EMC DS-16B2 manual Glossary

Page 61

Glossary

RAID Redundant Array of Independent Disks; a collection of disk drives that appear as a single volume to the server and are fault tolerant through mirroring or parity checking. See also JBOD.

Request Rate The rate at which requests arrive at a servicing entity. See also Service Rate.

Route As applies to a fabric, the communication path between two switches. May also apply to the specific path taken by an individual frame, from source to destination. See also FSPF.

Routing The assignment of frames to specific switch ports, according to frame destination.

RR_TOV Resource Recovery Time out Value; the minimum time a target device in a loop waits after a LIP before logging out a SCSI initiator. See also E_D_TOV, R_A_TOV.

RSCN Registered State Change Notification; a switch function that allows notification of fabric changes to be sent from the switch to specified nodes.

S

SAN Storage Area Network; a network of systems and storage devices that

communicate using Fibre Channel protocols. See also Fabric.

Sequence A group of related frames transmitted in the same direction between two N_Ports.

Service Rate The rate at which an entity can service requests. See also Request Rate.

SES A Brocade product that runs on Fabric OS and allows monitoring, configuring, and maintenance of the Departmental Switch family using SCSI 3 Enclosure Services.

SFP Small Form Factor Pluggable; optical transceiver used to convert signals between optical fiber cables and switches.

SI Sequence Initiative.

Single Mode The fiber optic cabling standard that corresponds to distances of up to 10 km between devices.

Departmental Switch Model DS-16B2 Fabric OS Procedures Manual

g-13

Image 61
Contents Procedures Manual Departmental Switch Model DS-16B2 Fabric OSCopyright 2001 EMC Corporation. All rights reserved Trademark Information Departmental Switch DS-16B2 Fabric OS Procedures Manual Contents Chapter Displaying Error Logs and Status Preface Damage to the system or equipment. The caution may apply to Palatino Http//powerlink.emc.com Setting the Initial Switch Configuration Switch55admin Logging In to a SwitchEnabling Licensed Features Changing the Admin Password and User ID Displaying the Installed Feature LicensesConfiguring the IP Address Displaying the Fabric-Wide Device Count Basic Switch Configuration Procedures Displaying the Firmware Version Setting the Telnet Timeout ValueSetting the Switch Date and Time Backing Up the System Configuration Settings Displaying the System Configuration SettingsRestoring the System Configuration Settings Disabling a Switch Upgrading or Restoring the Switch FirmwareDisabling a Port Enabling a SwitchEnabling a Port Changing a Switch Name Viewing the Policy Threshold Values Setting the Switch Status PolicyDisplaying Whether Track Changes is Enabled Enabling the Track Changes FeatureDisplaying Help Information for a Telnet Command Configuring a Static Route Between Two PortsExample Reading Hexadecimal Port Diagrams0000 0001 0010 1000 0011 Departmental Switch DS-16B2 Fabric OS Procedures Manual Displaying Error Logs Status Statistics for a Port Displaying the Status of a PortError Type Description Displaying a Summary of Port ErrorsDisplaying the Switch Status Displaying the Error Log of a SwitchDisplaying Information About a Switch Displaying the Fan Status Displaying the Uptime of the SwitchDisplaying Power Supply Status Running Diagnostic Tests on the Switch Hardware Displaying the Temperature StatusSupportShow Syntax supportShow firstPort, lastPort, nLog Displaying Error Logs and Status Customer Support Figure A-1Problem Detection and Resolution Process Overview of Detecting and Resolving ProblemsTroubleshooting the Problem Before Calling the Customer Support Center Documenting the Problem Reporting a New Problem FTP Sending Problem DocumentationCustomer Support Glossary Glossary Glossary Configuration EIA Rack Glossary Glossary Glossary See also Nonparticipating Mode and Participating Mode Glossary Glossary Glossary Glossary Glossary UDP Glossary