Extron electronic IPL T S Series manual Communication Setup dialog box

Page 40

Connection and Configuration, cont’d

3. Enter the device’s IP address in the Hostname/IP Address field.

4. Click OK.

Figure 3-19 — Communication Setup dialog box

The DataViewer application opens (see figure 3-16).

See the DataViewer help file for information on sending commands to the IPL T S Series device, and viewing the responses in the DataViewer user interface.

3-16 IPL T S Series • Connection and Configuration

Image 40
Contents IPL T S Series IP Link Ethernet Control InterfacesPrecautions Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschIPL T S Series FCC Class a NoticeIi IPL T S Series Quick Start IPL T S Series On a projectorUnder a desk Or on a rackQS-2 IPL T S Series Quick Start Table of Contents PreliminaryTable of Contents, cont’d One About This Manual IntroductionAbout the IPL T S Series Interface Features IPL T S6Introduction, cont’d Two Installation and Operation Installation OverviewIPL T S Series Installation and Operation Mounting the IPL T S InterfaceMounting options Rack mounting an IPL T S Series interfaceMounting Type Kit PN VersaTools 19 1U Rack ShelfFurniture or projector mounting Furniture mount kit for IPL T S1Projector mount kit for IPL T S1 Furniture mount kit for IPL T S2, S4, S6Rear Panel Features and Cabling Mounting the interfacePower PreliminarySerial Communication Ethernet/LANLink LED a lit green LED indicates a good LAN connection IPL T S Series Installation Pin Function RS-232 RS-422 RS-485Front panel indicators OperationIdentification UID # The unique user ID number MAC address of the unit forResetting the unit Unit later in this chapter for more informationRX LEDs a green LED indicates data is being received by LED is not lit, the connection speed is 10 MbpsReset Mode Comparison/Summary Mode Activation ResultInstallation and Operation, cont’d Three Connection and Configuration Connecting the HardwareIPL T S Series Connection and Configuration Ethernet connectionHold down the Reset button until the Power LED blinks twice Setting the Internet Protocol IP AddressRear panel of the unit ex 00-05-A6-01-0A-74 Setting the IP address using Global Configurator Add Device dialog box opens see figureEnter a unique device name in the Display Name field Advanced options of the Add Device dialog are displayed,Setting the IP address using embedded Web pages IP address Subnet mask Default gateway blankInternet Protocol TCP/IP Properties dialog box Start All Programs Accessories Command Prompt Setting the IP address using the ARP commandArp sIP addressMAC address Configuration using Global Configurator Click the Download GCSW2XX.exe buttonConfiguration using Embedded Web Pages Global ConfiguratorConnecting via the Web server pages Web server Password dialog boxConfiguration System SettingsIP Settings Date/Time Settings System Status12 System Settings screen Port SettingsPasswords Email AlertsFirmware Upgrade File ManagementConfiguration using DataViewer To download DataViewerScroll to the description of DataViewer To run DataViewer19 Communication Setup dialog box DataViewer application opens see figureFour Using the command/response table Communication and ControlProgrammer’s Guide for Telnet and Web Browsers IPL T S Series Communication and ControlSymbol definitions X1% = Domain name e.g., extron.com, icia.orgPassword information Copyright informationError responses E17 System timed out E22 BusyCommunication Bidirectional serial data portSeries Communication and Control Ascii to Decimal Conversion Table X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2 X2%, X2, X2&, X2  X!*X2CY CpnX!CtyX2X5,X5#,X2 X6 TCSeries Communication and Control Ethernet data portX1!  SeriesCommunication and Control Firmware version, part number and information requests X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&   X4%CRX4, X4&   X4%SM X4%,X7,X4&SM WX4%%2CX7%2CX4&SM  X1$ ,X1% ,X7# ,X7$ CMIpmX1$ ,X1% ,X7# ,X7$  X1& ,X1% CM WX1$ %2CX1% CM IpmX1$ ,X1% X1@CN X1@ X1#CT X1#X2@   X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$  X6$ EB  X6$,X1$ Password and security settings  X3# CA X3# CU WX3# CU X5@Remap port designations Directories Stream files via Telnet or RS-232 Subnet mask is reset to IP address is reset toDiscussed in Resetting the Unit This example the N command is used to request CustomizationCustom Web pages Server Side Includes SSIQuery string Href=index.html?cmd=xInput #1/aCode examples Example6b Browser view of previous Html source code URL encoding Reserved charactersAdvanced Serial Port Control Serial pass-through redirect modeUnsafe characters Direct port access ports 2001 through To initiate direct port access using DataViewerClick OK. The DataViewer commands window opens To end the direct access session, close DataViewerSerial Bridging Hardware connectionSerial bridge configuration IPL T S4Power connections TroubleshootingData connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories Specifications, Part Numbers, Accessories SpecificationsIPL T S Series Specifications, Part Numbers, Accessories Serial, 10-pole captive screwMounting Rack mount Or VersaTools 1U, 3.5 deep rack shelf RSF 123, #60-190-20Part Numbers and Accessories Optional accessoriesIncluded parts Replacement part Number Accessories Part numberAppendix B Glossary GlossaryIPL T S Series Glossary IPL T S Series Glossary Extron’s Warranty Extron Europe Extron AsiaExtron Japan Extron China
Related manuals
Manual 29 pages 23.94 Kb

IPL T S Series specifications

The Extron IPL T SFI244 is a sophisticated control system that is designed to streamline the management and operation of audiovisual equipment in a variety of environments, including conference rooms, classrooms, and auditoriums. This model falls under the IPL T S Series, renowned for its superior performance and user-friendly interface, making it a popular choice for integrators and users alike.

One of the standout features of the IPL T SFI244 is its advanced interface. It boasts an intuitive touch panel that enables users to manage multiple devices from a single control point, significantly simplifying the AV experience. The system supports a wide range of functions, including source selection, volume control, and the management of lighting and screen mechanisms. This centralized control helps to enhance collaboration and communication, particularly in educational and corporate settings.

The IPL T SFI244 integrates seamlessly with a variety of Extron technologies, including the GlobalViewer Enterprise, providing real-time monitoring and management capabilities. This web-based software solution gives administrators the ability to control AV systems remotely, ensuring optimal performance and minimizing downtime.

Another key characteristic of the IPL T SFI244 is its versatility. It incorporates various input and output options, such as HDMI, VGA, and audio connections, to accommodate different audiovisual equipment. This flexibility allows for easy integration into existing setups, catering to diverse applications and user preferences.

In terms of design, the IPL T SFI244 is engineered with reliability and durability in mind. It is equipped with features that enhance its performance in professional environments, including programmable button layouts that can be customized by users. This personalization ensures that the control system meets specific operational requirements, further enhancing the user experience.

Furthermore, the IPL T SFI244 is built with energy efficiency in mind, utilizing technologies that reduce power consumption without compromising performance. This eco-friendly approach not only supports sustainability initiatives but also contributes to long-term cost savings for organizations.

In summary, the Extron IPL T SFI244 is a comprehensive control solution that combines advanced technology, user-friendly features, and robust performance. Its ability to integrate with various AV equipment, coupled with its customizable interface and reliability, makes it an excellent choice for a wide range of applications, paving the way for more efficient and effective audiovisual management.