(c)Copyright 2007, Extron Electronics, IPI 201 V1.00,
]
Mon Day, DD Mon YYYY HH:MM:SS
(c)Copyright 2007, Extron Electronics, IPI 204, V1.00,
]
Mon Day, DD Mon YYYY HH:MM:SS
Vx.xx is the firmware version number.
The IPI sends the boot and copyright messages under the following circumstances:
•If the IPI is off and an
•If the IPI is on, it sends the boot and copyright messages when you first open a Telnet connection to the IPI. You can see the day of the week, date, and time if the IPI is connected via Telnet, but not via
Additional messages may be sent by the IPI in response to front panel selections and volume adjustments and when scripts are executed during scheduled events.
Password information
The “]Password:” prompt requires a password (administrator level or user level) followed by a carriage return. The prompt is repeated if the correct password is not entered.
If the correct password is entered, the unit responds with
“]Login Administrator ]” or “]Login User]”, depending on the password entered. If passwords are the same for both administrator and user, the unit will default to administrator privileges.
Error responses
When the IPI receives a valid SIS command, it executes the command and sends a response to the host device. If the IPI is unable to execute the command because the command is invalid or it contains invalid parameters, it returns an error response to the host.
The error response codes and their descriptions are as follows:
E12 – Invalid port number
E13 – Invalid value (the number is out of range/too large)
E14 – Not valid for this configuration
IPI 100 Series, IPI 200 Series • SIS Programming and Control |