VIS Enable

The current state of VIS (Vertical Interval Switching) is indicated by the presence or absence of a checkmark next to VIS Enable on the Options menu. If a checkmark appears, VIS is enabled. If a check mark does not appear, VIS is disabled. To toggle VIS on or off, click VIS Enable with your mouse pointer.

Vertical interval switching requires a Genlock signal from a blackburst generator or similar device.

Enable Response

The current state of the view response option is indicated by the presence or absence of a checkmark next to Enable Response on the Options menu. If a check mark appears, you will be able to view responses from the switcher when using terminal communication (see Using Terminal Comm below). If a checkmark does not appear, you will not be able to view responses from the switcher. To toggle the view response option on or off, click Enable Response with your mouse pointer.

Using Terminal Comm

The Terminal window is used to view ICS100 commands as they are sent to the switcher, and to view responses as they are received from the switcher. To use the Terminal window, click on Terminal Comm from the Options menu. The Terminal window opens.

In addition to viewing commands that are sent and received from the ICS100 Control Program, the Terminal window also allows you to save macro commands or a communication session and recall it for repeated or future use. Refer to ICS100 Control Program Help for additional information on terminal communication.

Resetting the unit

1.From the Options menu, click on Reset Unit. A pullout menu appears.

2.To partially reset the switcher (restore all parameters to factory default, except input volume settings) select Partial Reset from the pull out menu.

3.To fully reset the switcher (restore all parameters to factory default) select Full Reset from the pull out menu.

ICS100 Control Program help

For information about program features, you can access the help program from within the ICS100 Control Program, click on the Help tab on the main screen, then select Help from the drop-down menu.

MSG Matrix Switchers • Windows-based Control Program

4-7

Image 29
Contents MSG0804 and MSG0808 Matrix SwitchersSafety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschRack mounting the MSG0808 Connecting the MSG0808Quick Start MSG0804 and MSG0808 Operation Quick Start MSG0804 and MSG0808, cont’dTable of Contents Table of Contents, cont’d Introduction OneMSG Matrix Switcher Features About the MSG Matrix SwitchersMSG Matrix Switchers Introduction IntroductionFlexible Control Options This page intentionally left blank Two InstallationMounting the Switcher InstallationMSG Matrix Switchers Installation Tabletop useVideo Inputs Video Outputs Rear Panel ConnectorsRS-485 Half Duplex Connection Installation, cont’dMSG0808 installation example Connecting the MSG0804 and MSG0808Audio input and output Installation, cont’dUnbalanced audio Balanced audioConnecting the external sync signal Vertical Interval SwitchingThis page intentionally left blank Operation ThreeOperation Front Panel FeaturesMSG Matrix Switchers Operation Preset configurations Connecting inputs with outputsFront Panel Operation Miscellaneous front panel functionsOperation, cont’d Selecting the switching level audio versions onlyReset to factory default Windows-based Control Program FourWindows-based Control Program, Cont’d Installing the Windows-based ICS100 Control SoftwareUsing the Software ICS100 Interface screen MSG switcher controls options Using the control panelAdjusting output volume levels Setting volume levelsDefining input icons and labels Creating a new patchICS100 Set Output Volume window Adjusting input volume levelsOpening the Options menu Setting and using presetsEnable Response VIS EnableUsing Terminal Comm Resetting the unitThis page intentionally left blank Five Remote ControlMSG Matrix Switchers Remote Control Remote ControlDip Switch Settings Using the command table Host-to-MSG Matrix Switcher CommunicationsAddressing commands Command Table Remote Control, cont’dSet-up commands Command DescriptionVolume commands Switching commandsSwitching levels audio models only Blank outputMute all outputs Stop volume ramp Preset commands Remote Control from a NetworkEnabling remote control of the switcher over a network Change input volume level globalICS100 Serial Port Server window Instructions for configuring the client remote PCAdjusting the response time Adjusting response timeStopping communication Stopping communications from the server PCPress this button first CTL120-2 IR Remote ControlRemote Control, cont’d AAppendix SpecificationsVideo SpecificationsVideo input Video outputSync MSG Matrix Switchers Specifications A-3Audio audio models only Audio inputControl/remote switcher Specifications MSG0804 and MSG0808MSG Matrix Switchers Specifications GeneralReference Information BAppendixUpdating the Firmware To update the firmwareReference Information MSG Matrix Switchers Reference Information Installing Custom Engraved NameplatesInstalling the custom nameplates Optional accessories MSG Matrix Switcher part numbersReference Information, cont’d Part NumbersAssorted connectors BNC connectors Plenum Seventeen Conductor Installation CablePre-cut cables Extron Part BNC-4 Mini HR CableThis page intentionally left blank FCC Class a Notice Extron’s Warranty Extron Electronics, USA