EMC DS-16B2 Displaying the Temperature Status, Running Diagnostic Tests on the Switch Hardware

Page 38

3

Displaying Error Logs and Status

Displaying the Temperature Status

To display the temperature status of a switch:

1.Login to the switch as the admin user.

2.At the command line enter the following command: tempShow

This command displays current temperature readings from each of the five temperature sensors located on the main printed circuit board of the switch. The sensors are located, approximately, one in each corner and one at the center of the PCB.

Running Diagnostic Tests on the Switch Hardware

There are several diagnostic tests you can run on a switch. These tests are generally run during the POST, each time a switch is booted up.

camtest

centralMemoryTest

cmemRetentionTest

cmiTest

crossPortTest

portLoopbackTest

sramRetentionTest

turboRamTest

statsTest

spinSilk

supportShow

The supportShow command is used to gather switch information for debugging purposes. Your EMC Customer Service representative may ask you to run this command and capture the output. This information will aid Customer Service in diagnosing problems that could occur on the switch.

3-8

Departmental Switch Model DS-16B2 Fabric OS Procedures Manual

 

 

Image 38
Contents Departmental Switch Model DS-16B2 Fabric OS Procedures ManualCopyright 2001 EMC Corporation. All rights reserved Trademark Information Departmental Switch DS-16B2 Fabric OS Procedures Manual Contents Chapter Displaying Error Logs and Status Preface Damage to the system or equipment. The caution may apply to Palatino Http//powerlink.emc.com Setting the Initial Switch Configuration Logging In to a Switch Switch55adminEnabling Licensed Features Displaying the Installed Feature Licenses Changing the Admin Password and User IDConfiguring the IP Address Displaying the Fabric-Wide Device Count Basic Switch Configuration Procedures Setting the Telnet Timeout Value Displaying the Firmware VersionSetting the Switch Date and Time Displaying the System Configuration Settings Backing Up the System Configuration SettingsRestoring the System Configuration Settings Upgrading or Restoring the Switch Firmware Disabling a SwitchEnabling a Port Enabling a SwitchDisabling a Port Changing a Switch Name Setting the Switch Status Policy Viewing the Policy Threshold ValuesEnabling the Track Changes Feature Displaying Whether Track Changes is EnabledConfiguring a Static Route Between Two Ports Displaying Help Information for a Telnet CommandReading Hexadecimal Port Diagrams Example0000 0001 0010 1000 0011 Departmental Switch DS-16B2 Fabric OS Procedures Manual Displaying Error Logs Status Displaying the Status of a Port Statistics for a PortDisplaying a Summary of Port Errors Error Type DescriptionDisplaying the Error Log of a Switch Displaying the Switch StatusDisplaying Information About a Switch Displaying the Uptime of the Switch Displaying the Fan StatusDisplaying Power Supply Status SupportShow Displaying the Temperature StatusRunning Diagnostic Tests on the Switch Hardware Syntax supportShow firstPort, lastPort, nLog Displaying Error Logs and Status Customer Support Overview of Detecting and Resolving Problems Figure A-1Problem Detection and Resolution ProcessTroubleshooting the Problem Before Calling the Customer Support Center Documenting the Problem Reporting a New Problem Sending Problem Documentation FTPCustomer Support Glossary Glossary Glossary Configuration EIA Rack Glossary Glossary Glossary See also Nonparticipating Mode and Participating Mode Glossary Glossary Glossary Glossary Glossary UDP Glossary