Extron electronic HSA 822 user manual Maintenance and Modifications, Replacing an AAP

Page 15

Maintenance and Modifications

The HSA 822 surface mount enclosures can be modified in the future to replace an AAP. The most probable corrective maintenance procedures required are leveling the top surface and replacing the gas lift. Most of the maintenance procedures require removing the surface mount enclosure from the table.

Replacing an AAP

Replace one or more AAPs as follows:

 

 

 

 

 

Ensure that AC power is disconnected before

 

 

 

 

 

servicing the HSA unit.

1.

On the underside of the clamshell and in the enclosure, cut

 

the tie wraps that route the AAP cables out of the way.

2.

Remove the top and bottom screws on the right and left

 

sides of the AAP panel (figure 3-1). Retain the screws. Lift

 

the panel away from the enclosure as far as the connected

 

cables allow and then allow the panel to dangle,

 

supported by its connected cables.

 

 

 

The center screws on each side of the AAP panel do not

 

 

 

 

 

 

fasten the AAP panel in place. They secure the

 

 

 

AC power outlet.

 

 

 

Ensure that the edges of the AAP panels do not

 

CAUTION

 

 

 

 

 

 

scratch the finished surface of the top panel flange

 

 

 

 

 

or the furniture in which the HSA 822 is installed

 

 

 

 

 

when removing the panels.

Remove two screws ea. side.

INPUT

 

 

SELECT

COMPUTER

O

 

AUDI

Remove panel.

HSA822

Figure 3-1 — Removing the AAP panel

3.

Disconnect any cables from the rear of the AAPs that are

 

being replaced. If a cable is no longer required in your

 

system, carefully pull the cable through and out the

 

bottom of the surface mount enclosure and the clamshell.

4.

Remove the AAP(s) that you no longer want from the AAP

 

panel by unscrewing the nuts on the rear of the AAP panel

 

that secure the AAPs in place (figure 3-2).

 

 

 

 

#4-40 Nut w/ Captive

 

 

 

 

 

Washer

AAP Panel

 

 

 

 

 

 

 

 

 

 

Cable

S UT

 

 

 

HSA

 

INP

 

 

 

 

822

ELE

 

A

 

 

CT CO

MP

UD

IO

 

 

 

 

 

UTER

 

 

RGB 580xi SI AAP

Figure 3-2 — Mounting an AAP device

5.Cable the rear of the AAPs to be installed before attaching the AAPs to the enclosure. Route the cables through the hole in the underside of the surface mount enclosure and connect them to the rear of the AAPs. If applicable, refer to the cabling information in the documentation for the AAP.

6.

Insert each AAP’s screws through the holes in the AAP

 

opening of the AAP panel. Secure each AAP to the panel

 

with the provided captive washers and #4-40 nuts.

7.

Replace the AAP panel in the surface mount enclosure and

 

secure them in place with the screws removed in step 2. If

 

you lose an AAP panel screw, four spare screws are stored

 

in the underside of the enclosure (see figure 2-6 on

 

page 2-10).

8.

To prevent wear and tear caused by cable movement,

 

secure the AAP cables underneath the table. See

 

page 2-12,Routing the AAP Cables.

3-2 HSA 822 Hideaway® Enclosure • Maintenance and Modifications

HSA 822 Hideaway® Enclosure • Maintenance and Modifications 3-3

Image 15
Contents HSA Hideaway Surface Access EnclosureExtron’s Warranty PrecautionsPage Table of Contents Table of Contents, cont’d IntroductionHSA 822 Hideaway Enclosure About the HSA 822 Hideaway Enclosure IntroductionInstallation FeaturesIntroduction, cont’d Installation Installation OverviewPreparing the Routing Template Assembly to the table with C-clamps figure Other installation surface. Mark the locationPlace the routing template assembly on the table, centered Once the template assembly is positioned properly, secureFinishes Installation, cont’dClean the HSA. Strong solvents will ruin some Do not use isopropyl alcohol or other solvents toInstallation, cont’d Cabling and Installing the AAPs Installation, cont’d Cabling the Enclosure Bottom panel featuresAn RJ-11 telephone plug can be connected to the RJ-45 jack Bezels Installation, cont’d Routing the AAP CablesThree Maintenance and ModificationsReplacing an AAP Maintenance and ModificationsRemoving and Replacing the Enclosure Maintenance and Modifications, cont’d Replacing the BezelsMaintenance and Modifications, cont’d Replacing the Gas Lift Platform, the bracket will be floppy atop the gas lift Insert the shaft end of the replacement gas lift throughReconnect the interior AC power cables With the top panel bracket detached from the liftingHeight adjustment locking screw slots Adjusting the height of the top surfaceReference Information Adjusting the top surface levelGeneral SpecificationsReference Information Part NumbersReference Information, cont’d Included Parts Template, Replacement Parts, and AccessoriesInterface Accessories Top Plate DimensionsReference Information, cont’d Packaging for ShipmentFigure B-1 HSA 822 return kit Packaging for ShipmentPackaging for Shipment, Cont’d Figure B-3 Installing protective stripsFigure B-6 Placing the HSA in the shipping carton Packaging for Shipment, Cont’d
Related manuals
Manual 23 pages 6.66 Kb