Extron electronic IPL T S Series manual Symbol definitions

Page 43

Symbol definitions

] = CR/LF (carriage return/line feed)

}= Carriage return (no line feed)

= Space character

X! = Specific port number (01-99)

The port number is represented as two ASCII characters (2 bytes). For example, port 05 would be represented as 30 35 in hex.

X@ = Command data section

X@ is the command string for sending data to an A/V product (e.g., a switcher or projector) attached to an IPL T S unit. For remote processing examples, see “Customization” later in this chapter.

NSee "URL Encoding” for command restrictions.

X# = Greenwich Mean Time (GMT) offset value (-12.0 to +14.0) X% = On/Off status: 0 = Off/Disable; 1 = On/Enable

X1! = Unit version number

X1@ = Name is a text string up to 24 characters drawn from the alphabet (A-Z), digits (0-9), minus sign/

hyphen (-). No blank or space characters are permitted as part of a name. No distinction is made between upper and lower case. The first character must be an alpha character. The last character must not be a minus sign/hyphen.

X1# = Set local date and time format (MM/DD/YY-HH:MM:SS) (e.g., 02/01/06-10:54:00)

Read local date and time format (day of week, date month year HH:MM:SS) (e.g., Tues, 14 Feb 2006 18:19:33)

X1$ = IP address (xxx.xxx.xxx.xxx). Leading zeros in each of four fields are optional in setting values,

and are suppressed in returned values.

X1% = Domain name (e.g., extron.com, icia.org)

X1& = Time in tens of milliseconds to wait for characters coming into a serial port before terminating

(default=1=10 ms, max.=32767)

X1* = Hardware (MAC) address (xx-xx-xx-xx-xx-xx)

X1( = Subnet mask (xxx.xxx.xxx.xxx). Leading zeros in each of four fields are optional in setting

values, and are suppressed in returned values.

X2) = Time in tens of milliseconds to wait between characters coming into a serial port before terminating

(default=2=20 ms, max.=32767)

X2! = Parameter to set either Length of message to receive or Delimiter value. If length delimited, use xxL, where xx is the length of the incoming message in bytes. If character delimited, use xxD, where xx is the decimal ASCII value of the delimiting character.

X2@ = Verbose/response Mode: 0=clear/none; 1=verbose mode; 2=tagged responses for queries; 3=verbose mode and tagged responses for queries. (Default = 0 for Telnet connections, 1

for RS-232 host control).

NIf tagged responses is enabled, all read commands return the constant string + the data, as setting the value does. For example, Command: Esc CN }

Response: Ipn • X1@ }

X2# = Priority status for receive timeout:

0 = priority set to Send Data String command parameters;

1 = priority set to Configure Receive Timeout command parameters.

X2% = Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600, 115200

X2^ = Parity: Odd, Even, None, Mark, Space (only the first letter is required)

X2& = Data bits: 7, 8

X2* = Stop bits: 1, 2

X2( = Port type: 0 = RS-232; 1 = RS-422; 2 = RS-485

X3) = Flow control: Hardware, Software, None (only the first letter is needed)

X3! = Data pacing (specified in milliseconds between bytes): 0–1000 (default = 0 ms)

X3# = Password: allows a maximum length of 12 alpha numeric characters. Special characters are not allowed.

NUser password cannot be assigned if no administrator password exists and returns E14. If an admin password is cleared, then the user password is removed too.

