Termination resistors should only be turned on when operating in
Host-to-MSG Matrix Switcher Communications
Command | Description | |
|
| |
| Assigns an address from 01 to 98 to the unit. Address 00 is | |
[ADDRxx] | a broadcast address and address 99 is reserved for future | |
products. | ||
| ||
| - Where xx = 01 to 98 | |
|
| |
[ADDR@] | Removes an address from the unit. This is the factory | |
dafault setting. | ||
| ||
|
| |
[ADDR?] | Query the unit for a previously assigned address. | |
|
| |
| Connects the controller to the addressed unit. 00 is a | |
[CCxx] | broadcast address and will connect to all attached units. | |
| - Where xx is the address of the unit to be contacted. | |
|
|
All serial commands are applicable to both the MSG0804 and MSG0808, except where the number of outputs differs between the two switchers. The MSG Matrix Switchers accept serial control protocol commands through the
Addressing commands
In
The factory default for the MSG Matrix Switchers is no address. You must assign an address between 01 and 98. In addition, 00 is a broadcast address, and all connected units will perform the action commanded (no responses will be sent).
Using the command table
The command table is shown on the following pages. Lower case characters are acceptable in the command field only where indicated. Command and response examples are shown throughout the command table.
MSG Matrix Switchers • Remote Control |