Extron electronic MSG0804 manual Host-to-MSG Matrix Switcher Communications, Addressing commands

Page 33

Termination resistors should only be turned on when operating in RS-422/ RS-485 mode, and then only for the first and last units on a long serial line. The default switch settings are all OFF. In half-duplex mode, only turn on one of the termination resistors, as they are connected together by the cable.

Host-to-MSG Matrix Switcher Communications

Command

Description

 

 

 

Assigns an address from 01 to 98 to the unit. Address 00 is

[ADDRxx]

a broadcast address and address 99 is reserved for future

products.

 

 

- Where xx = 01 to 98

 

 

[ADDR@]

Removes an address from the unit. This is the factory

dafault setting.

 

 

 

[ADDR?]

Query the unit for a previously assigned address.

 

 

 

Connects the controller to the addressed unit. 00 is a

[CCxx]

broadcast address and will connect to all attached units.

 

- Where xx is the address of the unit to be contacted.

 

 

All serial commands are applicable to both the MSG0804 and MSG0808, except where the number of outputs differs between the two switchers. The MSG Matrix Switchers accept serial control protocol commands through the RS-232/RS-422/RS-485 port. These commands consist of one or more characters per command field. They require a beginning delimiter ([) and an ending delimiter (]).

Addressing commands

In RS-232 mode, there is no need to assign an address to the switcher, however, if you are using RS-422 or RS-485 mode with several devices connected in parallel to a single serial port, you will need to assign an address for each unit.

The factory default for the MSG Matrix Switchers is no address. You must assign an address between 01 and 98. In addition, 00 is a broadcast address, and all connected units will perform the action commanded (no responses will be sent).

Using the command table

The command table is shown on the following pages. Lower case characters are acceptable in the command field only where indicated. Command and response examples are shown throughout the command table.

MSG Matrix Switchers • Remote Control

5-3

Image 33
Contents MSG0804 and MSG0808 Matrix SwitchersSafety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschConnecting the MSG0808 Quick Start MSG0804 and MSG0808Rack mounting the MSG0808 Operation Quick Start MSG0804 and MSG0808, cont’dTable of Contents Table of Contents, cont’d Introduction OneMSG Matrix Switcher Features About the MSG Matrix SwitchersMSG Matrix Switchers Introduction IntroductionFlexible Control Options This page intentionally left blank Two InstallationMounting the Switcher InstallationMSG Matrix Switchers Installation Tabletop useVideo Inputs Video Outputs Rear Panel ConnectorsRS-485 Half Duplex Connection Installation, cont’dMSG0808 installation example Connecting the MSG0804 and MSG0808Audio input and output Installation, cont’dUnbalanced audio Balanced audioConnecting the external sync signal Vertical Interval SwitchingThis page intentionally left blank Operation ThreeFront Panel Features MSG Matrix Switchers OperationOperation Preset configurations Connecting inputs with outputsFront Panel Operation Miscellaneous front panel functionsSelecting the switching level audio versions only Reset to factory defaultOperation, cont’d Windows-based Control Program FourInstalling the Windows-based ICS100 Control Software Using the SoftwareWindows-based Control Program, Cont’d ICS100 Interface screen MSG switcher controls options Using the control panelAdjusting output volume levels Setting volume levelsDefining input icons and labels Creating a new patchICS100 Set Output Volume window Adjusting input volume levelsOpening the Options menu Setting and using presetsEnable Response VIS EnableUsing Terminal Comm Resetting the unitThis page intentionally left blank Five Remote ControlRemote Control Dip Switch SettingsMSG Matrix Switchers Remote Control Host-to-MSG Matrix Switcher Communications Addressing commandsUsing the command table Command Table Remote Control, cont’dSet-up commands Command DescriptionVolume commands Switching commandsSwitching levels audio models only Blank outputMute all outputs Stop volume ramp Preset commands Remote Control from a NetworkEnabling remote control of the switcher over a network Change input volume level globalICS100 Serial Port Server window Instructions for configuring the client remote PCAdjusting the response time Adjusting response timeStopping communication Stopping communications from the server PCPress this button first CTL120-2 IR Remote ControlRemote Control, cont’d AAppendix SpecificationsVideo SpecificationsVideo input Video outputSync MSG Matrix Switchers Specifications A-3Audio audio models only Audio inputControl/remote switcher Specifications MSG0804 and MSG0808MSG Matrix Switchers Specifications GeneralReference Information BAppendixTo update the firmware Reference InformationUpdating the Firmware Installing Custom Engraved Nameplates Installing the custom nameplatesMSG Matrix Switchers Reference Information Optional accessories MSG Matrix Switcher part numbersReference Information, cont’d Part NumbersAssorted connectors BNC connectors Plenum Seventeen Conductor Installation CablePre-cut cables Extron Part BNC-4 Mini HR CableThis page intentionally left blank FCC Class a Notice Extron’s Warranty Extron Electronics, USA