Extron electronic Opening in the table for the HSA 822 should be, Furniture, Enclosure, Injury

Page 9

Installation, cont’d

Preparing the Table and Mounting the Enclosure

The preferred and recommended method for preparing the table is to use the appropriate Extron metal routing template and a router.

Alternatively, you can use a paper cut-out template (see appendix A, “Reference Information”) and a sabre saw or keyhole saw, but this method is not recommended.

Prepare the table as follows:

 

CAUTION

The opening in the table for the HSA 822 should be

 

 

 

cut only by licensed and bonded craftspeople.

 

 

 

Exercise care to prevent scarring or damaging the

 

 

 

furniture.

 

 

 

The routing templates for the various HSA models

 

 

 

are not interchangeable. If you use the wrong

 

 

 

template, you will cut an improperly-sized hole. If

 

 

 

you use a larger template than required, the cut will

 

 

 

result in gaps in the table surface on either side of

 

 

 

the enclosure.

 

 

 

The surfaces of the HSA enclosure have screws and

 

 

 

other protruding hardware that could damage fine

 

 

 

furniture. Do not rest the enclosure on unprotected

 

 

 

furniture.

 

 

The metal routing template is reusable. Do not discard

 

 

 

 

this template when the installation is complete. Save it

 

 

for future HSA 822 installations.

1.

Locate the desired mounting location on the tabletop or

 

other installation surface. Mark the location.

 

 

Ensure that only the wooden strips contact the

 

CAUTION

 

 

 

furniture. Failure to do so may mar the furniture.

2.

Place the routing template assembly on the table, centered

 

on the mounting location. Angle the template for the

 

optimum positioning. If necessary, use a square to ensure

 

that the template is properly positioned. Extron is not

 

responsible for improperly-positioned HSA products.

3.

Once the template assembly is positioned properly, secure

 

the assembly to the table with C-clamps (figure 2-2).

Figure 2-2 — Cutting the opening with a router

 

 

 

 

 

Wear safety glasses when operating the router.

 

 

 

 

 

Failure to comply can result in eye injury.

4.

Using a router with a 5/8" (or 16 mm) outside diameter

 

guide bushing and a 1/2" (or 12 mm or 12.7 mm) diameter

 

straight router bit, carefully cut the opening in the table

 

surface (figure 2-2).

5.

Remove the C-clamps and the routing template.

 

 

 

 

 

The flanged edges of the top of the surface enclosure

 

 

 

 

 

 

 

 

 

are sharp when the HSA is removed from the table.

 

 

 

 

 

Exercise caution when handling to prevent personal

 

 

 

 

 

injury.

 

 

 

The flanged edges of the top of the surface enclosure

 

CAUTION

 

 

 

 

 

 

are bevelled to an ultra-fine thickness of less than

0.04(4/100)" (approximately 1 mm). These edges are soft and can be easily nicked or bent. Exercise caution when handling and mounting the enclosure. Mishandling can damage the appearance of the enclosure.

2-4

HSA 822 Hideaway® Enclosure • Installation

HSA 822 Hideaway® Enclosure • Installation

2-5

Image 9
Contents HSA Hideaway Surface Access EnclosureExtron’s Warranty PrecautionsPage Table of Contents Table of Contents, cont’d IntroductionHSA 822 Hideaway Enclosure About the HSA 822 Hideaway Enclosure IntroductionInstallation FeaturesIntroduction, cont’d Installation Installation OverviewPreparing the Routing Template Place the routing template assembly on the table, centered Other installation surface. Mark the locationOnce the template assembly is positioned properly, secure Assembly to the table with C-clamps figureClean the HSA. Strong solvents will ruin some Installation, cont’dDo not use isopropyl alcohol or other solvents to FinishesInstallation, cont’d Cabling and Installing the AAPs Installation, cont’d Cabling the Enclosure Bottom panel featuresAn RJ-11 telephone plug can be connected to the RJ-45 jack Bezels Installation, cont’d Routing the AAP CablesThree Maintenance and ModificationsReplacing an AAP Maintenance and ModificationsRemoving and Replacing the Enclosure Maintenance and Modifications, cont’d Replacing the BezelsMaintenance and Modifications, cont’d Replacing the Gas Lift Reconnect the interior AC power cables Insert the shaft end of the replacement gas lift throughWith the top panel bracket detached from the lifting Platform, the bracket will be floppy atop the gas liftHeight adjustment locking screw slots Adjusting the height of the top surfaceReference Information Adjusting the top surface levelReference Information SpecificationsPart Numbers GeneralInterface Accessories Template, Replacement Parts, and AccessoriesTop Plate Dimensions Reference Information, cont’d Included PartsReference Information, cont’d Packaging for ShipmentFigure B-1 HSA 822 return kit Packaging for ShipmentPackaging for Shipment, Cont’d Figure B-3 Installing protective stripsFigure B-6 Placing the HSA in the shipping carton Packaging for Shipment, Cont’d