IPL T S Series • Communication and Control

4-3

Image 43
Contents IP Link Ethernet Control Interfaces IPL T S SeriesSicherheitsanleitungen Deutsch PrecautionsSafety Instructions English Consignes de Sécurité FrançaisFCC Class a Notice IPL T S SeriesIi IPL T S Series Or on a rack Quick Start IPL T S SeriesOn a projector Under a deskQS-2 IPL T S Series Quick Start Preliminary Table of ContentsTable of Contents, cont’d One About This Manual IntroductionAbout the IPL T S Series Interface IPL T S6 FeaturesIntroduction, cont’d Two Mounting the IPL T S Interface Installation and OperationInstallation Overview IPL T S Series Installation and OperationVersaTools 19 1U Rack Shelf Mounting optionsRack mounting an IPL T S Series interface Mounting Type Kit PNFurniture mount kit for IPL T S2, S4, S6 Furniture or projector mountingFurniture mount kit for IPL T S1 Projector mount kit for IPL T S1Mounting the interface Rear Panel Features and CablingPreliminary PowerSerial Communication Ethernet/LANLink LED a lit green LED indicates a good LAN connection Pin Function RS-232 RS-422 RS-485 IPL T S Series InstallationUID # The unique user ID number MAC address of the unit for Front panel indicatorsOperation IdentificationLED is not lit, the connection speed is 10 Mbps Resetting the unitUnit later in this chapter for more information RX LEDs a green LED indicates data is being received byMode Activation Result Reset Mode Comparison/SummaryInstallation and Operation, cont’d Three Ethernet connection Connection and ConfigurationConnecting the Hardware IPL T S Series Connection and ConfigurationHold down the Reset button until the Power LED blinks twice Setting the Internet Protocol IP AddressRear panel of the unit ex 00-05-A6-01-0A-74 Advanced options of the Add Device dialog are displayed, Setting the IP address using Global ConfiguratorAdd Device dialog box opens see figure Enter a unique device name in the Display Name fieldIP address Subnet mask Default gateway blank Setting the IP address using embedded Web pagesInternet Protocol TCP/IP Properties dialog box Start All Programs Accessories Command Prompt Setting the IP address using the ARP commandArp sIP addressMAC address Click the Download GCSW2XX.exe button Configuration using Global ConfiguratorGlobal Configurator Configuration using Embedded Web PagesWeb server Password dialog box Connecting via the Web server pagesSystem Status ConfigurationSystem Settings IP Settings Date/Time SettingsPort Settings 12 System Settings screenEmail Alerts PasswordsFile Management Firmware UpgradeTo run DataViewer Configuration using DataViewerTo download DataViewer Scroll to the description of DataViewerDataViewer application opens see figure 19 Communication Setup dialog boxFour IPL T S Series Communication and Control Using the command/response tableCommunication and Control Programmer’s Guide for Telnet and Web BrowsersX1% = Domain name e.g., extron.com, icia.org Symbol definitionsCopyright information Password informationE17 System timed out E22 Busy Error responsesAscii to Decimal Conversion Table CommunicationBidirectional serial data port Series Communication and ControlCpnX!CtyX2  X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2X2%, X2, X2&, X2   X!*X2CYEthernet data port X5,X5#,X2X6 TC Series Communication and ControlFirmware version, part number and information requests X1! Series Communication and Control X4%SM  X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&  X4%CR X4, X4&  X1& ,X1% CM WX1$ %2CX1% CM IpmX1$ ,X1%  X4%,X7,X4&SM WX4%%2CX7%2CX4&SM X1$ ,X1% ,X7# ,X7$ CM IpmX1$ ,X1% ,X7# ,X7$X1#  X1@CNX1@  X1#CTX6$,X1$  X2@  X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$   X6$ EB X5@ Password and security settings X3# CA  X3# CU WX3# CURemap port designations Directories Stream files via Telnet or RS-232 Subnet mask is reset to IP address is reset toDiscussed in Resetting the Unit Server Side Includes SSI This example the N command is used to requestCustomization Custom Web pagesHref=index.html?cmd=xInput #1/a Query stringExample Code examples6b Browser view of previous Html source code Reserved characters URL encodingAdvanced Serial Port Control Serial pass-through redirect modeUnsafe characters To initiate direct port access using DataViewer Direct port access ports 2001 throughHardware connection Click OK. The DataViewer commands window opensTo end the direct access session, close DataViewer Serial BridgingIPL T S4 Serial bridge configurationPower connections TroubleshootingData connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories Serial, 10-pole captive screw Specifications, Part Numbers, AccessoriesSpecifications IPL T S Series Specifications, Part Numbers, AccessoriesOr VersaTools 1U, 3.5 deep rack shelf RSF 123, #60-190-20 Mounting Rack mountAccessories Part number Part Numbers and AccessoriesOptional accessories Included parts Replacement part NumberAppendix B Glossary GlossaryIPL T S Series Glossary IPL T S Series Glossary Extron’s Warranty Extron China Extron EuropeExtron Asia Extron Japan
Related manuals
Manual 29 pages 23.94 Kb

IPL T S Series specifications

The Extron IPL T SFI244 is a sophisticated control system that is designed to streamline the management and operation of audiovisual equipment in a variety of environments, including conference rooms, classrooms, and auditoriums. This model falls under the IPL T S Series, renowned for its superior performance and user-friendly interface, making it a popular choice for integrators and users alike.

One of the standout features of the IPL T SFI244 is its advanced interface. It boasts an intuitive touch panel that enables users to manage multiple devices from a single control point, significantly simplifying the AV experience. The system supports a wide range of functions, including source selection, volume control, and the management of lighting and screen mechanisms. This centralized control helps to enhance collaboration and communication, particularly in educational and corporate settings.

The IPL T SFI244 integrates seamlessly with a variety of Extron technologies, including the GlobalViewer Enterprise, providing real-time monitoring and management capabilities. This web-based software solution gives administrators the ability to control AV systems remotely, ensuring optimal performance and minimizing downtime.

Another key characteristic of the IPL T SFI244 is its versatility. It incorporates various input and output options, such as HDMI, VGA, and audio connections, to accommodate different audiovisual equipment. This flexibility allows for easy integration into existing setups, catering to diverse applications and user preferences.

In terms of design, the IPL T SFI244 is engineered with reliability and durability in mind. It is equipped with features that enhance its performance in professional environments, including programmable button layouts that can be customized by users. This personalization ensures that the control system meets specific operational requirements, further enhancing the user experience.

Furthermore, the IPL T SFI244 is built with energy efficiency in mind, utilizing technologies that reduce power consumption without compromising performance. This eco-friendly approach not only supports sustainability initiatives but also contributes to long-term cost savings for organizations.

In summary, the Extron IPL T SFI244 is a comprehensive control solution that combines advanced technology, user-friendly features, and robust performance. Its ability to integrate with various AV equipment, coupled with its customizable interface and reliability, makes it an excellent choice for a wide range of applications, paving the way for more efficient and effective audiovisual management.