Extron electronic IPL T S Series manual X5,X5#,X2, X6 TC, Series Communication and Control

Page 48

4-8 IPL T

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to unit)

(host to unit)

(unit to host)

 

View pass-thru

E X!CD}

WX!CD

X5),X5#,X2!]

mode24

 

 

 

S Series • Communication and Control

Ethernet data port

Set current connection E0*X6(TC} port timeout

View current

E0TC}

connection port

 

timeout

 

Set global IP port

E1*X6(TC}

timeout

 

View global IP port

E1TC}

timeout

 

W0%2AX6(TC

Pti0*X6(]

The current port timeout period applies

 

 

to the currently open Telnet session only.

 

 

When you start another Telnet session, it

 

 

uses the default global port timeout period.

 

 

X6( = timeout period in seconds. See

 

 

the description above. This variable is

 

 

applicable only when the IPL T S unit is

 

 

connected via Ethernet. If the IPL T S device

 

 

is connected via RS-232 protocol, only the

 

 

global timeout commands apply, and any

 

 

commands involving X6( return the E13

 

 

error response.

W0TC

X6(]

 

W1%2A X6(TC

Pti1*X6(]

The global port timeout is the default

 

 

timeout period for all Telnet sessions.

 

 

X6( = IP connection timeout period

 

 

in seconds. Each step is specified

 

 

in 10-second intervals (1 - 65000,

 

 

default = 30 = 300 seconds). If no data is

 

 

received during the specified period, the

 

 

Ethernet connection closes. Responses are

 

 

returned with leading zeros.

 

 

This timeout period is applicable only

 

 

when the IPL T S unit is connected via

 

 

Ethernet, and you must be logged in as an

 

 

administrator to change this setting.

W1TC

X6(]

 

Communication and Control, cont’d

Image 48
Contents IPL T S Series IP Link Ethernet Control InterfacesPrecautions Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschIPL T S Series FCC Class a NoticeIi IPL T S Series Quick Start IPL T S Series On a projectorUnder a desk Or on a rackQS-2 IPL T S Series Quick Start Table of Contents PreliminaryTable of Contents, cont’d One Introduction About This ManualAbout the IPL T S Series Interface Features IPL T S6Introduction, cont’d Two Installation and Operation Installation OverviewIPL T S Series Installation and Operation Mounting the IPL T S InterfaceMounting options Rack mounting an IPL T S Series interfaceMounting Type Kit PN VersaTools 19 1U Rack ShelfFurniture or projector mounting Furniture mount kit for IPL T S1Projector mount kit for IPL T S1 Furniture mount kit for IPL T S2, S4, S6Rear Panel Features and Cabling Mounting the interfacePower PreliminaryEthernet/LAN Serial CommunicationLink LED a lit green LED indicates a good LAN connection IPL T S Series Installation Pin Function RS-232 RS-422 RS-485Front panel indicators OperationIdentification UID # The unique user ID number MAC address of the unit forResetting the unit Unit later in this chapter for more informationRX LEDs a green LED indicates data is being received by LED is not lit, the connection speed is 10 MbpsReset Mode Comparison/Summary Mode Activation ResultInstallation and Operation, cont’d Three Connection and Configuration Connecting the HardwareIPL T S Series Connection and Configuration Ethernet connectionSetting the Internet Protocol IP Address Hold down the Reset button until the Power LED blinks twiceRear panel of the unit ex 00-05-A6-01-0A-74 Setting the IP address using Global Configurator Add Device dialog box opens see figureEnter a unique device name in the Display Name field Advanced options of the Add Device dialog are displayed,Setting the IP address using embedded Web pages IP address Subnet mask Default gateway blankInternet Protocol TCP/IP Properties dialog box Setting the IP address using the ARP command Start All Programs Accessories Command PromptArp sIP addressMAC address Configuration using Global Configurator Click the Download GCSW2XX.exe buttonConfiguration using Embedded Web Pages Global ConfiguratorConnecting via the Web server pages Web server Password dialog boxConfiguration System SettingsIP Settings Date/Time Settings System Status12 System Settings screen Port SettingsPasswords Email AlertsFirmware Upgrade File ManagementConfiguration using DataViewer To download DataViewerScroll to the description of DataViewer To run DataViewer19 Communication Setup dialog box DataViewer application opens see figureFour Using the command/response table Communication and ControlProgrammer’s Guide for Telnet and Web Browsers IPL T S Series Communication and ControlSymbol definitions X1% = Domain name e.g., extron.com, icia.orgPassword information Copyright information Error responses E17 System timed out E22 BusyCommunication Bidirectional serial data portSeries Communication and Control Ascii to Decimal Conversion Table X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2 X2%, X2, X2&, X2  X!*X2CY CpnX!CtyX2X5,X5#,X2 X6 TCSeries Communication and Control Ethernet data portX1!  SeriesCommunication and Control Firmware version, part number and information requests X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&   X4%CRX4, X4&   X4%SM X4%,X7,X4&SM WX4%%2CX7%2CX4&SM  X1$ ,X1% ,X7# ,X7$ CMIpmX1$ ,X1% ,X7# ,X7$  X1& ,X1% CM WX1$ %2CX1% CM IpmX1$ ,X1% X1@CN X1@ X1#CT X1#X2@   X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$  X6$ EB  X6$,X1$ Password and security settings  X3# CA X3# CU WX3# CU X5@Remap port designations Directories Stream files via Telnet or RS-232 IP address is reset to Subnet mask is reset toDiscussed in Resetting the Unit This example the N command is used to request CustomizationCustom Web pages Server Side Includes SSIQuery string Href=index.html?cmd=xInput #1/aCode examples Example6b Browser view of previous Html source code URL encoding Reserved charactersSerial pass-through redirect mode Advanced Serial Port ControlUnsafe characters Direct port access ports 2001 through To initiate direct port access using DataViewerClick OK. The DataViewer commands window opens To end the direct access session, close DataViewerSerial Bridging Hardware connectionSerial bridge configuration IPL T S4Troubleshooting Power connectionsData connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories Specifications, Part Numbers, Accessories SpecificationsIPL T S Series Specifications, Part Numbers, Accessories Serial, 10-pole captive screwMounting Rack mount Or VersaTools 1U, 3.5 deep rack shelf RSF 123, #60-190-20Part Numbers and Accessories Optional accessoriesIncluded parts Replacement part Number Accessories Part numberAppendix B Glossary GlossaryIPL T S Series Glossary IPL T S Series Glossary Extron’s Warranty Extron Europe Extron AsiaExtron Japan Extron China