Specifications, Part Numbers, Accessories

Specifications — IPI 101, IPI 104 Series

Audio — IPI 101, IPI 104, and MLC 226 IP

Speaker

1.4” (35.6 mm), 1-way, indoor

Frequency response

 

Line level output (MLC)...

20 Hz to 3.3 kHz, ±1 dB

Speaker output (IPI)

300 Hz to 3.3 kHz, -10 dB

Nominal sensitivity/IPI speaker output level

 

80 dB SPL, 300 mW, 3’ (1 m)

Processing

 

Audio format

PCM, µ-law companded

Sampling rate

8 kHz

Sample size

16 bit, µ-law companded to 8 bit

Audio latency

<100 ms

Audio input — IPI

 

Number/signal type

1 mono, via integrated electret microphone

Microphone gain

-30 dB to 0 dB, adjustable in 2 dB steps

N0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV 2 dBu

Audio output

Number/signal type

2 mono: 1 via MLC 226 IP, 1 via IPI

 

speaker

Line level (MLC)

-10 dBV (316 mVrms), unbalanced (via

 

3.5 mm captive screw connector, 2 pole)

Amplified speaker IPI

300 mW, continuous, 1% THD

Ethernet control interface

Ethernet control communications port

1 RJ-45 female connector

Ethernet data rate/transport bandwidth 80 kbps

Communications type

Half duplex

Ethernet protocol

TCP/IP (control), UDP (port 3121, audio),

 

Telnet

Program control

Extron’s control/configuration program

 

for Windows®

 

Extron’s Simple Instruction Set (SIS)

 

Microsoft® Internet Explorer, Telnet

A-2 IPI 100 Series, IPI 200 Series • Specifications, Accessories

Image 92
Contents User’s Manual MediaLink IP Intercom InterfacesPrecautions 安全须知 中文 This page has been intentionally left blank Quick Start Guide IPI 101, IPI IPI 100 Series, IPI 200 Series Quick Start Guide QS-1Quick Start Guide -­ IPI 101, IPI 104, cont’d QS-2 IPI 100 Series, IPI 200 Series Quick Start GuideQuick Start Guide IPI 201, IPI IPI 100 Series, IPI 200 Series Quick Start Guide QS-3This page has been intentionally left blank Table of Contents Table of Contents, cont’d One About this Manual About the IP Intercom ModulesTerms used in this manual Additional reference materialIPI 100 Series, IPI 200 Series Introduction Introduction, cont’d Features System RequirementsTwo UL Requirements Installing or Replacing Button LabelsIPI 100 Series, IPI 200 Series Installation IPI 100 Series, IPI 200 Series Installation IPI 100 AAP, IPI 200 AAP Series Installation MLC 226 IP AAPIPI 100 AAP, IPI 200 AAP Series Installation Installation, cont’d IPI Rear Panel Features and Cabling IPI 104 AAP, IPI 101 AAP Rear PanelAAP mounting screws These four screws are permanently Installation, cont’d Single PC-to-panel modeMLC Audio Connection Sample ApplicationsMultiple PC-to-panel mode Intercom user releases the button when done speakingInstallation, cont’d Panel-to-panel mode Intercom with amplifier mode TCP/IPMLC 226 IP Installation, cont’d Three High MED LOW IPI 100 Series, IPI 200 Series Operation Button OperationPush to talk operation Operation, cont’d Indication lightingButton Color Indication PI 100 AAP, IPI 200 AAP Series OperationFour Software System Requirements Installing the SoftwareIPI 100 Series, IPI 200 Series Configuration and Control Using the Software an Overview Configuration and Control, cont’d IP Intercom HelpDesk screen before configurationParts of the Main Screen Speaking to an intercom Making a group announcementIPI 100 Series, IPI 200 Series Configuration and Control Listening to an intercom Click the Play to Intercoms buttonHands-free operation No Incoming Calls is displayed when no calls are coming Select Advanced Settings... from the Intercom menu Tools menu Main Screen MenusFile menu Intercom menu Help menuSetting preferences General OptionsPush to Talk PTT Options These settings affect Configuring the IPI Intercom System Startup Audio These controls affect what, if any, soundParts of the Configuration Utility screen Configuration Utility menus Tools menu Upload the Station Not Present Wave File to Intercom Setup procedure IPI 100 Series, IPI 200 Series Configuration and Control Configuration and Control, cont’d Recording an original message Changing the audio format of existing files IPI 100 Series, IPI 200 Series Configuration and Control Configuration and Control, cont’d Chapter Five IPI 201/204 SIS Programming and Control Host-to-IPI CommunicationsIPI-initiated Messages IPI 100 Series, IPI 200 Series SIS Programming and ControlPassword information Error responsesCommands and Reponses Error response referencesUsing the command/response tables IPI 201/204 SIS Programming, cont’dIPI 100 Series, IPI 200 Series Programming and Control Symbol definitions X1#= Local date and time format= off/ignore This could be as large as 10 digits Command Ascii Telnet URL Encoded Web Response Additional X20Description Programming and ControlStatus commands +X20X1!  ControlIPI 201/IPI 201/IPI 204 -Thu, 20 Jan 2005 IPI 100 Series, IPI 200 Series Cont’d IPI 201/204 SIS Programming X1@ CN Ipn X1@   CNIpnX4  X1@ or X4  X# CZ  X1# CT Ipt X1# X1#   X1$ CI  X3$ CXX3$ X1$  X1* or X1 CS  X1$ CG X2@ CV X2@X2@   X6$,X1$ EB Bmd X6$,X1$   X6$ EB WCC  X3# CA  X4!   X3# CU  IpuX4! CK  X5@ orRemapping port designations Directory commands Series, IPI 200 Series Programming and Control IPI 201/204SIS Programming, cont’d Stream Files via Telnet or RS-232 File handling commands Stream Files via Port DF Evt Tue, 01 Mar 2005 020307 GMT  1AE  0AE ZY AAppendix a IPI 100 Series, IPI 200 Series Specifications, Accessories Audio IPI 101, IPI 104, and MLC 226 IPAudio input IPI Audio outputGeneral Audio Audio inputControl relay Specifications, Part Numbers, Accessories, cont’d Accessories Included parts Replacement Part numberIncluded Parts IPI 101 AAP and IPI 104 AAP MediaLink Controllers, labels Part numberAmplifiers, cable, miscellany Part number Extron’s Warranty USA, Canada, South America Japan Central AmericaExtron Electronics. All rights reserved