APPENDIX B
MEDIA SPECIFICATIONS AND REQUIREMENTS
This Appendix provides information about cabling media (Fiber, STP, UTP) used with the
B.1 FIBER OPTIC
Table
Table B-1. Signal Tolerances for Fiber Optic Cable
| Total | Maximum | |
Cable Type | Allowable | ||
Drive Distance | |||
| Attenuation | ||
|
| ||
|
|
| |
Multimode |
|
| |
|
|
| |
|
|
| |
50/125 ∝m | 13.0 dB or less | 2 km (2187.2 yards) | |
|
|
| |
62.5/125 ∝m | 16.0 dB or less |
| |
|
|
| |
100/140 ∝m | 19.0 dB or less |
| |
|
|
| |
Typical Signal Attenuation Rate: ≤ 2.5 dB/km. | |||
|
|
| |
|
| ||
|
|
| |
|
|
| |
10.0 dB or less | 10 km (10936.0 yards). | ||
|
|
|
Typical Signal Attenuation Rate: ≤ 0.5 dB/km.