Extron electronic IPL T S Series manual Furniture or projector mounting

Page 16

Installation and Operation, cont’d

IPLTS2

R

1TX 2

COM

 

RX

RTS

CTS

®

100 LINK ACT

IPLTS2

R

1TX 2

COM

 

RX

RTS

CTS

®

100 LINK ACT

MDA

DISTRIBUTIONSERIES

AMPLIFIER

Figure 2-2 — Mounting the interface on the standard shelf

Furniture or projector mounting

The following furniture and projector mount kits are available:

PN 70-077-01

Furniture mount kit (for IPL T S1)

PN 70-077-04

Projector mount kit (for IPL T S1)

PN 70-212-01

Furniture mount kit (for IPL T S2, S4, S6)

PN 70-217-04

Projector mount kit (for IPL T S2, S4, S6)

To mount an IPL T S Series device to furniture:

1.

If present, remove the rubber feet from the bottom of the IPL T S unit.

2.

Attach the furniture mounting brackets to the unit with the supplied screws.

3.

Hold the unit with the attached brackets against the underside of the

 

furniture. Mark the hole locations of the bracket on the mounting surface.

4.Drill 3/32” (2 mm) diameter pilot holes, 1/4” (6.3 mm) deep in the underside of the mounting surface at the marked hole locations.

5.

Insert #8 wood screws into the four pilot holes. Tighten each screw until just

 

less than 1/4” (6.3 mm) of the screw head protrudes above the surface.

6.

Hang the mounting bracket over the protruding screw heads. Slide the

 

mounting brackets to the narrow end of the screw slots and tighten the

 

mounting screws.

To mount an IPL T S Series device with a projector:

1.

If present, remove the rubber feet from the bottom of the IPL T S unit.

2.

Attach the projector mounting bracket to the unit with the supplied screws.

3.

Secure the unit to the projector post with the supplied mounting bolt.

2-4 IPL T S Series • Installation and Operation

Image 16
Contents IPL T S Series IP Link Ethernet Control InterfacesPrecautions Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschIPL T S Series FCC Class a NoticeIi IPL T S Series Quick Start IPL T S Series On a projectorUnder a desk Or on a rackQS-2 IPL T S Series Quick Start Table of Contents PreliminaryTable of Contents, cont’d One About This Manual IntroductionAbout the IPL T S Series Interface Features IPL T S6Introduction, cont’d Two Installation and Operation Installation OverviewIPL T S Series Installation and Operation Mounting the IPL T S InterfaceMounting options Rack mounting an IPL T S Series interfaceMounting Type Kit PN VersaTools 19 1U Rack ShelfFurniture or projector mounting Furniture mount kit for IPL T S1Projector mount kit for IPL T S1 Furniture mount kit for IPL T S2, S4, S6Rear Panel Features and Cabling Mounting the interfacePower PreliminarySerial Communication Ethernet/LANLink LED a lit green LED indicates a good LAN connection IPL T S Series Installation Pin Function RS-232 RS-422 RS-485Front panel indicators OperationIdentification UID # The unique user ID number MAC address of the unit forResetting the unit Unit later in this chapter for more informationRX LEDs a green LED indicates data is being received by LED is not lit, the connection speed is 10 MbpsReset Mode Comparison/Summary Mode Activation ResultInstallation and Operation, cont’d Three Connection and Configuration Connecting the HardwareIPL T S Series Connection and Configuration Ethernet connectionHold down the Reset button until the Power LED blinks twice Setting the Internet Protocol IP AddressRear panel of the unit ex 00-05-A6-01-0A-74 Setting the IP address using Global Configurator Add Device dialog box opens see figureEnter a unique device name in the Display Name field Advanced options of the Add Device dialog are displayed,Setting the IP address using embedded Web pages IP address Subnet mask Default gateway blankInternet Protocol TCP/IP Properties dialog box Start All Programs Accessories Command Prompt Setting the IP address using the ARP commandArp sIP addressMAC address Configuration using Global Configurator Click the Download GCSW2XX.exe buttonConfiguration using Embedded Web Pages Global ConfiguratorConnecting via the Web server pages Web server Password dialog boxConfiguration System SettingsIP Settings Date/Time Settings System Status12 System Settings screen Port SettingsPasswords Email AlertsFirmware Upgrade File ManagementConfiguration using DataViewer To download DataViewerScroll to the description of DataViewer To run DataViewer19 Communication Setup dialog box DataViewer application opens see figureFour Using the command/response table Communication and ControlProgrammer’s Guide for Telnet and Web Browsers IPL T S Series Communication and ControlSymbol definitions X1% = Domain name e.g., extron.com, icia.orgPassword information Copyright informationError responses E17 System timed out E22 BusyCommunication Bidirectional serial data portSeries Communication and Control Ascii to Decimal Conversion Table X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2 X2%, X2, X2&, X2  X!*X2CY CpnX!CtyX2X5,X5#,X2 X6 TCSeries Communication and Control Ethernet data portX1!  SeriesCommunication and Control Firmware version, part number and information requests X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&   X4%CRX4, X4&   X4%SM X4%,X7,X4&SM WX4%%2CX7%2CX4&SM  X1$ ,X1% ,X7# ,X7$ CMIpmX1$ ,X1% ,X7# ,X7$  X1& ,X1% CM WX1$ %2CX1% CM IpmX1$ ,X1% X1@CN X1@ X1#CT X1#X2@   X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$  X6$ EB  X6$,X1$ Password and security settings  X3# CA X3# CU WX3# CU X5@Remap port designations Directories Stream files via Telnet or RS-232 Subnet mask is reset to IP address is reset toDiscussed in Resetting the Unit This example the N command is used to request CustomizationCustom Web pages Server Side Includes SSIQuery string Href=index.html?cmd=xInput #1/aCode examples Example6b Browser view of previous Html source code URL encoding Reserved charactersAdvanced Serial Port Control Serial pass-through redirect modeUnsafe characters Direct port access ports 2001 through To initiate direct port access using DataViewerClick OK. The DataViewer commands window opens To end the direct access session, close DataViewerSerial Bridging Hardware connectionSerial bridge configuration IPL T S4Power connections TroubleshootingData connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories Specifications, Part Numbers, Accessories SpecificationsIPL T S Series Specifications, Part Numbers, Accessories Serial, 10-pole captive screwMounting Rack mount Or VersaTools 1U, 3.5 deep rack shelf RSF 123, #60-190-20Part Numbers and Accessories Optional accessoriesIncluded parts Replacement part Number Accessories Part numberAppendix B Glossary GlossaryIPL T S Series Glossary IPL T S Series Glossary Extron’s Warranty Extron Europe Extron AsiaExtron Japan Extron China