfigurationPath /backdir/config-1 ATM Routing Creating an Iisp RouteSmartCell ZX # show netprefix b2 AtmAddress Iisp Routing ConsiderationsIisp route across Pnni domain UNI Routes Cbr Route Metrics200 750# show Pnnimetrics IP RoutingRoute NET ZX # show routeEvent Categories Events and AlarmsSmartCell ZX # set eventdisplay Viewing Events and AlarmsDeleting Events and Alarms SmartCell ZX # set alarmdisplayPVC Connections Point-to-Multipoint PVCs Point-to-Point PVCsSmartCell ZX # show trafficdescriptor 100Md1 #add trafficdescriptor Non-zero VPIs Connecting to Local Switch Client Through a PVCLocal 10.1.1.0ZX # set vccmask VCC Mask Index VPI Bits VPI Values VCI Bits VCI ValuesSmartCell ZX # set portconfig a1 Use show portconfig to see the change to port A1Traffic Descriptors Traffic ManagementSmartCell ZX# show trafficdescriptor Type Number Descriptor Characteristics8000 Call Admission Control Policy5000 ZX# add pvcUbr Min for CBR queue QoS Queue Recommended Settings SmartCell ZX # show switchtrafficcongestionEFCI, EPD, and RM Thresholds Upgrading and Changing Software Accessing the Boot Load PromptCommand Action Parameters Boot Load CommandsUpgrading Boot Load Software Boot PromFlash RAM =df b Upgrading Post Diagnostic Software =chpi=df p =df s Upgrading Switch Operating Software214.95.77.240 Using the Update Firmware CommandSaving Core Dumps Set CoreDump command Tftpboot/bobr/core204.95.77.240 BobrError IP e0103288 PFP e04be080 R0pfp e04be040 R1sp e04be0c0 Troubleshooting IP Over ATM TroubleshootingTroubleshooting LAN Emulation Troubleshooting Congestion Troubleshooting Pnni LinksGlobal Congestion Diagnosing CongestionPort Congestion Troubleshooting Congestion Function Appendix a SpecificationsEjector Specification ValueTable A-3 Physical Specifications UNI Protocol StandardRJ-45 Pin RJ-45 Color DB-9 Pin DB-9 Description Management Protocol Supported MIBsTechnical Specifications MIB, SMI, MIB Files and Internet MIB Hierarchy Appendix B Agent SupportMIB, SMI, MIB Files and Internet MIB Hierarchy ZeitNet Cabletron Proprietary MIBsRelation Between Object Identifier and the Represented Value Supported SMI Formats Supported protocolsZeitnet Cabletron Proprietary MIB Groups Name Object Identifier FunctionSmartCell 6A000 MIB Support Non-Conformance MIB ExceptionsConsole Commands that Affect the Agent Update firmware Backup Restore RebootManaging the Smartcell 6A000 Managing the SmartCell 6A000 Electronic Services FAX ServiceAppendix C Technical Support Telephone AssistanceHardware Warranty Software WarrantyRepair Services Isdn Appendix D AcronymsBootp DTE FCS Ilmi LES Netbeui PDU RMA SVC VBR/RT Acronyms Appendix D-12 SmartCell 6A000 User Guide Numerics IndexElan Lane Snmp Lane VPI