Extron electronic HSA 822 user manual Installation Overview, Preparing the Routing Template

Page 8

Installation

Installation Overview

Install and set up the HSA 822 as follows:

1If desired, install the optional RJ-45 to RJ-11 conversion kit(s) to replace one or more RJ-45 connectors with RJ-11 connectors. Refer to the RJ-45 to RJ-11 Conversion Kit manual.

2If desired, install the optional flexible conduit kit to replace the removable AC power cord. Refer to the Flexible Conduit Kit manual.

3If you have an unprepared mounting template, prepare the template. See “Preparing the Routing Template” on the next page.

4Cut a hole in the surface where the enclosure will be installed and install the enclosure. The clamshell, a clamping and protective device, clamps the enclosure to the table. See “Preparing the Table and Mounting the Enclosure” on page 2-4.

5Run all cables necessary to support the AC and

RJ-45 connectors and all planned AAP connectors. Leave enough slack in the cables to connect them to the underside of the enclosure or to the rear of the AAPs before the AAPs are installed in the enclosure.

6Turn off all of the equipment to be connected. Ensure that the equipment connected to the RJ-45 connectors and the connections for any AAPs are all turned off and disconnected from the power source.

7If applicable, connect cables to the rear connectors on the AAPs to be installed in the HSA 822. Install the desired AAPs on the AAP panel of the enclosure. See “Cabling and Installing the AAPs” on page 2-8.

8Connect the power and RJ-45 cables to the underside of the enclosure. See “Cabling the Enclosure” on page 2-10.

9Route and secure the AAP cables inside the clamshell. See “Routing the AAP Cables” on page 2-12.

10If present, peel the protective coating from the top surface.

11Connect power cords and turn on the devices that connect to the surface access enclosure.

Preparing the Routing Template

Extron provides a metal routing template for the HSA 822 at no charge. The HSA 822 template is part #70-191-01. Extron recommends using this template as a guide to cut the hole in the table where the HSA will be installed.

 

 

The metal routing template is reusable. Do not discard

 

 

this template when the installation is complete. Save it

 

 

for future HSA 822 installations.

1.

Cut 1/2" x 4" strips of soft, finished lumber long enough to

 

span the distance between the desired installation location

 

on the table or other mounting surface and the edges of

 

the table (figure 2-1).

 

Mounting

 

Surface

 

Edge

Minimum

Wood

4 Screws

Strips

 

Wood Strip

 

Height

 

4" / 10.2 cm

Mounting

Routing Template

Surface

 

Edge

 

Wood Thickness 0.5" / 1.3 cm

Figure 2-1 — Prepared routing template

These strips raise the routing template above the mounting surface to provide room for the router’s collar, protect the mounting surface, and extend the reach of the routing template so that it can be clamped to the edge of the surface.

2.

Using four or more short wood screws, secure the routing

 

template to the lumber strips.

 

 

Do not allow the wood screws to protrude through

 

CAUTION

 

 

the bottom of the wooden strips. Protruding screws

 

 

will mar the table when the template is used.

2-2

HSA 822 Hideaway® Enclosure • Installation

HSA 822 Hideaway® Enclosure • Installation

2-3

Image 8
Contents Hideaway Surface Access Enclosure HSAPrecautions Extron’s WarrantyPage Table of Contents HSA 822 Hideaway Enclosure Table of Contents, cont’dIntroduction Introduction About the HSA 822 Hideaway EnclosureIntroduction, cont’d InstallationFeatures Preparing the Routing Template InstallationInstallation Overview Other installation surface. Mark the location Place the routing template assembly on the table, centeredOnce the template assembly is positioned properly, secure Assembly to the table with C-clamps figureInstallation, cont’d Clean the HSA. Strong solvents will ruin someDo not use isopropyl alcohol or other solvents to FinishesInstallation, cont’d Cabling and Installing the AAPs An RJ-11 telephone plug can be connected to the RJ-45 jack Installation, cont’d Cabling the EnclosureBottom panel features Installation, cont’d Routing the AAP Cables BezelsMaintenance and Modifications ThreeMaintenance and Modifications Replacing an AAPMaintenance and Modifications, cont’d Replacing the Bezels Removing and Replacing the EnclosureMaintenance and Modifications, cont’d Replacing the Gas Lift Insert the shaft end of the replacement gas lift through Reconnect the interior AC power cablesWith the top panel bracket detached from the lifting Platform, the bracket will be floppy atop the gas liftAdjusting the height of the top surface Height adjustment locking screw slotsAdjusting the top surface level Reference InformationSpecifications Reference InformationPart Numbers GeneralTemplate, Replacement Parts, and Accessories Interface AccessoriesTop Plate Dimensions Reference Information, cont’d Included PartsPackaging for Shipment Reference Information, cont’dPackaging for Shipment Figure B-1 HSA 822 return kitFigure B-3 Installing protective strips Packaging for Shipment, Cont’dFigure B-6 Placing the HSA in the shipping carton Packaging for Shipment, Cont’d