Extron electronic MSG0808, MSG0804 manual Remote Control, cont’d, Command Table, Set-up commands

Page 34

Remote Control, cont’d

Command Table

Set-up commands

 

Use these commands to configure the switcher. If you are using a third-party

 

control system, you should place these commands in the start-up section of the

 

program. You only need to send these commands to the switcher once.

 

 

Command

Description

 

Request information

[ARC]

Request for model and version information.

Reset comm port

 

[CPx@]

Resets the communications port to the factory default (9600

 

baud, 8-bit, 1 stop bit, no parity, and no flow control)

 

• Where x = 1

Query comm port

 

[CPx?]

Query the communications port for current settings

 

• Where x = 1

Configure comm port

[CPxbpsfd]

Configures the communications port for baud rate, flow

 

control, and duplex

 

• Where:

 

x = 1

 

b = 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600, 4 for

 

19200, and 5 for 38400

 

p = 0 (no parity)

 

s = 0 (1 stop bit)

 

f = 0 to disable flow control and 1 to enable flow control

 

(xOn/xOff)

 

d = 0 (full duplex) or 1 (half duplex)

 

Default is 9600 baud, 1 stop bit, 8 data bits, no parity, no flow control, and full duplex

Factory reset

 

[DFLTx]

Performs a factory reset. The partial reset will return I/O

 

configurations, volume levels, and serial set-up to factory

 

levels. The full reset will return all parameters (including

 

presets) to factory default levels.

 

• Where:

 

x = 0 for partial reset

 

x = 1 for for full reset

Front panel executive mode

[FPx]

Enable or disable front panel executive mode and request

 

current status.

 

• Where:

 

x = 0 to enable executive mode (no front panel operation)

 

x = 1 to disable executive mode

 

x = ? to request current state

 

x = (blank) to toggle the current state

Serial response enable

[RESx]

Enable or disable serial responses from the switcher.

 

• Where

 

x = 0 to disable

 

x = 1 to enable

 

 

5-4 MSG Matrix Switchers • Remote Control

Image 34
Contents Matrix Switchers MSG0804 and MSG0808Consignes de Sécurité Français PrecautionsSafety Instructions English Sicherheitsanleitungen DeutschQuick Start MSG0804 and MSG0808 Connecting the MSG0808Rack mounting the MSG0808 Quick Start MSG0804 and MSG0808, cont’d OperationTable of Contents Table of Contents, cont’d One IntroductionMSG Matrix Switchers Introduction About the MSG Matrix SwitchersMSG Matrix Switcher Features IntroductionFlexible Control Options This page intentionally left blank Installation TwoMSG Matrix Switchers Installation InstallationMounting the Switcher Tabletop useRear Panel Connectors Video Inputs Video OutputsInstallation, cont’d RS-485 Half Duplex ConnectionConnecting the MSG0804 and MSG0808 MSG0808 installation exampleUnbalanced audio Installation, cont’dAudio input and output Balanced audioVertical Interval Switching Connecting the external sync signalThis page intentionally left blank Three OperationMSG Matrix Switchers Operation Front Panel FeaturesOperation Front Panel Operation Connecting inputs with outputsPreset configurations Miscellaneous front panel functionsReset to factory default Selecting the switching level audio versions onlyOperation, cont’d Four Windows-based Control ProgramUsing the Software Installing the Windows-based ICS100 Control SoftwareWindows-based Control Program, Cont’d Using the control panel ICS100 Interface screen MSG switcher controls optionsDefining input icons and labels Setting volume levelsAdjusting output volume levels Creating a new patchAdjusting input volume levels ICS100 Set Output Volume windowSetting and using presets Opening the Options menuUsing Terminal Comm VIS EnableEnable Response Resetting the unitThis page intentionally left blank Remote Control FiveDip Switch Settings Remote ControlMSG Matrix Switchers Remote Control Addressing commands Host-to-MSG Matrix Switcher CommunicationsUsing the command table Set-up commands Remote Control, cont’dCommand Table Command DescriptionSwitching levels audio models only Switching commandsVolume commands Blank outputMute all outputs Stop volume ramp Enabling remote control of the switcher over a network Remote Control from a NetworkPreset commands Change input volume level globalInstructions for configuring the client remote PC ICS100 Serial Port Server windowStopping communication Adjusting response timeAdjusting the response time Stopping communications from the server PCCTL120-2 IR Remote Control Press this button firstRemote Control, cont’d Specifications AAppendixVideo input SpecificationsVideo Video outputAudio audio models only MSG Matrix Switchers Specifications A-3Sync Audio inputMSG Matrix Switchers Specifications Specifications MSG0804 and MSG0808Control/remote switcher GeneralBAppendix Reference InformationReference Information To update the firmwareUpdating the Firmware Installing the custom nameplates Installing Custom Engraved NameplatesMSG Matrix Switchers Reference Information Reference Information, cont’d MSG Matrix Switcher part numbersOptional accessories Part NumbersPre-cut cables Plenum Seventeen Conductor Installation CableAssorted connectors BNC connectors Extron Part BNC-4 Mini HR CableThis page intentionally left blank FCC Class a Notice Extron’s Warranty Extron Electronics, USA