Extron electronic HSA 822 user manual Maintenance and Modifications, cont’d

Page 17

Maintenance and Modifications, cont’d

 

 

 

 

 

The flanged edges of the top of the surface enclosure

 

 

 

 

 

are sharp when the HSA is removed from the table.

 

 

 

 

 

Exercise caution when handling to prevent personal

 

 

 

 

 

injury.

 

 

 

 

The flanged edges of the top of the surface enclosure

 

CAUTION

 

 

 

 

 

 

are bevelled to an ultra-fine thickness of less than

 

 

 

 

 

0.04 (4/100)" (approximately 1 mm). These edges

 

 

 

 

 

are soft and can be easily nicked or bent. Exercise

 

 

 

 

 

caution when handling and mounting the

 

 

 

 

 

enclosure. Mishandling can damage the appearance

 

 

 

 

 

of the enclosure.

 

 

 

 

 

The surfaces of the HSA enclosure have screws and

 

 

 

 

 

other protruding hardware that could damage fine

 

 

 

 

 

furniture. Do not rest the enclosure on unprotected

 

 

 

 

 

furniture.

8.

On the underside of the table, remove the two bolts that

 

secure the clamshell to the surface mount enclosure

 

(figure 3-4). Lift the enclosure out of the table.

9.

Remove and retain the four screws in the corners of each

 

side surface of the enclosure shroud “cube”. Remove the

 

two halves of the shroud.

 

 

 

You do not need to remove the screws in the center of

 

 

 

 

 

 

each side. They do not secure the shroud in any way;

 

 

 

rather, they provide structural support to the enclosure.

10. Perform the desired maintenance or modification procedure.

11. If the surface is not level or the top panel is not level with the flange, adjust the top surface. See Adjusting the Top Surface in this chapter.

12. Connect the appropriate cables to the rear of the AAPs installed on the AAP panels. Route the cables through the hole in the underside of the surface mount enclosure and connect them to the rear of the AAPs. Refer to the cabling information in the documentation for the AAP.

13. Snap the interior RJ-45 cable connectors onto the rear of the RJ-45 AAP panel bezel plug-ins in the locations identified by the tags.

Remove (16) screws.

Power Cord

RJ-45 Connectors

HSA 822

Enclosure

Shroud

Mounting

Surface

AAP Cables

Clamshell

Flat Washer

Full Thread

Mounting Bolts

RJ-45 Bezel

Plug-in in AAP

Panel

Figure 3-4 — Removing the HSA 822 from the table

3-6 HSA 822 Hideaway® Enclosure • Maintenance and Modifications

HSA 822 Hideaway® Enclosure • Maintenance and Modifications 3-7

Image 17
Contents HSA Hideaway Surface Access EnclosureExtron’s Warranty PrecautionsPage Table of Contents HSA 822 Hideaway Enclosure Table of Contents, cont’dIntroduction About the HSA 822 Hideaway Enclosure IntroductionIntroduction, cont’d InstallationFeatures Preparing the Routing Template InstallationInstallation Overview Place the routing template assembly on the table, centered Other installation surface. Mark the locationOnce the template assembly is positioned properly, secure Assembly to the table with C-clamps figureClean the HSA. Strong solvents will ruin some Installation, cont’dDo not use isopropyl alcohol or other solvents to FinishesInstallation, cont’d Cabling and Installing the AAPs An RJ-11 telephone plug can be connected to the RJ-45 jack Installation, cont’d Cabling the EnclosureBottom panel features Bezels Installation, cont’d Routing the AAP CablesThree Maintenance and ModificationsReplacing an AAP Maintenance and ModificationsRemoving and Replacing the Enclosure Maintenance and Modifications, cont’d Replacing the BezelsMaintenance and Modifications, cont’d Replacing the Gas Lift Reconnect the interior AC power cables Insert the shaft end of the replacement gas lift throughWith the top panel bracket detached from the lifting Platform, the bracket will be floppy atop the gas liftHeight adjustment locking screw slots Adjusting the height of the top surfaceReference Information Adjusting the top surface levelReference Information SpecificationsPart Numbers GeneralInterface Accessories Template, Replacement Parts, and AccessoriesTop Plate Dimensions Reference Information, cont’d Included PartsReference Information, cont’d Packaging for ShipmentFigure B-1 HSA 822 return kit Packaging for ShipmentPackaging for Shipment, Cont’d Figure B-3 Installing protective stripsFigure B-6 Placing the HSA in the shipping carton Packaging for Shipment, Cont’d
Related manuals
Manual 23 pages 6.66 Kb