Cabletron Systems BRIM-T6 manual Appendix B Media Specifications and Requirements, Fiber Optic

Page 33

APPENDIX B

MEDIA SPECIFICATIONS AND REQUIREMENTS

This Appendix provides information about cabling media (Fiber, STP, UTP) used with the BRIM-T6.

B.1 FIBER OPTIC

Table B-1 defines total signal attenuation tolerances for both single-mode and multimode fiber cabling. Both types of cabling have a typical constant attenuation rate per km of fiber cable, and each connector on the cable system contributes significant additional attenuation. Maximum drive distances define maximum allowable cable length.

Table B-1. Signal Tolerances for Fiber Optic Cable

 

Total

Maximum

Cable Type

Allowable

Drive Distance

 

Attenuation

 

 

 

 

 

Multimode

 

 

 

 

 

 

 

 

50/125 m

13.0 dB or less

2 km (2187.2 yards)

 

 

 

62.5/125 m

16.0 dB or less

 

 

 

 

100/140 m

19.0 dB or less

 

 

 

 

Typical Signal Attenuation Rate: 2.5 dB/km.

 

 

 

Single-Mode

 

 

 

 

 

 

 

 

8/125-12/125 m

10.0 dB or less

10 km (10936.0 yards).

 

 

 

Typical Signal Attenuation Rate: 0.5 dB/km.

NOTE: The attenuation values shown include the attenuation attributable to cables, connectors, patch panels, and reflection losses due to impedance mismatches in the segment.

B-1

Image 33
Contents BRIM-T6 USER’S Guide Page All Rights Reserved Order Number 9031288 September FCC Notice DOC NoticeVcci Notice Cabletron Software Program License Program License AgreementUnited States Government Restricted Rights Exclusion of Warranty & Disclaimer LiabilityContents Appendix B Media Specifications and Requirements Chapter Introduction Using this ManualMedia Flexibility Introducing the BRIM-T6Bridge/Routing Protocols Jumper Selectable Ring SpeedSpanning Tree Algorithm STA Compliance BRIM-T6 ManagementSafety Brim SpecificationsRelated Documentation EnvironmentNetworking Publications Getting HelpIntroduction Chapter Installation Installing the BRIM-T6Unpacking the BRIM-T6 Installing the BRIM-T6 into a MIM Installing the BRIM-T6 Configuring the BRIM-T6 Ring Speed Installing the BRIM-T6 into a Standalone DeviceSPD Configuring and Installing TPIMs Tpim Configuration for Station Applications Installing TPIMs Connecting STP Segments Chapter Connecting to the NetworkConnecting Fiber Optic Segments Connecting UTP SegmentsConnecting Fiber Optic Segments Connecting to the Network Chapter Monitoring and Troubleshooting Lanview Leds16Mb Ring Speed RCV Receive XMT TransmitSTB Standby LNK Media Link OK on attached TpimLED Specifications Summary Checking the ConnectionMonitoring and Troubleshooting Appendix a Tpim Specifications Twisted Pair Tpim Pinouts Station ModeFiber Optic Tpim Specifications Tpim Specifications Fiber Optic Appendix B Media Specifications and RequirementsImpedance and Attentuation Shielded Twisted Pair STPUnshielded Twisted Pair UTP Maximum Lobe LengthMaximum Trunk Lengths Table B-4. UTP Voice Grade and Category 3 Specifications Attenuation and ImpedanceMaximum Lobe Lengths Media Specifications and Requirements