Extron electronic MSG0804 Switching commands, Volume commands, Switching levels audio models only

Page 35

Switching commands

These commands can only initiate a one-input-to-one-output switch.

Switching levels (audio models only)

Switching levels consist of combinations of video (RGB), sync (HV), and audio boards. The three predefined switching levels include:

Level 1 = RGBHV and audio

Level 2 = RGBHV (no audio)

Level 3 = Audio only (no video or sync)

For commands that use these switching levels, refer to the Switching Commands

chart below.

 

 

 

Command

Description

 

 

Set switching level

 

 

 

[LVLx]

x = set switching level (1 to 3)

 

x = ? returns current switching level

Execute matrix switch

 

[MSxOooIii]

Executes a matrix switch of an input to an output for a

 

specific switching level.

 

• Where:

 

x = 1 - 3 for specific switching level.

 

oo = 01 - 04 (MSG0804) or 01 - 08 (MSG0808) for output.

 

ii = 00 - 08 for input (00 = blank)

Matrix switch current setting

 

 

 

[MSx?]

Returns the current connections for level x.

Matrix switch current output

 

[MsxOoo?]

Returns connections for specified output and level.

 

• Where:

 

x = switching level.

 

oo = 01 - 04 (MSG0804) or 01 - 08 (MSG0808)

Blank output

 

[BLANKoo]

Blanks a specific output.

 

• Where oo = 01 - 04 (MSG0804) or 01 - 08 (MSG0808)

 

 

Volume commands

Use these commands to control volume levels for both inputs and outputs. Input levels are typically adjusted to minimize drastic changes in volume when switching between inputs.

Command

Description

 

 

Mute/unmute

 

[MUTEoox]

Mute or unmute a specific output or request the current

 

status.

 

• Where:

oo = 01 - 04 (MSG0804) or 01 - 08 (MSG0808) for output. x = 0 to disable mute and 1 to enable mute.

x = ? to request the current state.

x = (blank) to toggle the current state.

MSG Matrix Switchers • Remote Control 5-5

Image 35
Contents MSG0804 and MSG0808 Matrix SwitchersSicherheitsanleitungen Deutsch PrecautionsSafety Instructions English Consignes de Sécurité FrançaisRack mounting the MSG0808 Connecting the MSG0808Quick Start MSG0804 and MSG0808 Operation Quick Start MSG0804 and MSG0808, cont’dTable of Contents Table of Contents, cont’d Introduction OneIntroduction About the MSG Matrix SwitchersMSG Matrix Switcher Features MSG Matrix Switchers IntroductionFlexible Control Options This page intentionally left blank Two InstallationTabletop use InstallationMounting the Switcher MSG Matrix Switchers InstallationVideo Inputs Video Outputs Rear Panel ConnectorsRS-485 Half Duplex Connection Installation, cont’dMSG0808 installation example Connecting the MSG0804 and MSG0808Balanced audio Installation, cont’dAudio input and output Unbalanced audioConnecting the external sync signal Vertical Interval SwitchingThis page intentionally left blank Operation ThreeOperation Front Panel FeaturesMSG Matrix Switchers Operation Miscellaneous front panel functions Connecting inputs with outputsPreset configurations Front Panel OperationOperation, cont’d Selecting the switching level audio versions onlyReset to factory default Windows-based Control Program FourWindows-based Control Program, Cont’d Installing the Windows-based ICS100 Control SoftwareUsing the Software ICS100 Interface screen MSG switcher controls options Using the control panelCreating a new patch Setting volume levelsAdjusting output volume levels Defining input icons and labelsICS100 Set Output Volume window Adjusting input volume levelsOpening the Options menu Setting and using presetsResetting the unit VIS EnableEnable Response Using Terminal CommThis page intentionally left blank Five Remote ControlMSG Matrix Switchers Remote Control Remote ControlDip Switch Settings Using the command table Host-to-MSG Matrix Switcher CommunicationsAddressing commands Command Description Remote Control, cont’dCommand Table Set-up commandsBlank output Switching commandsVolume commands Switching levels audio models onlyMute all outputs Stop volume ramp Change input volume level global Remote Control from a NetworkPreset commands Enabling remote control of the switcher over a networkICS100 Serial Port Server window Instructions for configuring the client remote PCStopping communications from the server PC Adjusting response timeAdjusting the response time Stopping communicationPress this button first CTL120-2 IR Remote ControlRemote Control, cont’d AAppendix SpecificationsVideo output SpecificationsVideo Video inputAudio input MSG Matrix Switchers Specifications A-3Sync Audio audio models onlyGeneral Specifications MSG0804 and MSG0808Control/remote switcher MSG Matrix Switchers SpecificationsReference Information BAppendixUpdating the Firmware To update the firmwareReference Information MSG Matrix Switchers Reference Information Installing Custom Engraved NameplatesInstalling the custom nameplates Part Numbers MSG Matrix Switcher part numbersOptional accessories Reference Information, cont’dExtron Part BNC-4 Mini HR Cable Plenum Seventeen Conductor Installation CableAssorted connectors BNC connectors Pre-cut cablesThis page intentionally left blank FCC Class a Notice Extron’s Warranty Extron Electronics, USA