Extron electronic HSA 822 Installation, cont’d Cabling the Enclosure, Bottom panel features

Page 12

Installation, cont’d

Cabling the Enclosure

Bottom panel features

3

 

2

 

1

 

 

4

1

 

3

5

Figure 2-6 — HSA 822 enclosure underside connectors

1RJ-45 connectors — See Cabling the RJ-45 connectors below.

All RJ-45 connectors are teminated in accordance with the TIA/EIA 568 A standard.

2AC power connector — Connect this cord to the power source.

For US-domestic versions, this power cord is permanently connected to the HSA. Connect the power cord to a 125 VAC,

60 Hz, 10 A power source.

For international versions, this power cord is a removable IEC power cord. Connect the cord to a 220-250 V, 50/60 Hz, 10 A power source.

3Cable access holes

4Spare AAP panel screws

5Top panel height adjustment screw — See “Adjusting the height of the top surface” in chapter 3, “Maintenance and Modifications”.

Cabling the RJ-45 connectors

Plug one end of a CAT 5 or CAT 6 twisted pair (TP) cable into each of these RJ-45 female connectors. Connect the other end to

an appropriate telecommunications or data network or to an Extron TP product.

An RJ-11 (telephone) plug can be connected to the RJ-45 jack.

When cabling the AAP panels and the bottom panel, the bottom RJ-45 connectors match up with the AAP panel RJ-45 connectors as shown in figure 2-7. For example, match the AAP panel RJ-45 connector A1 with the underside RJ-45 connector A1, match A2 with A2, and so forth.

B1

A1

 

A2

B2

 

 

B1

 

B2

A1

A2

 

Figure 2-7 — HSA 822 RJ-45 connectors

If necessary have a qualified service person replace the connector icon on the AAP panel by prying the old icon off of the connector plug-in with a tweeker or small screwdriver (figure 2-8) and snapping a new icon in place.

Icon Labels

Figure 2-8 — Changing the connector icon

2-10 HSA 822 Hideaway® Enclosure • Installation

HSA 822 Hideaway® Enclosure • Installation 2-11

Image 12
Contents Hideaway Surface Access Enclosure HSAPrecautions Extron’s WarrantyPage Table of Contents Table of Contents, cont’d IntroductionHSA 822 Hideaway Enclosure Introduction About the HSA 822 Hideaway EnclosureInstallation FeaturesIntroduction, cont’d Installation Installation OverviewPreparing the Routing Template Other installation surface. Mark the location Place the routing template assembly on the table, centeredOnce the template assembly is positioned properly, secure Assembly to the table with C-clamps figureInstallation, cont’d Clean the HSA. Strong solvents will ruin someDo not use isopropyl alcohol or other solvents to FinishesInstallation, cont’d Cabling and Installing the AAPs Installation, cont’d Cabling the Enclosure Bottom panel featuresAn RJ-11 telephone plug can be connected to the RJ-45 jack Installation, cont’d Routing the AAP Cables BezelsMaintenance and Modifications ThreeMaintenance and Modifications Replacing an AAPMaintenance and Modifications, cont’d Replacing the Bezels Removing and Replacing the EnclosureMaintenance and Modifications, cont’d Replacing the Gas Lift Insert the shaft end of the replacement gas lift through Reconnect the interior AC power cablesWith the top panel bracket detached from the lifting Platform, the bracket will be floppy atop the gas liftAdjusting the height of the top surface Height adjustment locking screw slotsAdjusting the top surface level Reference InformationSpecifications Reference InformationPart Numbers GeneralTemplate, Replacement Parts, and Accessories Interface AccessoriesTop Plate Dimensions Reference Information, cont’d Included PartsPackaging for Shipment Reference Information, cont’dPackaging for Shipment Figure B-1 HSA 822 return kitFigure B-3 Installing protective strips Packaging for Shipment, Cont’dFigure B-6 Placing the HSA in the shipping carton Packaging for Shipment, Cont’d