Figure 5-1 — ICS100 Serial Port Server window

3.Make sure the Local IP, Port, Client IP, and Connection Status information is correct (you may need to check with your Network Administrator or IT group for this information). If the client PC is connected to the server, a Client IP address will be displayed and the Connection Status will show green (red if not connected).

4.The Inline Serial Server waits for the client PC on TCP/IP port 2001 (the factory default). If that port is already in use, you may change the number of the port (open the ICS100 Control Software Help file for instructions).

5.When the server has been connected and configured correctly, the client can be configured to connect to the server (check with your Network Administrator to secure log-on rights to the server).

Instructions for configuring the client (remote) PC:

1.Install the ICS100 Control Software program. See chapter 4, Windows-based Control Program, for information on installing the software.

2.Click the Windows Start button, then select Programs, then ICS100. The ICS100 (the “client”) launches.

3.Open a connection to the server as follows:

a.In the ICS100 Control Software, click on the Communications tab, then select Network from the drop-down menu. The Server Connection window opens.

Figure 5-2 — ICS100 Server Connection window

b.Enter the IP Address and Port number of the server PC.

c.Click OK. The connection is visible in the main window.

d.Click OK again. The client PC can now be used to control the switcher.

MSG Matrix Switchers • Remote Control 5-9

Image 39
Contents MSG0804 and MSG0808 Matrix SwitchersSicherheitsanleitungen Deutsch PrecautionsSafety Instructions English Consignes de Sécurité FrançaisConnecting the MSG0808 Quick Start MSG0804 and MSG0808Rack mounting the MSG0808 Operation Quick Start MSG0804 and MSG0808, cont’dTable of Contents Table of Contents, cont’d Introduction OneIntroduction About the MSG Matrix SwitchersMSG Matrix Switcher Features MSG Matrix Switchers IntroductionFlexible Control Options This page intentionally left blank Two InstallationTabletop use InstallationMounting the Switcher MSG Matrix Switchers InstallationVideo Inputs Video Outputs Rear Panel ConnectorsRS-485 Half Duplex Connection Installation, cont’dMSG0808 installation example Connecting the MSG0804 and MSG0808Balanced audio Installation, cont’dAudio input and output Unbalanced audioConnecting the external sync signal Vertical Interval SwitchingThis page intentionally left blank Operation ThreeFront Panel Features MSG Matrix Switchers OperationOperation Miscellaneous front panel functions Connecting inputs with outputsPreset configurations Front Panel OperationSelecting the switching level audio versions only Reset to factory defaultOperation, cont’d Windows-based Control Program FourInstalling the Windows-based ICS100 Control Software Using the SoftwareWindows-based Control Program, Cont’d ICS100 Interface screen MSG switcher controls options Using the control panelCreating a new patch Setting volume levelsAdjusting output volume levels Defining input icons and labelsICS100 Set Output Volume window Adjusting input volume levelsOpening the Options menu Setting and using presetsResetting the unit VIS EnableEnable Response Using Terminal CommThis page intentionally left blank Five Remote ControlRemote Control Dip Switch SettingsMSG Matrix Switchers Remote Control Host-to-MSG Matrix Switcher Communications Addressing commandsUsing the command table Command Description Remote Control, cont’dCommand Table Set-up commandsBlank output Switching commandsVolume commands Switching levels audio models only Mute all outputs Stop volume ramp Change input volume level global Remote Control from a NetworkPreset commands Enabling remote control of the switcher over a networkICS100 Serial Port Server window Instructions for configuring the client remote PCStopping communications from the server PC Adjusting response timeAdjusting the response time Stopping communicationPress this button first CTL120-2 IR Remote ControlRemote Control, cont’d AAppendix SpecificationsVideo output SpecificationsVideo Video inputAudio input MSG Matrix Switchers Specifications A-3Sync Audio audio models onlyGeneral Specifications MSG0804 and MSG0808Control/remote switcher MSG Matrix Switchers SpecificationsReference Information BAppendixTo update the firmware Reference InformationUpdating the Firmware Installing Custom Engraved Nameplates Installing the custom nameplatesMSG Matrix Switchers Reference Information Part Numbers MSG Matrix Switcher part numbersOptional accessories Reference Information, cont’dExtron Part BNC-4 Mini HR Cable Plenum Seventeen Conductor Installation CableAssorted connectors BNC connectors Pre-cut cablesThis page intentionally left blank FCC Class a Notice Extron’s Warranty Extron Electronics, USA